Retinal nerve fibre layer thickness measured with SD-OCT in a population-based study: the Handan Eye Study

被引:10
作者
Wu, Jian [1 ,2 ]
Du, Yifan [1 ]
Lin, Caixia [1 ]
Zhu, Yingting [3 ]
Chen, Wei [2 ]
Pan, Qing [4 ,5 ]
Zhuo, Yehong [3 ]
Wang, Ningli [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Eye Ctr,Beijing Inst Ophthalmol, Beijing, Peoples R China
[2] Stanford Univ, Sch Med, Dept Ophthalmol, Palo Alto, CA 94304 USA
[3] Sun Yat Sen Univ, State Key Lab Ophthalmol, Zhongshan Ophthalm Ctr, Guangzhou, Peoples R China
[4] Sichuan Univ, West China Sch Publ Hlth, Dept Epidemiol & Biostat, Chengdu, Sichuan, Peoples R China
[5] Sichuan Univ, West China Hosp 4, Chengdu, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
retina; epidemiology; optic nerve; OPTICAL COHERENCE TOMOGRAPHY; SYSTEMIC PARAMETERS; GLAUCOMA; AGE; DETERMINANTS; ASSOCIATION; CHILDREN; CHINESE; NEURODEGENERATION; CLASSIFICATION;
D O I
10.1136/bjophthalmol-2021-320618
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To examine the normative profile of retinal nerve fibre layer (RNFL) thickness and ocular parameters based on spectral-domain optical coherence tomography (SD-OCT) and its associations with related parameters among the Chinese population. Methods This population-based cohort Handan Eye Study (HES) recruited participants aged >= 30 years. All subjects underwent a standardised ophthalmic examination. Peripapillary RNFL thickness was obtained using SD-OCT. Mixed linear models were adopted to evaluate the correlation of RNFL thickness with ocular parameters as well as systemic factors. R V.3.6.1 software was used for statistical analysis. Results 3509 subjects (7024 eyes) with the average age of 55.54 +/- 10.37 were collected in this analysis. Overall mean RNFL thickness measured was 113.46 +/- 10.90 mu m, and the thickest quadrant of parapapillary RNFL was the inferior quadrant, followed by the superior quadrant, the nasal quadrant and the temporal quadrant. In the multivariate linear regression model, thinner RNFL thickness was remarkable association with male (p<0.001), older age (p<0.001), increased body mass index (>30, p=0.018), absence of diabetes (p=0.009), history of cataract surgery (p=0.001), higher intraocular pressure (p=0.007), lower spherical equivalent (p<0.001) and increased axial length (p=0.048). Conclusions In non-glaucoma individuals, this difference of RNFL thickness in Chinese population should be noted in making disease diagnoses. Meanwhile, multiple ocular and systemic factors are closely related to the thickness of RNFL. Our findings further emphasise the need to demonstrate ethnic differences in RNFL thickness and the specificity of associated ocular and systemic factors, as well as to develop better normative databases worldwide.
引用
收藏
页码:1156 / 1164
页数:9
相关论文
共 65 条
  • [1] Normative Values of Peripapillary Retinal Nerve Fiber Layer Thickness in a Middle Eastern Population
    Al-Sa'ad, Mouna M.
    Shatarat, Amjad T.
    Amarin, Justin Z.
    Badran, Darwish H.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [2] Analysis of Normal Retinal Nerve Fiber Layer Thickness by Age, Sex, and Race Using Spectral Domain Optical Coherence Tomography
    Alasil, Tarek
    Wang, Kaidi
    Keane, Pearse A.
    Lee, Hang
    Baniasadi, Neda
    de Boer, Johannes F.
    Chen, Teresa C.
    [J]. JOURNAL OF GLAUCOMA, 2013, 22 (07) : 532 - 541
  • [3] Normative spectral domain optical coherence tomography data on macular and retinal nerve fiber layer thickness in Indians
    Appukuttan, Bindu
    Giridhar, Anantharaman
    Gopalakrishnan, Mahesh
    Sivaprasad, Sobha
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (03) : 316 - 321
  • [4] THE EFFECT OF AGE ON THE NERVE-FIBER POPULATION OF THE HUMAN OPTIC-NERVE
    BALAZSI, AG
    ROOTMAN, J
    DRANCE, SM
    SCHULZER, M
    DOUGLAS, GR
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1984, 97 (06) : 760 - 766
  • [5] Influence of cataract surgery on repeatability and measurements of spectral domain optical coherence tomography
    Bambo, Maria P.
    Garcia-Martin, Elena
    Otin, Sofia
    Sancho, Eva
    Fuertes, Isabel
    Herrero, Raquel
    Satue, Maria
    Pablo, Luis
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (01) : 52 - 58
  • [6] Retinal Nerve Fiber Layer Thickness in Normals Measured by Spectral Domain OCT
    Bendschneider, Delia
    Tornow, Ralf P.
    Horn, Folkert K.
    Laemmer, Robert
    Roessler, Christopher W.
    Juenemann, Anselm G.
    Kruse, Friedrich E.
    Mardin, Christian Y.
    [J]. JOURNAL OF GLAUCOMA, 2010, 19 (07) : 475 - 482
  • [7] Sensitivity and specificity of the StratusOCT for perimetric glaucoma
    Budenz, DL
    Michael, A
    Chang, RT
    McSoley, J
    Katz, J
    [J]. OPHTHALMOLOGY, 2005, 112 (01) : 3 - 9
  • [8] Determinants of normal retinal nerve fiber layer thickness measured by stratus OCT
    Budenz, Donald L.
    Anderson, Douglas R.
    Varma, Rohit
    Schuman, Joel
    Cantor, Louis
    Savell, Jonathan
    Greenfeld, David S.
    Patella, Vincent Michael
    Quigley, Harry A.
    Tielsch, James
    [J]. OPHTHALMOLOGY, 2007, 114 (06) : 1046 - 1052
  • [9] Design, methodology, and preliminary results of the follow-up of a population-based cohort study in rural area of northern China: Handan Eye Study
    Cao, Kai
    Hao, Jie
    Zhang, Ye
    Hu, Ai-Lian
    Yang, Xiao-Hui
    Li, Si-Zhen
    Wang, Bing-Song
    Zhang, Qing
    Hu, Jian-Ping
    Lin, Cai-Xia
    Yusufu, Mayinuer
    Wang, Ning-Li
    [J]. CHINESE MEDICAL JOURNAL, 2019, 132 (18) : 2157 - 2167
  • [10] Neuroretinal alterations in the early stages of diabetic retinopathy in patients with type 2 diabetes mellitus
    Carpineto, P.
    Toto, L.
    Aloia, R.
    Ciciarelli, V.
    Borrelli, E.
    Vitacolonna, E.
    Di Nicola, M.
    Di Antonio, L.
    Mastropasqua, R.
    [J]. EYE, 2016, 30 (05) : 673 - 679