Image-guided navigation system for minimally invasive total hip arthroplasty (MITHA) using an improved position-sensing marker

被引:5
作者
Xie, Xianzhong [1 ]
Zhu, Mingzhu [1 ]
He, Bingwei [1 ]
Xu, Jie [2 ]
机构
[1] Fuzhou Univ, Sch Mech Engn, Fuzhou 350108, Fujian, Peoples R China
[2] Fujian Prov Hosp, Dept Orthoped Surg, Fuzhou 350013, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Surgery navigation; Minimally invasive total hip arthroplasty; Tracking; Point-based registration; Position-sensing marker; SURGICAL NAVIGATION; DYNAMIC NAVIGATION; POSE ESTIMATION; ACCURACY; TRACKING; REGISTRATION; PLACEMENT; TOOL;
D O I
10.1007/s11548-023-02861-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeMinimally invasive total hip arthroplasty (MITHA) is a treatment for hip arthritis, and it causes less tissue trauma, blood loss, and recovery time. However, the limited incision makes it difficult for surgeons to perceive the instruments' location and orientation. Computer-assisted navigation systems can help improve the medical outcome of MITHA. Directly applying existing navigation systems for MITHA, however, suffers from problems of bulky fiducial marker, severe feature-loss, multiple instruments tracking confusion, and radiation exposure. To tackle these problems, we propose an image-guided navigation system for MITHA using a novel position-sensing marker.MethodsA position-sensing marker is proposed to serve as the fiducial marker with high-density and multi-fold ID tags. It results in less feature span and enables the use of ID for each feature, overcoming the problem of bulky fiducial markers and multiple instruments tracking confusion. And the marker can be recognized even when a large part of locating features is obscured. As for the elimination of intraoperative radiation exposure, we propose a point-based method to achieve patient-image registration based on anatomical landmarks.ResultsQuantitative experiments are conducted to evaluate the feasibility of our system. The accuracy of instrument positioning is achieved at 0.33 +/- 0.18 mm, and that of patient-image registration is achieved at 0.79 +/- 0.15 mm. And qualitative experiments are also performed, verifying that our system can be used in compact surgical spatial volume and can address severe feature-loss and tracking confusion problems. In addition, our system does not require any intraoperative medical scans.ConclusionExperimental results indicate that our proposed system can assist surgeons without larger space occupations, radiation exposure, and extra incision, showing its potential application value in MITHA.
引用
收藏
页码:2155 / 2166
页数:12
相关论文
共 33 条
  • [1] Targeting repeatability of a less obtrusive surgical navigation procedure for total shoulder arthroplasty
    Aminov, Oded
    Regan, William
    Giles, Joshua W.
    Simon, Maciej J. K.
    Hodgson, Antony J.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (02) : 283 - 293
  • [2] A METHOD FOR REGISTRATION OF 3-D SHAPES
    BESL, PJ
    MCKAY, ND
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) : 239 - 256
  • [3] An enhanced marker pattern that achieves improved accuracy in surgical tool tracking
    Cartucho, Joao
    Wang, Chiyu
    Huang, Baoru
    Elson, Dan S.
    Darzi, Ara
    Giannarou, Stamatia
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2022, 10 (04) : 400 - 408
  • [4] Minimally invasive total hip arthroplasty - A prospective randomized study
    Chimento, GF
    Pavone, V
    Sharrock, N
    Kahn, B
    Cahill, J
    Sculco, TP
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (02) : 139 - 144
  • [5] Feasibility and Accuracy of Thoracolumbar Minimally Invasive Pedicle Screw Placement With Augmented Reality Navigation Technology
    Elmi-Terander, Adrian
    Nachabe, Rami
    Skulason, Halldor
    Pedersen, Kyrre
    Soderman, Michael
    Racadio, John
    Babic, Drazenko
    Gerdhem, Paul
    Edstrom, Erik
    [J]. SPINE, 2018, 43 (14) : 1018 - 1023
  • [6] Accuracy of Dynamic Navigation for Dental Implant Placement-Model-Based Evaluation
    Emery, Robert W.
    Merritt, Scott A.
    Lank, Kathryn
    Gibbs, Jason D.
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (05) : 399 - 405
  • [7] Spatial Position Measurement System for Surgical Navigation Using 3-D Image Marker-Based Tracking Tools With Compact Volume
    Fan, Zhencheng
    Chen, Guowen
    Wang, Junchen
    Liao, Hongen
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (02) : 378 - 389
  • [8] Forstner W., 1987, P INT C FAST PROC PH, P281
  • [9] Real-Time 6DOF Pose Estimation of Endoscopic Instruments Using Printable Markers
    Gadwe, Aniket
    Ren, Hongliang
    [J]. IEEE SENSORS JOURNAL, 2019, 19 (06) : 2338 - 2346
  • [10] Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation
    Kim, Terrence T.
    Drazin, Doniel
    Shweikeh, Faris
    Pashman, Robert
    Johnson, J. Patrick
    [J]. NEUROSURGICAL FOCUS, 2014, 36 (03)