Early diagnosis of coronary microvascular dysfunction by myocardial contrast stress echocardiography

被引:7
|
作者
Zhang, Jucheng [1 ,2 ]
Ma, Minwen [3 ]
Li, Huajun [4 ]
Pu, Zhaoxia [4 ]
Liu, Haipeng [5 ]
Huang, Tianhai [1 ]
Cheng, Huan [6 ]
Gong, Yinglan [7 ]
Chu, Yonghua [1 ]
Wang, Zhikang [1 ]
Jiang, Jun [4 ]
Xia, Ling [6 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 2, Sch Med, Dept Clin Engn, Hangzhou 310009, Peoples R China
[2] Key Lab Med Mol Imaging Zhejiang Prov, Hangzhou 310009, Peoples R China
[3] Zhejiang Univ, Affiliated Hosp 1, Sch Med, Dept Clin Engn, Hangzhou 310009, Peoples R China
[4] Zhejiang Univ, Affiliated Hosp 2, Sch Med, Dept Cardiol, Hangzhou 310009, Peoples R China
[5] Coventry Univ, Res Ctr Intelligent Healthcare, Coventry, England
[6] Zhejiang Univ, Inst Biomed Engn, Key Lab Biomed Engn, Minist Educ, Hangzhou 310027, Peoples R China
[7] Zhejiang Univ, Inst Wenzhou, Wenzhou 325036, Peoples R China
关键词
coronary microvascular dysfunction; myocardial contrast echocardiography; coronary flow reserve; myocardial ischemia; myocardial perfusion; ISCHEMIC-HEART-DISEASE; FLOW RESERVE; ANGINA; PATHOPHYSIOLOGY; PROGRESS;
D O I
10.3934/mbe.2023339
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Coronary microvascular dysfunction (CMD) is one of the basic mechanisms of myocardial ischemia. Myocardial contrast echocardiography (MCE) is a bedside technique that utilises microbubbles which remain entirely within the intravascular space and denotes the status of microvascular perfusion within that region. Some pilot studies suggested that MCE may be used to diagnose CMD, but without further validation. This study is aimed to investigate the diagnostic performance of MCE for the evaluation of CMD. MCE was performed at rest and during adenosine triphosphate stress. ECG triggered real-time frames were acquired in the apical 4-chamber, 3-chamber, 2-chamber, and long-axis imaging planes. These images were imported into Narnar for further processing. Eighty-two participants with suspicion of coronary disease and absence of significant epicardial lesions were prospectively investigated. Thermodilution was used as the gold standard to diagnose CMD. CMD was present in 23 (28%) patients. Myocardial blood flow reserve (MBF) was assessed using MCE. CMD was defined as MBF reserve < 2. The MCE method had a high sensitivity (88.1%) and specificity (95.7%) in the diagnosis of CMD. There was strong agreement with thermodilution (Kappa coefficient was 0.727; 95% CI: 0.57-0.88, p < 0.001). However, the correlation coefficient (r = 0.376; p < 0.001) was not high.
引用
收藏
页码:7845 / 7858
页数:14
相关论文
共 50 条
  • [1] Early detection of coronary microvascular endothelial dysfunction using intravenous myocardial contrast echocardiography
    Huang, XB
    Liu, YL
    Wu, PS
    Zha, DG
    Luo, Y
    Chen, XL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 385A - 385A
  • [2] Integrating myocardial metabolic imaging and stress myocardial contrast echocardiography to improve the diagnosis of coronary microvascular diseases in rabbits
    Wang, Guodong
    Li, Xiaohong
    Zhao, Jiaxin
    Chen, Shangke
    Qin, Yongde
    Guan, Lina
    Mu, Yuming
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (08)
  • [3] Myocardial perfusion echocardiography and coronary microvascular dysfunction
    Barletta, Giuseppe
    Del Bene, Maria Riccarda
    WORLD JOURNAL OF CARDIOLOGY, 2015, 7 (12): : 861 - 874
  • [4] Coronary Microvascular Dysfunction by Myocardial Contrast Echocardiography in Nonelderly Patients Referred for Computed Tomographic Coronary Angiography
    Taqui, Sahar
    Ferencik, Maros
    Davidson, Brian P.
    Belcik, J. Todd
    Moccetti, Federico
    Layoun, Michael
    Raber, Jacob
    Turker, Mitchell
    Tavori, Hagai
    Fazio, Sergio
    Lindner, Jonathan R.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2019, 32 (07) : 817 - 825
  • [5] Transient Myocardial Ischemia During Acetylcholine-Induced Coronary Microvascular Dysfunction Documented by Myocardial Contrast Echocardiography
    Ong, Peter
    Athanasiadis, Anastasios
    Mahrholdt, Heiko
    Shah, Benoy N.
    Sechtem, Udo
    Senior, Roxy
    CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (01) : 153 - 155
  • [6] Microvascular structural correlates of myocardial contrast echocardiography in patients with coronary artery disease and ventricular dysfunction.
    Shimoni, S
    Frangogiannis, NG
    Aggeli, CJ
    Shan, K
    Nagueh, SF
    Reardon, MJ
    Espada, R
    Letsou, GV
    Quinones, MA
    Zoghbi, WA
    CIRCULATION, 2000, 102 (18) : 748 - 748
  • [7] Resting Myocardial Contrast Echocardiography for the Evaluation of Coronary Microcirculation Dysfunction in Patients With Early Coronary Artery Disease
    Li, Xin
    He, Sheng
    Zhang, Yun-Shan
    Chen, Yu
    He, Jiang-Chun
    CLINICAL CARDIOLOGY, 2016, 39 (08) : 453 - 458
  • [8] MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY HAS THE POTENTIAL FOR THE ASSESSMENT OF CORONARY MICROVASCULAR RESERVE
    KAUL, S
    JAYAWEERA, AR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (02) : 356 - 358
  • [9] ATP Stress Myocardial Contrast Echocardiography Assessment of Coronary Microvascular Disease with Spasmodic Characteristics: A Case Report
    Liu, Xuebing
    Li, Chunmei
    CARDIOLOGY DISCOVERY, 2023, 3 (03): : 221 - 225
  • [10] Myocardial perfusion by contrast echocardiography: diagnosis of coronary artery disease using contrast-enhanced stress echocardiography and assessment of coronary anatomy and flow reserve
    Mulvagh, SL
    CORONARY ARTERY DISEASE, 2000, 11 (03) : 243 - 251