Two-dimensional and Three-dimensional Image-guided Evaluation of Patient Positioning for Intensity-modulated Radiation Therapy of Head and Neck Cancer

被引:1
作者
Johari, Zul Iskandar [1 ,2 ]
Azmi, Nor Aniza [1 ]
Ab Muin, Nur Fa'izah [3 ]
Latiff, Rukiah A. [1 ]
Fadzil, Muhammad Safwan Ahmad [1 ]
Razali, Rosmizan Ahmad [3 ]
机构
[1] Univ Kebangsaan Malaysia, Ctr Diagnost Therapeut & Invest Studies CODTIS, Fac Hlth Sci, Kuala Lumpur 50300, Wilayah Perseku, Malaysia
[2] Minist Hlth Malaysia, Med Radiat Surveillance Div, Putrajaya 62590, Wilayah Perseku, Malaysia
[3] Hosp Canselor Tuanku Muhriz, Radiotherapy & Oncol Dept, Cheras 56000, Wilayah Perseku, Malaysia
来源
MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES | 2023年 / 19卷 / 05期
关键词
Cone-beam computed tomography; Set-up error; Image-guided patient positioning; Head and Neck Cancer; intensity-modulated radiation therapy; RESIDUAL SETUP ERRORS; MARGINS; RADIOTHERAPY;
D O I
10.11113/mjfas.v19n5.3040
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Patient positioning accuracy is critical in radiation therapy, especially in intensity-modulated radiation therapy (IMRT) for head and neck cancer (HNC), as it can affect treatment effectiveness and safety. This retrospective study aimed to evaluate the accuracy of patient positioning techniques and compare the effectiveness of using multiple image-guided (IG) methods for IG-IMRT of HNC. Cone-beam computed tomography (CBCT) and kV-planar imaging (OBI) collected 3240 treatment couch coordinates in three translational directions from 60 HNC patients undergoing IMRT. Inter-fraction errors were assessed by registering the scans to the planning CT, and the population systematic set-up error (Sigma), random error (sigma), and planning target volume (PTV) margin were calculated. The results between OBI and CBCT were analyzed and compared using one-way ANOVA. The findings demonstrated that more than 80% of the image-guided patient positioning set-ups were acceptable. The mean couch displacement for image-guided techniques was negligible in all translational directions using OBI and CBCT. However, the PTV margin for both methods was more than 0.5 cm, except for the CBCTA-P direction. This study highlights the effectiveness of OBI and CBCT as modalities for evaluating and improving the accuracy of IMRT in HNC patients. Determination of the systematic and random errors and calculating the optimal PTV margin without rematching images can help improve the precision of patient positioning and ultimately lead to better treatment outcomes.
引用
收藏
页码:915 / 926
页数:12
相关论文
共 29 条
[1]   Radiation therapy in head and neck cancer [J].
Alfouzan, Afnan F. .
SAUDI MEDICAL JOURNAL, 2021, 42 (03) :247-254
[2]  
Anjanappa M, 2017, REP PRACT ONCOL RADI, V22, P396, DOI 10.1016/j.rpor.2017.07.005
[3]   A Review of Modern Radiation Therapy Dose Escalation in Locally Advanced Head and Neck Cancer [J].
Atwell, D. ;
Elks, J. ;
Cahill, K. ;
Hearn, N. ;
Vignarajah, D. ;
Lagopoulos, J. ;
Min, M. .
CLINICAL ONCOLOGY, 2020, 32 (05) :330-341
[4]  
Azizah A M., 2016, Malaysian national cancer registry report 2007-2011. Malaysia cancer statistics, data and figure
[5]  
Biswas P, 2020, J RADIOTHER PRACT, V19, P52, DOI 10.1017/S1460396919000487
[6]   Current Therapeutic Strategies in Patients with Oropharyngeal Squamous Cell Carcinoma: Impact of the Tumor HPV Status [J].
Bozec, Alexandre ;
Culie, Dorian ;
Poissonnet, Gilles ;
Demard, Francois ;
Dassonville, Olivier .
CANCERS, 2021, 13 (21)
[7]   Intensity-modulated radiation therapy: a review with a physics perspective [J].
Cho, Byungchul .
RADIATION ONCOLOGY JOURNAL, 2018, 36 (01) :1-10
[8]   Set-up errors in head and neck cancer treated with IMRT technique assessed by cone-beam computed tomography: a feasible protocol [J].
Delishaj, Durim ;
Ursino, Stefano ;
Pasqualetti, Francesco ;
Matteucci, Fabrizio ;
Cristaudo, Agostino ;
Soatti, Carlo Pietro ;
Barcellini, Amelia ;
Paiar, Fabiola .
RADIATION ONCOLOGY JOURNAL, 2018, 36 (01) :54-62
[9]   Comparison of two thermoplastic immobilization mask systems in daily volumetric image guided radiation therapy for head and neck cancers [J].
Divneet, Mandair ;
Ho Quoc-Anh ;
Betsy, Wertheim ;
Gia, Johnson ;
Denise, Roe ;
Christopher, Watchman ;
Yi, Sun K. .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (05)
[10]   Assessment of residual setup errors for anatomical sub-structures in image-guided head-and-neck cancer radiotherapy [J].
Djordjevic, Milos ;
Sjoholm, Emmelie ;
Tullgren, Owe ;
Sorcini, Bruno .
ACTA ONCOLOGICA, 2014, 53 (05) :646-653