Geometry modification of a vertical shell-and-tube latent heat thermal energy storage system using a framed structure with different undulated shapes for the phase change material container during the melting process

被引:23
|
作者
Ben Khedher, Nidhal [1 ,2 ]
Biswas, Nirmalendu [3 ]
Togun, Hussein [4 ]
Mohammed, Hayder I. [5 ]
Mahdi, Jasim M. [6 ]
Ibrahem, Raed Khalid [7 ]
Talebizadehsardari, Pouyan [8 ]
机构
[1] Univ Hail, Coll Engn, Dept Mech Engn, Hail City 81451, Saudi Arabia
[2] Univ Monastir, Lab Thermal Energet Syst Studies LESTE, Natl Sch Engn Monastir, Monastir, Tunisia
[3] Jadavpur Univ, Dept Power Engn, Kolkata 700106, India
[4] Univ Thi Qar, Coll Engn, Dept Biomed Engn, Thi Qar 64001, Iraq
[5] Univ Garmian, Coll Educ, Dept Phys, Kurdistan 46021, Kalar, Iraq
[6] Univ Baghdad, Dept Energy Engn, Baghdad 10071, Iraq
[7] Al Farahidi Univ, Dept Med Instrumentat Engn, Baghdad 10015, Iraq
[8] Univ Nottingham, Power Elect Machines & Control PEMC Res Grp, Nottingham, England
关键词
Thermal energy storage; Undulated surface; Framed-structure; Melting; Phase change materials; NATURAL-CONVECTION; POWER-SYSTEM; PCM; PERFORMANCE; CONDUCTIVITY; GRAPHITE; ANNULUS; SOLIDIFICATION; EFFICIENCY; FINS;
D O I
10.1016/j.est.2023.108365
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study aims to modify the melting performance of a vertical latent heat double-pipe heat exchanger by geometry modification of the phase change material (PCM) container. To modify the configuration of the PCM container placed in the outer tube, a framed structure is embedded in the inner surface of the outer tube. Different framed structures i.e. smooth, arc-shaped, reverse arc-shaped, and zigzag-shaped structures are examined and compared with that of the unframed enclosure. Moreover, different numbers of pitches are also examined. The results show that the melting duration drops by almost 55 % and the thermal energy storage rate improves by 115 % using a smooth framed structure for the PCM container compared with that of using an unframed structure. The thermal energy storage rate and melting time are-9.5 W and 244.4 min, respectively, for the system using an unframed structure. The analysis of the pitch number for the zigzag-shaped structure reveals that increasing the number of pitches from 0 to 11 enhances the thermal energy storage rate by 36.5 %. The evaluation of different shapes of the framed structure shows that the case with reverse arc-shaped structure is the most enhanced unit which has the thermal energy storage rate of-34 W and melting time of 63.15 min heated by water at the Reynolds number 1000 and inlet water temperature of 50 degrees C. The sensitivity analysis of the HTF characteristics reveals that by increasing the Re from 1000 to 2000, the thermal energy storage rate increases by around 6 W. Furthermore, by increasing the inlet temperature of HTF from 50 degrees C to 55 degrees C, the thermal energy storage rate enhances by around 10 W. This paper shows the capability of geometry modification in enhancing the thermal energy storage rate of the systems.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Revolutionizing the latent heat storage: Boosting discharge performance with innovative undulated phase change material containers in a vertical shell-and-tube system
    Sultan, Hakim S.
    Mohammed, Hayder, I
    Biswas, Nirmalendu
    Togun, Hussein
    Ibrahem, Raed Khalid
    Mahdi, Jasim M.
    Yaici, Wahiba
    Keshmiri, Amir
    Talebizadehsardari, Pouyan
    JOURNAL OF COMPUTATIONAL DESIGN AND ENGINEERING, 2024, 11 (02) : 122 - 145
  • [2] Evaluation of different melting performance enhancement structures in a shell-and-tube latent heat thermal energy storage system
    Ge, Ruihuan
    Li, Qi
    Li, Chuan
    Liu, Qing
    RENEWABLE ENERGY, 2022, 187 : 829 - 843
  • [3] Experimental investigation during the melting process of a vertical and horizontal tube-in-shell Latent Heat Energy Storage System
    Panisilvam, Jeggathishwaran
    Tay, N. H. S.
    Wang, Peng Cheng
    JOURNAL OF ENERGY STORAGE, 2022, 55
  • [4] A comparative study of thermal behaviour of a horizontal and vertical shell-and-tube energy storage using phase change materials
    Seddegh, Saeid
    Wang, Xiaolin
    Henderson, Alan D.
    APPLIED THERMAL ENGINEERING, 2016, 93 : 348 - 358
  • [5] Effects of shell modifications and operational parameters on melting uniformity of a vertical multi-section shell-and-tube latent heat thermal energy storage unit
    Chen, Lanxin
    Fan, Aiwu
    JOURNAL OF ENERGY STORAGE, 2022, 55
  • [6] NUMERICAL ANALYSIS OF MELTING OF NANOENHANCED PHASE CHANGE MATERIAL IN LATENT HEAT THERMAL ENERGY STORAGE SYSTEM
    Kashani, Sina
    Lakzian, Esmail
    Lakzian, Kazem
    Mastiani, Mohammad
    THERMAL SCIENCE, 2014, 18 : S335 - S345
  • [7] Multi-objective optimization of a phase change material-based shell-and-tube heat exchanger for cold thermal energy storage: experiments and numerical modeling
    Bianco, Nicola
    Fragnito, Andrea
    Iasiello, Marcello
    Mauro, Gerardo Maria
    Mongibello, Luigi
    APPLIED THERMAL ENGINEERING, 2022, 215
  • [8] Experimental study on melting enhancement of phase change material in a vertical cylindrical latent heat storage using a short concentric helical heat transfer tube
    Punniakodi, Banumathi Munuswamy Swami
    Senthil, Ramalingam
    JOURNAL OF ENERGY STORAGE, 2021, 41
  • [9] Design and optimization of a vertical shell-and-tube latent heat thermal energy storage system via discontinuous fins
    Tang, Songzhen
    Song, Yuling
    Liu, Pinwei
    Wu, Xuehong
    Xu, Yanyan
    Thou, Junjie
    Li, Xiuzhen
    RENEWABLE ENERGY, 2025, 243
  • [10] NUMERICAL INVESTIGATION OF MELTING PROCESS IN HORIZONTAL SHELL-AND-TUBE PHASE CHANGE MATERIAL STORAGE CONSIDERING DIFFERENT HTF CHANNEL GEOMETRIES
    Ajarostaghi, Seyed Soheil Mousavi
    Delavar, Mojtaba Aghajani
    Dolati, Adel
    HEAT TRANSFER RESEARCH, 2017, 48 (16) : 1515 - 1529