Mechanical performance of a bond-type anchorage system for CFRP cable exposed to elevated temperature

被引:8
作者
Jiang, Zhengwen [1 ,2 ]
Pi, Xiangfei [2 ]
Fang, Zhi [1 ,2 ]
Li, Zerun [2 ]
Li, Quanhao [2 ]
Wang, Zhiwei [3 ]
机构
[1] Hunan Univ, Coll Civil Engn, Key Lab Damage Diag Engn Struct Hunan Prov, Changsha 410082, Peoples R China
[2] Hunan Univ, Coll Civil Engn, Key Lab Wind & Bridge Engn Hunan Prov, Changsha 410082, Peoples R China
[3] Zhongfu Carbon Fiber Core Cable Technol Co Ltd, Lianyungang 222069, Jiangsu, Peoples R China
关键词
Carbon fiber reinforced polymer (CFRP) cable; Bond -type anchorage system; Ultra -high performance concrete (UHPC); High -temperature pullout test; Bond strength; Slippage; BEHAVIOR; DESIGN; FIRE;
D O I
10.1016/j.engstruct.2023.117388
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Both high-temperature pullout tests without and with pre-tension load were conducted on the bond-type anchorage system specimens with bonding medium of UHPC (Ultra-high Performance Concrete) for Carbon fiber reinforced polymer (CFRP) cable in order to fully understand the bonding behavior of CFRP cable-UHPC interface under high temperature. The variation laws of ultimate pullout load, average bond strength of CFRP cable-UHPC interface and slippage corresponding to ultimate pullout load were uncovered in two types of high -temperature pullout tests. Then, the bond performances of CFRP cable-UHPC interface in high-temperature pullout tests with pre-tension load ratio from 0.2 to 0.6 and target temperature in the range of 100-210 degrees C were compared to these in high-temperature pullout tests without pre-tension load in order to identify the effect of temperature-load path. Finally, theoretical models for determining average bond strength of CFRP cable-UHPC interface and critical bond length of CFRP cable for the bond-type anchorage system under high temperature were developed by incorporating effects of high temperature and pre-tension load ratio. The obtained results demonstrate that the dominant failure mode of the bond-type anchorage system in high-temperature pullout tests is slip failure of CFRP cable-UHPC interface, and shear failure morphologies of embossed rid for CFRP tendon are closely correlated with target temperature. In high-temperature pullout tests without pre-tension load, the average bond strength of CFRP tendon-UHPC interface gradually decreased as the increasing target temperature, the corresponding attenuation ratios in temperature ranges of 25-300 degrees C and 300-400 degrees C are 84% and 47%, respectively. In high-temperature pullout tests with pre-tension load, the average bond strength of CFRP tendon-UHPC interface approximately linearly decreased as the increasing target temperature or pre-tension load ratio. The presence of pre-tension load results in acceleration of damage of CFRP cable-UHPC interface, and the damage degree is proportional to pre-tension load. The developed theoretical models of mechanical properties for the bond-type anchorage system exposed to high temperature can accurately predict average bond strength of CFRP cable-UHPC interface and critical bond length of CFRP cable.
引用
收藏
页数:16
相关论文
共 44 条
[1]   Novel self-anchored CFRP cable system: Concept and anchorage behavior [J].
Ai, Pengcheng ;
Feng, Peng ;
Lin, Hongwei ;
Zhu, Pengcheng ;
Ding, Guozhen .
COMPOSITE STRUCTURES, 2021, 263
[2]   Styrene-butadiene rubber modified cementitious grouts for embedding anchors in humid environments [J].
Assaad, Joseph J. ;
Gerges, Najib .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2019, 84 :317-325
[3]   Tensile properties and pullout behaviour of AFRP and CFRP rods for grouted anchor applications [J].
Benmokrane, B ;
Zhang, BR ;
Chennouf, A .
CONSTRUCTION AND BUILDING MATERIALS, 2000, 14 (03) :157-170
[4]   Influence of high temperatures on the bond between carbon Fibre-Reinforced polymer bars and concrete [J].
Cos-Gayon Lopez, Fernando ;
Benlloch Marco, Javier ;
Calvet Rodriguez, Victor .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 309
[5]   A novel variable curvature clamping anchor for the multilayer CFRP plate cable: Concept, numerical investigation, and design proposals [J].
Duo, Yongyu ;
Liu, Xiaogang ;
Yue, Qingrui ;
Chen, Hongbing .
STRUCTURES, 2022, 43 :164-177
[6]   Experimental investigation of a bond-type anchorage system for multiple FRP tendons [J].
Fang, Zhi ;
Zhang, Kuangyi ;
Tu, Bing .
ENGINEERING STRUCTURES, 2013, 57 :364-373
[7]   Performance of anchorage assemblies for CFRP cables under fatigue loads [J].
Feng, Bo ;
Wang, Xin ;
Wu, Zhishen ;
Yang, Yaqiang ;
Pan, Zhihong .
STRUCTURES, 2021, 29 :947-953
[8]   Static and Fatigue Behavior of Multitendon CFRP Cables with Integrated Anchorages [J].
Feng, Bo ;
Wang, Xin ;
Wu, Zhishen .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2019, 23 (06)
[9]   Fire behaviour of FRP-strengthened reinforced concrete structural elements: A state-of-the-art review [J].
Firmo, Joao P. ;
Correia, Joao R. ;
Bisby, Luke A. .
COMPOSITES PART B-ENGINEERING, 2015, 80 :198-216
[10]  
Guide ACI, 2015, for the design and construction of structural concrete reinforced with Fiber-reinforced Polymer (FRP) bars: ACI 440.1R-15, P150