Effect of Electrocautery and Laser Treatment on the Composition and Morphology of Surface-Modified Titanium Implants

被引:3
|
作者
Lee, Jin-Seok [1 ]
Son, Keunbada [2 ]
Hwang, Sung-Min [1 ]
Son, Young-Tak [2 ,3 ]
Kim, Yong-Gun [1 ]
Suh, Jo-Young [1 ]
Hwang, Jun Ho [4 ]
Kwon, Sung-Min [4 ]
Lee, Jong Hoon [4 ]
Kim, Hyun Deok [5 ]
Lee, Kyu-Bok [6 ]
Lee, Jae-Mok [1 ]
机构
[1] Kyungpook Natl Univ, Sch Dent, Dept Periodontol, Daegu 41940, South Korea
[2] Kyungpook Natl Univ, Adv Dent Device Dev Inst A3DI, Daegu 41940, South Korea
[3] Kyungpook Natl Univ, Grad Sch, Dept Dent Sci, Daegu 41940, South Korea
[4] Kyungpook Natl Univ, Inst Adv Convergence Technol, Daegu 41061, South Korea
[5] Kyungpook Natl Univ, Sch Elect Engn, Daegu 41566, South Korea
[6] Kyungpook Natl Univ, Sch Dent, Dept Prosthodont, Daegu 41940, South Korea
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 11期
基金
新加坡国家研究基金会;
关键词
dental implant; electrocautery treatment; laser treatment; surface roughness;
D O I
10.3390/bioengineering10111251
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The purpose of this study was to investigate the effects of different peri-implantitis treatment methods (Er,Cr:YSGG laser, diode laser, and electrocautery) on various titanium implant surfaces: machined; sandblasted, large-grit, and acid-etched; and femtosecond laser-treated surfaces. Grade 4 titanium (Ti) disks, with a diameter of 10 mm and a thickness of 1 mm, were fabricated and treated using the aforementioned techniques. Subsequently, each treated group of disks underwent different peri-implantitis treatment methods: Er,Cr:YSGG laser (Biolase, Inc., Foothill Ranch, CA, USA), diode laser (Biolase, Inc., Foothill Ranch, CA, USA), and electrocautery (Ellman, Hicksville, NY, USA). Scanning electron microscopy, energy-dispersive X-ray spectroscopy, and wettability were used to characterize the chemical compositions and surfaces of the treated titanium surfaces. Significant changes in surface roughness were observed in both the electrocautery (Sa value of machined surface = 0.469, SLA surface = 1.569, femtosecond laser surface = 1.741, and p = 0.025) and Er,Cr:YSGG laser (Ra value of machined surface = 1.034, SLA surface = 1.380, femtosecond laser surface = 1.437, and p = 0.025) groups. On femtosecond laser-treated titanium implant surfaces, all three treatment methods significantly reduced the surface contact angle (control = 82.2 degrees, diode laser = 74.3 degrees, Er,Cr:YSGG laser = 73.8 degrees, electrocautery = 76.2 degrees, and p = 0.039). Overall, Er,Cr:YSGG laser and electrocautery treatments significantly altered the surface roughness of titanium implant surfaces. As a result of surface composition after different peri-implantitis treatment methods, relative to the diode laser and electrocautery, the Er,Cr:YSGG laser increased oxygen concentration. The most dramatic change was observed after Er:Cr;YSGG laser treatment, urging caution for clinical applications. Changes in surface composition and wettability were observed but were not statistically significant. Further research is needed to understand the biological implications of these peri-implantitis treatment methods.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Effect of surface treatment on unalloyed titanium implants: Spectroscopic analyses
    Kilpadi, DV
    Raikar, GN
    Liu, J
    Lemons, JE
    Vohra, Y
    Gregory, JC
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1998, 40 (04): : 646 - 659
  • [2] Surface morphology characterization of laser-induced titanium implants: lesson to enhance osseointegration process
    Tavakoli J.
    Khosroshahi M.E.
    Biomedical Engineering Letters, 2018, 8 (03) : 249 - 257
  • [3] The Potential of a Surface-Modified Titanium Implant with Tetrapeptide for Osseointegration Enhancement
    Syam, Syamsiah
    Wu, Chia-Jen
    Lan, Wen-Chien
    Ou, Keng-Liang
    Huang, Bai-Hung
    Lin, Yu-Yeong
    Saito, Takashi
    Tsai, Hsin-Yu
    Chuo, Yen-Chun
    Yen, Ming-Liang
    Liu, Chung-Ming
    Hou, Ping-Jen
    APPLIED SCIENCES-BASEL, 2021, 11 (06):
  • [4] Titanium surface modified by hydroxyapatite coating for dental implants
    Hung, Kuo-Yung
    Lo, Sung-Cheng
    Shih, Chung-Sheng
    Yang, Yung-Chin
    Feng, Hui-Ping
    Lin, Yi-Chih
    SURFACE & COATINGS TECHNOLOGY, 2013, 231 : 337 - 345
  • [5] The Influence of Implant Design on Bone Remodeling around Surface-Modified Southern Implants®
    Vandeweghe, Stefan
    Cosyn, Jan
    Thevissen, Eric
    Teerlinck, Johan
    De Bruyn, Hugo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (05) : 655 - 662
  • [6] Mechanical properties, surface morphology and stability of a modified commercially pure high strength titanium alloy for dental implants
    Elias, Carlos Nelson
    Fernandes, Daniel Jogaib
    Resende, Celso R. S.
    Roestel, Jochen
    DENTAL MATERIALS, 2015, 31 (02) : E1 - E13
  • [7] Unlocking the potential: laser surface modifications for titanium dental implants
    Kolarovszki, Bela
    Ficsor, Szabolcs
    Frank, Dorottya
    Katona, Krisztian
    Soos, Balazs
    Turzo, Kinga
    LASERS IN MEDICAL SCIENCE, 2024, 39 (01)
  • [8] Insights into Surface Treatment Methods of Titanium Dental Implants
    Guo, Cecilia Yan
    Tang, Alexander Tin Hong
    Matinlinna, Jukka Pekka
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2012, 26 (1-3) : 189 - 205
  • [9] Influence of surface treatment by laser irradiation on bacterial adhesion on surfaces of titanium implants and their alloys: Systematic review
    Simoes, Isadora Gazott
    dos Reis, Andrea Candido
    Valente, Mariana Lima da Costa
    SAUDI DENTAL JOURNAL, 2023, 35 (02) : 111 - 124
  • [10] Fatigue and cyclic deformation behaviour of surface-modified titanium alloys in simulated physiological media
    Leinenbach, C
    Eifler, D
    BIOMATERIALS, 2006, 27 (08) : 1200 - 1208