Comparison of the pre-dilution and post-dilution methods for online hemodiafiltration

被引:1
|
作者
Kawai, Yusuke [1 ]
Maeda, Kazuya [2 ]
Moriishi, Misaki [1 ]
Kawanishi, Hideki [1 ]
Masaki, Takao [2 ]
机构
[1] Tsuchiya Gen Hosp, Akane Fdn, Dept Renal Dis & Blood Purificat Therapy, 3-30 Nakajimacho,Naka Ku, Hiroshima 7308655, Japan
[2] Hiroshima Univ Hosp, Dept Nephrol, 1-2-3 Kasumi,Minami Ku, Hiroshima 7348551, Japan
关键词
alpha; 1-microglobulin; Clear space; Online hemodiafiltration; Pre-dilution; Post-dilution; CHRONIC KIDNEY FAILURE; ALL-CAUSE MORTALITY; QUALITY-OF-LIFE; HEMODIALYSIS-PATIENTS; JAPANESE SOCIETY; DIALYSIS OUTCOMES; PRACTICE PATTERNS; THERAPIES; RISK; ALPHA(1)-MICROGLOBULIN;
D O I
10.1007/s10047-023-01391-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Online hemodiafiltration (OL-HDF) is a treatment modality using diffusion and ultrafiltration. There are two types of dilution methods in OL-HDF: pre-dilution, which is commonly provided in Japan, and post-dilution, which is commonly provided in Europe. The optimal OL-HDF method for individual patients is not well studied. In this study, we compared the clinical symptoms, laboratory data, spent dialysate, and adverse events of pre- and post-dilution OL-HDF. We conducted a prospective study of 20 patients who underwent OL-HDF between January 1, 2019 and October 30, 2019. Their clinical symptoms and dialysis efficacy were evaluated. All patients underwent OL-HDF every 3 months in the following sequence: first predilution, post-dilution, and second pre-dilution. We evaluated 18 patients for the clinical study and 6 for the spent dialysate study. No significant differences in spent dialysates regarding small and large solutes, blood pressure, recovery time, and clinical symptoms were observed between the pre- and post-dilution methods. However, the serum a1-microglobulin level in post-dilution OL-HDF was lower than that in pre-dilution OL-HDF (first pre- dilution: 124.8 +/- 14.3 mg/L; post-dilution: 116.6 +/- 13.9 mg/L; second pre-dilution: 125.8 +/- 13.0 mg/L; first pre-dilution vs. post-dilution, post-dilution vs. second predilution, and first pre-dilution vs. second pre-dilution: p = 0.001, p < 0.001, and p = 1.000, respectively). The most common adverse event was an increase in transmembrane pressure in the post-dilution period. Compared to pre-dilution, the postdilution method decreased the a1-microglobulin level; however, there were no significant differences in clinical symptoms or laboratory data.
引用
收藏
页码:48 / 56
页数:9
相关论文
共 45 条
  • [31] Evaluation of pre- and post-dilution continuous veno-venous hemofiltration on leukocyte and platelet function in patients with sepsis
    Chihara, Shinya
    Masuda, Yoshiki
    Tatsumi, Hiroomi
    Yamakage, Michiaki
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2019, 42 (01) : 9 - 16
  • [32] Post-Dilution High Convective Transport Improves Microinflammation and Endothelial Dysfunction Independently of the Technique
    Ariza, Francisco
    Merino, Ana
    Carracedo, Julia
    Antonia Alvarez de Lara, M.
    Crespo, Rodolfo
    Ramirez, Rafael
    Martin-Malo, Alejandro
    Aljama, Pedro
    BLOOD PURIFICATION, 2013, 35 (04) : 270 - 278
  • [33] Filter run time in CVVH: pre-versus post-dilution and nadroparin versus regional heparin-protamine anticoagulation
    van der Voort, PHJ
    Gerritsen, RT
    Kuiper, MA
    Egbers, PHM
    Kingma, WP
    Boerma, EC
    BLOOD PURIFICATION, 2005, 23 (03) : 175 - 180
  • [34] Patient- and treatment-related determinants of convective volume in post-dilution haemodiafiltration in clinical practice
    Penne, E. Lars
    van der Weerd, Neelke C.
