共 54 条
An electrochemical aptasensor based on AuPt@PEI-g-C3N4 combined with a rolling circle amplification strategy for ultrasensitive detection of ciprofloxacin
被引:3
作者:
Wang, Qianqian
[1
]
He, Baoshan
[1
]
Liu, Yao
[2
]
Wang, Yuling
[3
,4
]
Jiang, Liying
[5
]
Jin, Huali
[1
]
Wei, Min
[1
]
Ren, Wenjie
[1
]
Suo, Zhiguang
[1
]
Xu, Yiwei
[1
]
机构:
[1] Henan Univ Technol, Sch Food Sci & Technol, Zhengzhou 450001, Henan, Peoples R China
[2] Henan Sci Res Platform Serv Ctr, Zhengzhou 450003, Henan, Peoples R China
[3] Macquarie Univ, Fac Sci & Engn, ARC Ctr Excellence Nanoscale BioPhoton CNBP, Sydney, NSW 2109, Australia
[4] Macquarie Univ, Fac Sci & Engn, Sch Nat Sci, Sydney, NSW 2109, Australia
[5] Zhengzhou Univ Light Ind, Coll Elect & Informat Engn, Zhengzhou 450002, Henan, Peoples R China
基金:
中国国家自然科学基金;
关键词:
ciprofloxacin;
Apamer;
Nanomaterials;
Electrochemical detection;
Sensor;
REDUCED GRAPHENE OXIDE;
METHYLENE-BLUE;
SPECTROPHOTOMETRIC DETERMINATION;
ELECTROCATALYTIC ACTIVITY;
G-QUADRUPLEX;
ENROFLOXACIN;
BINDING;
NANOCOMPOSITE;
NANOPARTICLES;
REDUCTION;
D O I:
10.1016/j.microc.2023.109871
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
The precise and sensitive quantification of ciprofloxacin (CIP) is imperative due to its prevalent misapplication and overutilization, which can elicit detrimental side effects. Here, an electrochemical aptasensor based on PEI-g-C3N4 compounded with gold-platinum nanoshell nanomaterials (AuPt@PEI-g-C3N4) combined with a rolling circle amplification (RCA) strategy for an ultrasensitive detection of CIP. Physicochemical properties of nanoparticles and aptamers and analytical parameters of aptasensor were determined by Fourier Transform Infrared, scanning and transmission electron microscopy, gel electrophoresis, cyclic voltammetry, and electrochemical impedance spectroscopy. Furthermore, the RCA strategy was employed to generate long G-rich sequences to load an amount of methylene blue (MB) as signal probes in a potassium ions (K+) environment for signal amplification. In the presence of CIP, the formation of the Apt-CIP complex will cause the dissociation of signal probes from gold electrodes (AuE), reducing electrochemical signals significantly. Under optimal experimental conditions, the designed aptasensor showed excellent comprehensive performance with a good linear relationship in the wide range of 1.0 x 10(-4) to 1.0 x 10(2) ng/mL, and its detection limit was low at 1.03 x 10(-5) ng/mL. The assay revealed satisfactory levels of specificity, immunity to interference, stability, and repeatability. Additionally, we successfully applied this aptasensor to spiked milk and surface water samples from Dongfeng Canal (China) for CIP detection.
引用
收藏
页数:9
相关论文