Magnetic Field Analysis and Measurement of Pulsed Septum Magnet

被引:0
作者
Tong, Jin [1 ]
Liu, Yongfang [1 ]
机构
[1] Chinese Acad Sci, Shanghai Adv Res Inst, Shanghai 201204, Peoples R China
来源
APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL | 2023年 / 38卷 / 09期
基金
中国国家自然科学基金;
关键词
Diffraction limited storage ring (DLSR); eddy current; injection and extraction; magnetic field simulation; septum thermal;
D O I
10.13052/2023.ACES.J.380917
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional off -axis injection becomes inadequate in diffraction limited storage ring (DLSR) for its small dynamic aperture (DA). On -axis injection with thin septum could solve the problem. This paper focuses on the theoretical calculation, field simulation, and measurement of thin septum magnets. The scheme of eddycurrent type thin septum magnets (the thinnest portion is with the thickness of 0.9 mm) was adopted with laminated silicon steel sheets as the magnet core. The simulation of main field, stray field along the beam trajectory, the leakage field decayed over 1 millisecond time was carried out within Opera 2D/3D. Field measurement and analysis of thin septum magnets also has been conducted comprehensively. The results meet requirements, and the work laid a foundation for injection technology of an advanced light source.
引用
收藏
页码:751 / 755
页数:5
相关论文
共 7 条
  • [1] Infrared Temperature Measurements of the Blade Tip for a Turbine Operating at Corrected Engine Conditions
    Christensen, Louis
    Celestina, Richard
    Sperling, Spencer
    Mathison, Randall
    Aksoy, Hakan
    Liu, Jong
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2021, 143 (10):
  • [2] Kang W, 2001, HIGH ENERG PHYS NUC, V25, P264
  • [3] Kirilenko AA, 2006, APPL COMPUT ELECTROM, V21, P155
  • [4] Design and Measurement of the Septum Magnet for the Taiwan Photon Source
    Kuo, C. Y.
    Yang, C. S.
    Lin, F. Y.
    Chu, Y. L.
    Jan, J. C.
    Huang, J. C.
    Hwang, C. S.
    Chen, J. R.
    Liu, Y. H.
    Chang, C. H.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (03)
  • [5] Eddy current septum magnets for injection and extraction at SSRF
    Ouyang Lian-Hua
    Gu Ming
    Liu Bo
    Chen Rong
    [J]. CHINESE PHYSICS C, 2010, 34 (03) : 389 - 393
  • [6] Swenson C., 2016, P IPAC2016, P1161
  • [7] Numerical analysis of magnetic field measurement based on Faraday rotation in a no-core tellurite fiber
    Zhang, Fan
    Yan, Xin
    Zhang, Xuenan
    Wang, Fang
    Li, Shuguang
    Suzuki, Takenobu
    Ohishi, Yasutake
    Cheng, Tonglei
    [J]. OPTICAL FIBER TECHNOLOGY, 2021, 63 (63)