IMU positioning affects range of motion measurement during squat motion analysis

被引:4
作者
Blandeau, Mathias [1 ]
Guichard, Romain [1 ]
Hubaut, Remy [1 ]
Leteneur, Sebastien [1 ]
机构
[1] Univ Polytech Hauts de France, CNRS, UMR LAMIH 8201, F-59313 Valenciennes, France
关键词
Inertial measurement units; Squat; Positioning; ADJUSTMENTS; VALIDATION; MOVEMENTS;
D O I
10.1016/j.jbiomech.2023.111598
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Inertial Measurement Units (IMUs) provides embedded and accessible (financially and technically speaking) motion analysis for sports or clinical applications (rehabilitation, therapy...). Despite being advertised for it ease of use, the very nature of IMU sensor makes it prone to errors which are usually corrected through calibration processes thus adding extra complexity for the users. The main goal of this study is to estimate the effect of sensor positioning on the thigh for a simple assessment of squat motion range of motion (ROM) as could be done in a pragmatic clinical approach (i.e., without prior calibration). Kinematics, squat counts and timing of three IMU sensors along the thigh were recorded during squat motion and compared to an optoelectronic reference system. Results showed concordance coefficients of the IMU system over 0.944 without the need for calibration with a preference for placement on the distal part of the segment regarding kinematics data.
引用
收藏
页数:5
相关论文
共 28 条
[11]  
Dumas R, 2012, Comput Methods Biomech Biomed Engin, V15 Suppl 1, P183
[12]  
Guichard R., 2021, COMPUT METHOD BIOMEC, V24, P3, DOI [10.1080/10255842.2021.1978758, DOI 10.1080/10255842.2021.1978758]
[13]   The importance of inertial measurement unit placement in assessing upper limb motion [J].
Hoglund, Gustav ;
Grip, Helena ;
Ohberg, Fredrik .
MEDICAL ENGINEERING & PHYSICS, 2021, 92 :1-9
[14]   Validation of magneto-inertial measuring units for measuring hip joint angles [J].
Horenstein, Rachel E. ;
Lewis, Cara L. ;
Yan, Sherry ;
Halverstadt, Anne ;
Shefelbine, Sandra J. .
JOURNAL OF BIOMECHANICS, 2019, 91 :170-174
[15]   Validation of an Embedded Motion-Capture and EMG Setup for the Analysis of Musculoskeletal Disorder Risks during Manhole Cover Handling [J].
Hubaut, Remy ;
Guichard, Romain ;
Greenfield, Julia ;
Blandeau, Mathias .
SENSORS, 2022, 22 (02)
[16]   Validity and reliability of wearable inertial sensors in healthy adult walking: a systematic review and meta-analysis [J].
Kobsar, Dylan ;
Charlton, Jesse M. ;
Tse, Calvin T. F. ;
Esculier, Jean-Francois ;
Graffos, Angelo ;
Krowchuk, Natasha M. ;
Thatcher, Daniel ;
Hunt, Michael A. .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2020, 17 (01)
[17]   A CONCORDANCE CORRELATION-COEFFICIENT TO EVALUATE REPRODUCIBILITY [J].
LIN, LI .
BIOMETRICS, 1989, 45 (01) :255-268
[18]   Designing acceptable emerging technologies: what contribution from ergonomics? [J].
Loup-Escande, E. ;
Loup, G. .
THEORETICAL ISSUES IN ERGONOMICS SCIENCE, 2021, 22 (05) :581-602
[19]   Wearable Inertial Sensor Systems for Lower Limb Exercise Detection and Evaluation: A Systematic Review [J].
O'Reilly, Martin ;
Caulfield, Brian ;
Ward, Tomas ;
Johnston, William ;
Doherty, Cailbhe .
SPORTS MEDICINE, 2018, 48 (05) :1221-1246
[20]   Experimental evaluation of accuracy and repeatability of a novel body-to-sensor calibration procedure for inertial sensor-based gait analysis [J].
Palermo, Eduardo ;
Rossi, Stefano ;
Marini, Francesca ;
Patane, Fabrizio ;
Cappa, Paolo .
MEASUREMENT, 2014, 52 :145-155