    Bots, Michiel L.
    van den Dorpel, Marinus A.
    Grooteman, Muriel P. C.
    Levesque, Renee
    Nube, Menso J.
    ter Wee, Piet M.
    Blankestijn, Peter J.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2009, 24 (11) : 3493 - 3499
  • [35] Effects of High Blood Flow and High Pre-Dilution Replacement Fluid Rates on Small Solute Clearances in Hemofiltration
    Gashti, Casey N.
    Rodby, Roger A.
    Huang, Zhongping
    Gao, Dayong
    Zhang, Weiming
    BLOOD PURIFICATION, 2011, 32 (04) : 266 - 270
  • [36] Prospective randomised crossover trial comparing mixed and post-dilution haemodiafiltration: COMPare HDF
    Henson, Angela F.
    Arnold, Cherie
    Oliver, Veronica M.
    McStea, Megan E.
    Pollock, Robyn
    Carpenter, Sally M.
    Ellis, Carleen J.
    McCarthy, Kylee A.
    Mutatiri, Clyson
    See, Emily J.
    Cho, YeoungJee
    Johnson, David W.
    Hawley, Carmel M.
    RENAL SOCIETY OF AUSTRALASIA JOURNAL, 2023, 19 (02) : 77 - 78
  • [37] Post-Dilution on Line Haemodiafiltration with Citrate Dialysate: First Clinical Experience in Chronic Dialysis Patients
    Panichi, Vincenzo
    Fiaccadori, Enrico
    Rosati, Alberto
    Fanelli, Roberto
    Bernabini, Giada
    Scatena, Alessia
    Pizzarelli, Francesco
    SCIENTIFIC WORLD JOURNAL, 2013,
  • [38] Post-dialysis fatigue: Comparison of bicarbonate hemodialysis and online hemodiafiltration
    Bossola, Maurizio
    Monteburini, Tania
    Parodi, Emanuele
    Santarelli, Stefano
    Sirolli, Vittorio
    Cenerelli, Stefano
    Bonomini, Mario
    de Ninno, Grazia
    di Stasio, Enrico
    HEMODIALYSIS INTERNATIONAL, 2023, 27 (01) : 55 - 61
  • [39] Phosphate levels in patients treated with low-flux haemodialysis, pre-dilution haemofiltration and haemodiafiltration: post hoc analysis of a multicentre, randomized and controlled trial
    Locatelli, Francesco
    Altieri, Paolo
    Andrulli, Simeone
    Sau, Giovanna
    Bolasco, Piergiorgio
    Pedrini, Luciano A.
    Basile, Carlo
    David, Salvatore
    Gazzanelli, Luanna
    Tampieri, Guido
    Isola, Elisabetta
    Marzolla, Onofrio
    Memoli, Bruno
    Ganadu, Marino
    Reina, Ernesto
    Bertoli, Silvio
    Ferrara, Rocco
    Casu, Domenica
    Logias, Francesco
    Tarchini, Renzo
    Mattana, Giovanni
    Passaghe, Mario
    Fundoni, Gianfranco
    Villa, Giuseppe
    Di Iorio, Biagio Raffaele
    Pontoriero, Giuseppe
    Zoccali, Carmine
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 (06) : 1239 - 1246
  • [40] Long term variation of serum levels of uremic toxins in patients treated by post-dilution high volume on-line hemodiafiltration in comparison to standard low-flux bicarbonate dialysis: results from the REDERT study
    Panichi, Vincenzo
    Rocchetti, Maria Teresa
    Scatena, Alessia
    Rosati, Alberto
    Migliori, Massimiliano
    Pizzarelli, Francesco
    Gesualdo, Loreto
    JOURNAL OF NEPHROLOGY, 2017, 30 (04) : 583 - 591