Estimation of Effective Dose in Monte Carlo Simulation Method for CT Coronary Angiography Patients

被引:0
|
作者
Sarma, Arnabjyoti Deva [1 ]
Singha, Mrinal Kanti [1 ,2 ,3 ]
Sharma, Jibon [2 ,3 ]
Kashyap, Manash Pratim [4 ]
机构
[1] Assam downtown Univ, Dept Radiol, Gauhati, Assam, India
[2] Down Town Hosp, Gauhati, Assam, India
[3] Gauhati Med Coll, State Canc Inst, Gauhati, Assam, India
[4] Assam Down Town Univ, Dept Stat, Gauhati, Assam, India
来源
INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH | 2023年 / 13卷 / 02期
关键词
Radiation; Computed Tomography; Effective Dose; Angiography; Monte Carlo Simulation; COMPUTED-TOMOGRAPHY EXAMINATIONS; DIAGNOSTIC REFERENCE LEVELS; MULTISLICE;
D O I
10.22376/ijlpr.2023.13.2.L194-L201
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Computed tomography (CT) scans of Coronary Angiography have significantly aided in the diagnosis of disorders of the coronary artery. In contrast to other radiological examinations, the patient's radiation exposure is notably higher. This study aimed to optimize the radiation dose and estimate the adequate amount in computed tomography (CT) for coronary angiography. A total of 380 patients were referred to the Primus Diagnostic Centre and Heath City Hospital, Guwahati Assam, during the study with coronary artery disturbances. Data on the technical parameters used in CT procedures were taken in 2022. The aim and study's objective was Organ and surface dose to specific radiosensitive organs (Chest) estimation using software imPACT 1.0.4 from National Radiological Protection Board (NRPB) SR250 Monte Carlo dataset. The study population (n = 380) comprised 190 men and 190 women with an average age of 29 to 75 years. The Mean +/- SD of BMI and ED are 22.42 +/- 1.06 and 21.57 +/- 4.27 respectively. The mean DLP is 854.67, and the mean ED is 21.57. The effective doses for males (13-27) mSv were in females (13-29) mSv. This study was a pioneer in presenting actual amounts of CT examinations in Assam because other countries have already started with more advanced CT procedures, such as dosages for paediatrics, coronary angiography and CT fluoroscopy. With this study, there may be more opportunities to create complex new studies or enhance the data from related studies that may be done in future work. The high precision with minimum risk, the current study can be considered as the need of the hour.
引用
收藏
页码:L194 / L201
页数:8
相关论文
共 50 条
  • [31] ESTIMATION OF PATIENT EFFECTIVE DOSE FROM 131I USING MONTE CARLO CALCULATION
    Jokic, Vesna Spasic
    Orlic, Milan
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 1669 - 1673
  • [32] Minimizing Radiation Dose for Coronary CT Angiography
    Vorobiof, Gabriel
    Achenbach, Stephan
    Narula, Jagat
    CARDIOLOGY CLINICS, 2012, 30 (01) : 9 - +
  • [33] Estimating Specific Patient Organ Dose for Chest CT Examinations with Monte Carlo Method
    Yang, Yang
    Zhuo, Weihai
    Zhao, Yiyang
    Xie, Tianwu
    Wang, Chuyan
    Liu, Haikuan
    APPLIED SCIENCES-BASEL, 2021, 11 (19):
  • [34] Monte Carlo dose index estimation in computed tomography
    Ati, Moncef
    Bouamrane, Rachid
    Addi, Djamel
    Maroc, Fatima Zohra
    Mecheret, Fatima Zohra
    AIMS BIOENGINEERING, 2020, 7 (04): : 224 - 235
  • [35] Monte Carlo simulation of single beam dose profile
    LIU Xiaowei
    WEN Guanghao
    LI Mianfeng(Zhongshan University
    NuclearScienceandTechniques, 1999, (02) : 87 - 90
  • [36] Modeling scattered radiation from dose compensator in CT by Forced Detection Monte Carlo simulation
    Bazargani, Negar
    Thompson, Richard A.
    Yagil, Yoad
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [37] Assessment of organ dose for adult undergoing CT examinations: Comparison of three software applications using Monte Carlo simulation
    Hakme, Maria
    Francis, Ziad
    Rizk, Chadia
    Fares, Georges
    APPLIED RADIATION AND ISOTOPES, 2025, 220
  • [38] Verification of organ doses calculated by a dose monitoring software tool based on Monte Carlo Simulation in thoracic CT protocols
    Guberina, Nika
    Suntharalingam, Saravanabavaan
    Nassenstein, Kai
    Forsting, Michael
    Theysohn, Jens
    Wetter, Axel
    Ringelstein, Adrian
    ACTA RADIOLOGICA, 2018, 59 (03) : 322 - 326
  • [39] A Monte Carlo simulation for the estimation of patient dose in rest and stress cardiac computed tomography with a 320-detector row CT scanner
    Geleijns, Jacob
    Joemai, Raoul M. S.
    Cros, Maria
    Hernandez-Giron, Irene
    Calzado, Alfonso
    Dewey, Marc
    Salvado, Marcal
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 1029 - 1034
  • [40] Effective dose estimation during conventional and CT urography
    Alzimami, K.
    Sulieman, A.
    Omer, E.
    Suliman, I. I.
    Alsafi, K.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 154 - 157