Two-dimensional and Three-dimensional Image-guided Evaluation of Patient Positioning for Intensity-modulated Radiation Therapy of Head and Neck Cancer

被引:1
作者
Johari, Zul Iskandar [1 ,2 ]
Azmi, Nor Aniza [1 ]
Ab Muin, Nur Fa'izah [3 ]
Latiff, Rukiah A. [1 ]
Fadzil, Muhammad Safwan Ahmad [1 ]
Razali, Rosmizan Ahmad [3 ]
机构
[1] Univ Kebangsaan Malaysia, Ctr Diagnost Therapeut & Invest Studies CODTIS, Fac Hlth Sci, Kuala Lumpur 50300, Wilayah Perseku, Malaysia
[2] Minist Hlth Malaysia, Med Radiat Surveillance Div, Putrajaya 62590, Wilayah Perseku, Malaysia
[3] Hosp Canselor Tuanku Muhriz, Radiotherapy & Oncol Dept, Cheras 56000, Wilayah Perseku, Malaysia
来源
MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES | 2023年 / 19卷 / 05期
关键词
Cone-beam computed tomography; Set-up error; Image-guided patient positioning; Head and Neck Cancer; intensity-modulated radiation therapy; RESIDUAL SETUP ERRORS; MARGINS; RADIOTHERAPY;
D O I
10.11113/mjfas.v19n5.3040
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Patient positioning accuracy is critical in radiation therapy, especially in intensity-modulated radiation therapy (IMRT) for head and neck cancer (HNC), as it can affect treatment effectiveness and safety. This retrospective study aimed to evaluate the accuracy of patient positioning techniques and compare the effectiveness of using multiple image-guided (IG) methods for IG-IMRT of HNC. Cone-beam computed tomography (CBCT) and kV-planar imaging (OBI) collected 3240 treatment couch coordinates in three translational directions from 60 HNC patients undergoing IMRT. Inter-fraction errors were assessed by registering the scans to the planning CT, and the population systematic set-up error (Sigma), random error (sigma), and planning target volume (PTV) margin were calculated. The results between OBI and CBCT were analyzed and compared using one-way ANOVA. The findings demonstrated that more than 80% of the image-guided patient positioning set-ups were acceptable. The mean couch displacement for image-guided techniques was negligible in all translational directions using OBI and CBCT. However, the PTV margin for both methods was more than 0.5 cm, except for the CBCTA-P direction. This study highlights the effectiveness of OBI and CBCT as modalities for evaluating and improving the accuracy of IMRT in HNC patients. Determination of the systematic and random errors and calculating the optimal PTV margin without rematching images can help improve the precision of patient positioning and ultimately lead to better treatment outcomes.
引用
收藏
页码:915 / 926
页数:12
相关论文
共 29 条
  • [1] Radiation therapy in head and neck cancer
    Alfouzan, Afnan F.
    [J]. SAUDI MEDICAL JOURNAL, 2021, 42 (03) : 247 - 254
  • [2] Anjanappa M, 2017, REP PRACT ONCOL RADI, V22, P396, DOI 10.1016/j.rpor.2017.07.005
  • [3] A Review of Modern Radiation Therapy Dose Escalation in Locally Advanced Head and Neck Cancer
    Atwell, D.
    Elks, J.
    Cahill, K.
    Hearn, N.
    Vignarajah, D.
    Lagopoulos, J.
    Min, M.
    [J]. CLINICAL ONCOLOGY, 2020, 32 (05) : 330 - 341
  • [4] Azizah A M., 2016, Malaysian national cancer registry report 2007-2011. Malaysia cancer statistics, data and figure
  • [5] Prospective observational study to estimate set-up errors and optimise PTV margins in patients undergoing IMRT for head and neck cancers from a Government cancer centre of Eastern India
    Biswas, Priyanka
    Lahiri, Debarshi
    Roy, Sanjoy
    Maji, Tapas
    Bhadra, Kallol
    Ray, Dilip Kumar
    Das, Subhadip
    De, Palas
    Mohanta, Bijan Kumar
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (01) : 52 - 58
  • [6] Current Therapeutic Strategies in Patients with Oropharyngeal Squamous Cell Carcinoma: Impact of the Tumor HPV Status
    Bozec, Alexandre
    Culie, Dorian
    Poissonnet, Gilles
    Demard, Francois
    Dassonville, Olivier
    [J]. CANCERS, 2021, 13 (21)
  • [7] Intensity-modulated radiation therapy: a review with a physics perspective
    Cho, Byungchul
    [J]. RADIATION ONCOLOGY JOURNAL, 2018, 36 (01): : 1 - 10
  • [8] Set-up errors in head and neck cancer treated with IMRT technique assessed by cone-beam computed tomography: a feasible protocol
    Delishaj, Durim
    Ursino, Stefano
    Pasqualetti, Francesco
    Matteucci, Fabrizio
    Cristaudo, Agostino
    Soatti, Carlo Pietro
    Barcellini, Amelia
    Paiar, Fabiola
    [J]. RADIATION ONCOLOGY JOURNAL, 2018, 36 (01): : 54 - 62
  • [9] Comparison of two thermoplastic immobilization mask systems in daily volumetric image guided radiation therapy for head and neck cancers
    Divneet, Mandair
    Ho Quoc-Anh
    Betsy, Wertheim
    Gia, Johnson
    Denise, Roe
    Christopher, Watchman
    Yi, Sun K.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (05):
  • [10] Assessment of residual setup errors for anatomical sub-structures in image-guided head-and-neck cancer radiotherapy
    Djordjevic, Milos
    Sjoholm, Emmelie
    Tullgren, Owe
    Sorcini, Bruno
    [J]. ACTA ONCOLOGICA, 2014, 53 (05) : 646 - 653