Does False Lumen Thrombosis Lead to Better Outcomes in Patients with Aortic Dissection: A Meta-Analysis and Systematic Review

被引:1
作者
Zhang, Shiming [1 ]
Sun, Wei [1 ]
Liu, Shidong [1 ]
Song, Bing [1 ]
Xie, Lili [2 ]
Liu, Ruisheng [1 ]
机构
[1] Lanzhou Univ, Hosp 1, Dept Cardiovasc Surg, Lanzhou 730000, Gansu, Peoples R China
[2] Lanzhou Univ, Hosp 1, Dept Anesthesiol, Lanzhou 730000, Gansu, Peoples R China
关键词
aortic dissection; prognosis; false lumen; meta-analysis; INTRALUMINAL THROMBUS; DISTAL AORTA; ANEURYSM; REGISTRY; SURGERY; REPAIR;
D O I
10.59958/hsf.5739
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: For a long time, the association of the false lumen status and the outcomes of patients suffering from aortic dissection has been unclear, so this review article aims to study whether the unobstructed of the false lumen is related to the outcome of patients suffering from aortic dissection. Methods: We performed this systematic review and meta-analysis according to the Preferred Reporting Items for Systematic Reviews and Meta Analyzes Protocols (PRISMA) statement 2009 and registered with PROSPERO (CRD42022381869). We searched PubMed, the Cochrane library, Web of Science and Embase to collect potential studies. The Newcastle-Ottawa Scale was used to assess the quality of the included studies. The main outcome is long-term survival. Data included in the study were summarized using the risk ratio or mean difference and 95% confidence interval. Results: There were 16 trials, 2829 patients in total, with a mean age of 62.1 years. Compared with completely thrombosed false lumen, patent group has better long-term survival (risk ratio (RR), 0.88; 95% CI, 0.79 to 0.97; p = 0.01; I2 = 58%) and smaller yearly aortic growth rate (mean difference (MD), 1.03; 95% CI, 0.23 to 1.82; p = 0.01; I2 = 98%). In addition, patients with a patent false lumen had a lower risk of aortic event (RR, 0.81; 95% CI, 0.68 to 0.97; p = 0.02; I2 = 37%), but higher risk of aortic rupture (RR, 7.02; 95% CI, 2.55 to 19.3; p = 0.0002; I2 = 0) and hospital death (RR, 2.72; 95% CI, 1.45 to 5.08; p = 0.002; I2 = 0). Conclusion: Completely thrombosed of the false lumen is more beneficial to the long-term survival of patients with aortic dissection. And the risk of aortic rupture and hospital death in patients with patent false lumen is 7 times and 3 times that of patients with complete thrombosed false lumen. It is expected to provide individualized medical care for different types of patients according to different false lumen status to minimize death and related complications.
引用
收藏
页码:E628 / E638
页数:11
相关论文
共 50 条
  • [21] Early and mid-term mortality and morbidity of contemporary international endovascular treatment for type B aortic dissection - A systematic review and meta-analysis
    Li, Hai-Lei
    Wu, Shanshan
    Chan, Yiu Che
    Cheng, Stephen W.
    Guo, Wei
    Xiong, Jiang
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 301 : 56 - 61
  • [22] Risk factors for early death after surgery in patients with acute Stanford type A aortic dissection: A systematic review and meta-analysis
    Zhang, Yi
    Yang, Yuanyuan
    Guo, Jinhua
    Zhang, Xiaotian
    Cheng, Yunqing
    Sun, Tucheng
    Lin, Lixia
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 377 : 33 - 41
  • [23] Fluoroquinolones Are Associated With Increased Risk of Aortic Aneurysm or Dissection: Systematic Review and Meta-analysis
    Ribeiro, Nuno Vouga
    Melo, Ryan Gouveia
    Guerra, Nuno C.
    Nobre, Angelo
    Fernandes, Ricardo M.
    Pedro, Luis M.
    Costa, Joao
    Pinto, Fausto J.
    Caldeira, Daniel
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2021, 33 (04) : 907 - 918
  • [24] Extracorporeal life support after surgical repair for acute type a aortic dissection: A systematic review and meta-analysis
    Sa, Michel Pompeu
    Jacquemyn, Xander
    Hess, Nicholas
    Brown, James A.
    Caldonazo, Tulio
    Kirov, Hristo
    Doenst, Torsten
    Serna-Gallegos, Derek
    Kaczorowski, David
    Sultan, Ibrahim
    PERFUSION-UK, 2024, : 631 - 639
  • [25] Does pre-operative urodynamics lead to better outcomes in management of urinary incontinence in women? A linked systematic review and meta-analysis
    Lor, Kar Yee
    Soupashi, Maria
    Abdel-Fattah, Mohamed
    Mostafa, Alyaa
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2020, 244 : 141 - 153
  • [26] A systematic review and meta-analysis of retrograde type A aortic dissection after thoracic endovascular aortic repair in patients with type B aortic dissection
    Ali-Hasan-Al-Saegh, Sadeq
    Halloum, Nancy
    Scali, Salvatore
    Kriege, Marc
    Abualia, Mohannad
    Stamenovic, Davor
    Izzat, Mohammad Bashar
    Bohan, Patrick
    Kloeckner, Roman
    Oezkur, Mehmet
    Dorweiler, Bernhard
    Treede, Hendrik
    El Beyrouti, Hazem
    MEDICINE, 2023, 102 (15) : E32944
  • [27] Predictors of adverse events in uncomplicated type B aortic dissection: a systematic review with meta-analysis
    Romeiro, Ana B.
    Nogueira, Clara
    Coelho, Andreia
    Mansilha, Armando
    INTERNATIONAL ANGIOLOGY, 2021, 40 (05) : 416 - 424
  • [28] Systematic Review and Meta-analysis of Current Literature on Isolated Abdominal Aortic Dissection
    Liu, Yang
    Han, Maonan
    Zhao, Jichun
    Kang, Limei
    Ma, Yukui
    Huang, Bin
    Yuan, Ding
    Yang, Yi
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 59 (04) : 545 - 556
  • [29] Outcomes of hemi- vs. total arch replacement in acute type A aortic dissection: A systematic review and meta-analysis
    Ma, Likang
    Chai, Tianci
    Yang, Xiaojie
    Zhuang, Xinghui
    Wu, Qingsong
    Chen, Liangwan
    Qiu, Zhihuang
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [30] Do fluoroquinolones increase aortic aneurysm or dissection incidence and mortality? A systematic review and meta-analysis
    Chen, Can
    Patterson, Benjamin
    Simpson, Ruan
    Li, Yanli
    Chen, Zhangzhang
    Lv, Qianzhou
    Guo, Daqiao
    Li, Xiaoyu
    Fu, Weiguo
    Guo, Baolei
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9