A simple in situ method for optimizing settings for the Einzel lens elements in a focused ion beam

被引:0
作者
Swinford, Rich [1 ]
Sanchez, Erik [1 ]
机构
[1] Portland State Univ, Dept Phys, Portland, OR 97207 USA
关键词
OPTIMIZATION; DESIGN; BRIGHTNESS; COMPUTER;
D O I
10.1063/5.0099595
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Ion beams have had an incredible impact on research in the past couple of decades. One major reason for this is the continued development of systems having optimal beam currents that allows one to image more clearly at different spot sizes to include higher currents that allow for faster milling. The advancements for Focused ion beam (FIB) columns have developed rapidly due to the computational optimization of lens designs. However, once a system has been produced, the optimal column settings for these lenses may change or simply become obscure. Our work involves regaining this optimization with the newly applied values through a new algorithm, requiring hours, rather than the days or weeks that existing methods require. FIB columns frequently utilize electrostatic lens elements (normally two, condenser and objective). This work presents a method to quickly determine the optimal lens 1 (L1) values for large beam currents (& SIM;1 nA or greater), from a carefully acquired set of images without any detailed knowledge of the column geometry. Each set of images, acquired through a voltage sweep of the objective lens (L2) for a preset L1, is partitioned for its spectral content. The sharpest position at each spectral level is used to assess how close the preset L1 is to the optimal. This procedure is conducted for a range of L1 values, the optimal being the one having the smallest range in spectral sharpness. For a system that has suitable automation in place, the time to optimize L1 for a given beam energy and aperture diameter is & SIM;1.5 h or less. In addition to the technique for finding optimal condenser and objective lens parameters, an alternative peak determination method is presented.
引用
收藏
页数:15
相关论文
共 31 条
  • [1] Adelson E. H., 1984, RCA ENG, V29, P33
  • [2] Bhushan B., 1999, PROC IEEE MICR ELECT
  • [3] Probe current, probe size, and the practical brightness for probe forming systems
    Bronsgeest, M. S.
    Barth, J. E.
    Swanson, L. W.
    Kruit, P.
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2008, 26 (03): : 949 - 955
  • [4] Caustic-based approach to understanding bunching dynamics and current spike formation in particle bunches
    Charles, T. K.
    Paganin, D. M.
    Dowd, R. T.
    [J]. PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2016, 19 (10):
  • [5] Chen M., NO REFERENCE IMAGE B
  • [6] SIMION for the personal computer in reflection
    Dahl, DA
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 200 (1-3) : 3 - 25
  • [7] FEI Company, 1998, MAGN COL AL PN 21802
  • [8] Optimization of experimental operating parameters for very high resolution focused ion beam applications
    Gierak, J
    Vieu, C
    Schneider, M
    Launois, H
    Ben Assayag, G
    Septier, A
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1997, 15 (06): : 2373 - 2378
  • [9] Gonzalez R. C., 2020, DIGITAL IMAGE PROCES, VGlobal Edition
  • [10] 4th ed.