Diagnostic Accuracy of Office Blood Pressure Measurement and Home Blood Pressure Monitoring for Hypertension Screening Among Adults: Results From the IDH Study

被引:5
作者
Mizuno, Hiroyuki [1 ,2 ]
Choi, Eunhee [1 ]
Kario, Kazuomi [2 ]
Muntner, Paul [3 ]
Fang, Chloe L. [1 ]
Liu, Justin [1 ]
Sangapalaarachchi, Dona N. [1 ]
Lam, Michael [1 ]
Yano, Yuichiro [4 ,5 ]
Schwartz, Joseph E. [6 ,7 ]
Shimbo, Daichi [1 ,8 ]
机构
[1] Columbia Univ, Irving Med Ctr, Columbia Hypertens Ctr & Lab, New York, NY USA
[2] Jichi Med Univ, Sch Med, Div Cardiovasc Med, Tochigi, Japan
[3] Univ Alabama Birmingham, Sch Publ Hlth, Dept Epidemiol, Birmingham, AL USA
[4] Shiga Univ Med Sci, Noncommunicable Dis NCD Epidemiol Res Ctr, Shiga, Japan
[5] Duke Univ, Dept Family Med & Community Hlth, Durham, NC USA
[6] Columbia Univ, Irving Med Ctr, Ctr Behav Cardiovasc Hlth, New York, NY USA
[7] SUNY Stony Brook, Dept Psychiat & Behav Sci, Stony Brook, NY USA
[8] Columbia Univ, Irving Med Ctr, 60 Haven Ave,Off Suite B234, New York, NY 10032 USA
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2023年 / 12卷 / 24期
基金
美国国家卫生研究院;
关键词
ambulatory blood pressure monitoring; home blood pressure monitoring; hypertension screening; office blood pressure measurement; INTERNATIONAL DATABASE; MASKED HYPERTENSION; CLINICAL-PRACTICE; EUROPEAN-SOCIETY; TASK-FORCE; WHITE-COAT; VALIDATION; PREVENTION;
D O I
10.1161/JAHA.123.030150
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundUsing high awake blood pressure (BP; >= 130/80 mm Hg) on ambulatory BP monitoring (ABPM) as a reference, the purpose of this study was to determine the accuracy of high office BP (>= 130/80 mm Hg) at an initial visit and high confirmatory office BP (>= 130/80 mm Hg), and separately, high home BP (>= 130/80 mm Hg) among participants with high office BP (>= 130/80 mm Hg) at an initial office visit.Methods and ResultsThe accuracy of office BP measurements using the oscillometric method for detecting high BP on ABPM was determined among 379 participants with complete office BP and ABPM data in the IDH (Improving the Detection of Hypertension) study. For detecting high BP on ABPM, the accuracy of high confirmatory office BP using the oscillometric method and, separately, high home BP was also determined among the subgroup of 122 participants with high office BP at an initial visit and complete home BP monitoring data. High office BP had moderate sensitivity (0.61 [95% CI, 0.53-0.68]) and high specificity (0.85 [95% CI, 0.80-0.90]) for high awake BP. High confirmatory office BP and high home BP had moderate sensitivity (0.69 [95% CI, 0.59-0.79] and 0.79 [95% CI, 0.71-0.87], respectively) and low and moderate specificity (0.44 [95% CI, 0.27-0.61] and 0.72 [95% CI, 0.56-0.88], respectively).ConclusionsMany individuals with high BP on ABPM do not have high office BP. Confirmatory office BP and home blood pressure monitoring also had limited ability to identify individuals with high BP on ABPM.
引用
收藏
页数:11
相关论文
共 32 条
[1]   Is Isolated Nocturnal Hypertension A Reproducible Phenotype? [J].
Abdalla, Marwah ;
Goldsmith, Jeff ;
Muntner, Paul ;
Diaz, Keith M. ;
Reynolds, Kristi ;
Schwartz, Joseph E. ;
Shimbo, Daichi .
AMERICAN JOURNAL OF HYPERTENSION, 2016, 29 (01) :33-38
[2]   Predicting Out-of-Office Blood Pressure in a Diverse US Population [J].
Bellows, Brandon K. ;
Xu, Jingyu ;
Sheppard, James P. ;
Schwartz, Joseph E. ;
Shimbo, Daichi ;
Muntner, Paul ;
McManus, Richard J. ;
Moran, Andrew E. ;
Bryant, Kelsey B. ;
Cohen, Laura P. ;
Bress, Adam P. ;
King, Jordan B. ;
Shikany, James M. ;
Green, Beverly B. ;
Yano, Yuichiro ;
Clark, Donald, III ;
Zhang, Yiyi .
AMERICAN JOURNAL OF HYPERTENSION, 2022, 35 (06) :533-542
[3]   Differences in night-time and daytime ambulatory blood pressure when diurnal periods are defined by self-report, fixed-times, and actigraphy: Improving the Detection of Hypertension study [J].
Booth, John N., III ;
Muntner, Paul ;
Abdalla, Marwah ;
Diaz, Keith M. ;
Viera, Anthony J. ;
Reynolds, Kristi ;
Schwartz, Joseph E. ;
Shimbo, Daichi .
JOURNAL OF HYPERTENSION, 2016, 34 (02) :235-243
[4]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[5]   Cardiovascular Events and Mortality in White Coat Hypertension A Systematic Review and Meta-analysis [J].
Cohen, Jordana B. ;
Lotito, Michael J. ;
Trivedi, Usha K. ;
Denker, Matthew G. ;
Cohen, Debbie L. ;
Townsend, Raymond R. .
ANNALS OF INTERNAL MEDICINE, 2019, 170 (12) :853-+
[6]   Short-Term Reproducibility of Masked Hypertension Among Adults Without Office Hypertension [J].
Cohen, Laura P. ;
Schwartz, Joseph E. ;
Pugliese, Daniel N. ;
Anstey, D. Edmund ;
Christian, Jessica P. ;
Jou, Stephanie ;
Muntner, Paul ;
Shimbo, Daichi ;
Bello, Natalie A. .
HYPERTENSION, 2020, 76 (04) :1169-1175
[7]   Validation of the Omron M7 (HEM-780-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol [J].
Coleman, Andrew ;
Steel, Stephen ;
Freeman, Paul ;
de Greeff, Annemarie ;
Shennan, Andrew .
BLOOD PRESSURE MONITORING, 2008, 13 (01) :49-54
[8]  
Guirguis-Blake J, 2021, Report No.: 20-05265-EF-1
[9]   Screening for Hypertension in Adults: Updated Evidence Report and Systematic Review for the US Preventive Services Task Force [J].
Guirguis-Blake, Janelle M. ;
Evans, Corinne V. ;
Webber, Elizabeth M. ;
Coppola, Erin L. ;
Perdue, Leslie A. ;
Weyrich, Meghan Soulsby .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 325 (16) :1657-1669
[10]   Screening for Hypertension in Adults: US Preventive Services Task Force Reaffirmation Recommendation Statement [J].
Krist, Alex H. ;
Davidson, Karina W. ;
Mangione, Carol M. ;
Cabana, Michael ;
Caughey, Aaron B. ;
Davis, Esa M. ;
Donahue, Katrina E. ;
Doubeni, Chyke A. ;
Kubik, Martha ;
Li, Li ;
Ogedegbe, Gbenga ;
Pbert, Lori ;
Silverstein, Michael ;
Stevermer, James ;
Tseng, Chien-Wen ;
Wong, John B. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 325 (16) :1650-1656