Device profile of EndoAnchors for aortic stent graft implantation: overview of their safety and efficacy

被引:1
作者
Curley, Daniel [1 ,2 ]
Sindhar, Jan [1 ]
Howard, Adam [2 ]
Zayed, Hany [1 ]
Saha, Prakash [1 ]
机构
[1] Kings Coll London, Sch Cardiovasc Med & Surg, Acad Dept Vasc Surg, Guys & St ThomasNHS Trust, London, England
[2] Colchester Gen Hosp, East Suffolk & North Essex NHS Fdn Trust, Dept Vasc Surg, Colchester, England
关键词
EndoAnchor; EndoStaple; EVAR; Heli-FX; Hostile neck; TEVAR; ENDOVASCULAR REPAIR; ANEURYSM REPAIR; NECK; SYSTEM; COMPLICATIONS; PREVENTION; MIGRATION; FIXATION; ENDOLEAK; TRIAL;
D O I
10.1080/17434440.2023.2221787
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
IntroductionEndovascular aneurysm repair (EVAR) and thoracic endovascular aneurysm repair (TEVAR) are established techniques to treat abdominal aortic aneurysms (AAA) and thoracic aortic aneurysms (TAA). However, there are limitations when challenging proximal neck anatomy is present. Heli-FX EndoAnchors have been used in addition to EVAR and TEVAR to improve proximal sealing of a stent-graft, but there are limited data available on their outcomes, safety, and efficacy.Areas CoveredThe properties and development of Heli-FX EndoAnchors are evaluated. The evidence of various clinical outcomes, safety, and efficacy is interrogated with the augmented use of Heli-FX EndoAnchors with EVAR or TEVAR.Expert OpinionChallenging proximal neck anatomy can be problematic during EVAR or TEVAR. EndoAnchors may be part of the solution - used either prophylactically or therapeutically. The safety and efficacy databases are building but long-term data are still not available for this device and there remains inadequate data to support its routine use. Judicious patient selection is still needed.
引用
收藏
页码:615 / 620
页数:6
相关论文
共 50 条
  • [31] Hemodynamic impact of abdominal aortic aneurysm stent-graft implantation-induced stenosis
    Aristokleous, Nicolas
    Kontopodis, Nikolaos G.
    Tzirakis, Konstantinos
    Ioannou, Christos V.
    Papaharilaou, Yannis
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (10) : 1523 - 1532
  • [32] Midterm results of aortic diameter outcomes after thoracic stent-graft implantation for aortic dissection: A multicenter study
    Gaxotte, Virginia
    Thony, Fredric
    Rousseau, Herve
    Lions, Christophe
    Otal, Philippe
    Willoteaux, Serge
    Rodiere, Mathieu
    Negaiwi, Ziad
    Joffre, Francis
    Beregi, Jean-Paul
    JOURNAL OF ENDOVASCULAR THERAPY, 2006, 13 (02) : 127 - 138
  • [33] Safety and effectiveness of the INCRAFT AAA Stent Graft for endovascular repair of abdominal aortic aneurysms
    Torsello, Giovanni
    Scheinert, Dierk
    Brunkwall, Jan S.
    Chiesa, Roberto
    Coppi, Gioachino
    Pratesi, Carlo
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) : 1 - 8
  • [34] Complete Ipsilateral Femoral Approach Using an Iliac Branch Device to Preserve a Sole Internal Iliac Artery After Aortic Stent-Graft Placement
    Riess, Henrik Christian
    Koelbel, Tilo
    Diener, Holger
    Heidemann, Franziska
    Debus, E. Sebastian
    Rohlffs, Fiona
    Tsilimparis, Nikolaos
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (05) : 800 - 802
  • [35] Efficacy and safety of single-branched stent graft in the treatment of type B aortic dissection: a meta-analysis of cohort studies
    Lin, Wenxiao
    Cai, Fuyuan
    Yan, Jinliang
    Lin, Xiaolei
    JOURNAL OF CARDIOTHORACIC SURGERY, 2025, 20 (01)
  • [36] Spontaneous Sealing of a Type Ia Endoleak after Ovation Stent Graft Implantation in a Patient with On-Label Aortic Neck Anatomy
    Pranteda, Chiara
    Sirignano, Pasqualino
    Capoccia, Laura
    Mansour, Wassim
    Montelione, Nunzio
    ANNALS OF VASCULAR SURGERY, 2016, 34 : 270.e19 - 270.e24
  • [37] Emergent Treatment of a Ruptured Thoracoabdominal Aortic Aneurysm by Off-Label Rescue Implantation of the Ovation Stent Graft in Nonagenarian Patients
    Pranteda, Chiara
    Sirignano, Pasqualino
    Fornelli, Federica
    Mansour, Wassim
    Montelione, Nunzio
    Capoccia, Laura
    Speziale, Francesco
    ANNALS OF VASCULAR SURGERY, 2017, 40 : 296.e15 - 296.e19
  • [38] Polymer Embolization and Anaphylactic Reaction during Implantation of an Ovation Stent Graft for Abdominal Aortic Aneurysm Exclusion
    Simonte, Gioele
    Isernia, Giacomo
    Fiorucci, Beatrice
    Paciaroni, Elisa
    Cieri, Enrico
    Rebonato, Alberto
    Lenti, Massimo
    ANNALS OF VASCULAR SURGERY, 2018, 50 : 298.e7 - 298.e11
  • [39] Anaphylactic Reaction During Implantation of the Ovation Stent-Graft System in a Patient With Abdominal Aortic Aneurysm
    Sfyroeras, George S.
    Moulakakis, Konstantinos G.
    Antonopoulos, Constantine N.
    Manikis, Dimitris
    Vasdekis, Spyridon N.
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (04) : 620 - 622
  • [40] Device profile of the Impella 5.0 and 5.5 system for mechanical circulatory support for patients with cardiogenic shock: overview of its safety and efficacy
    Pahuja, Mohit
    Hernandez-Montfort, Jaime
    Whitehead, Evan H.
    Kawabori, Masashi
    Kapur, Navin K.
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (01) : 1 - 10