Cuffless Beat-to-Beat Blood Pressure Estimation from Photoplethysmogram Signals

被引:0
作者
Wuerich, Carolin [1 ]
Wiede, Christian [1 ]
Schiele, Gregor [2 ]
机构
[1] Fraunhofer IMS, Duisburg, Germany
[2] Univ Duisburg Essen, Embedded Syst, Duisburg, Germany
来源
2023 IEEE 36TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, CBMS | 2023年
关键词
cuffless blood pressure; photoplethysmogram; personalized models; beat-to-beat predictions; signal processing; ResNet;
D O I
10.1109/CBMS58004.2023.00235
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In recent years, many studies have been published on blood pressure (BP) estimation from photoplethysmogram (PPG) signals to overcome limitations of current BP devices, such as high risk of complications in invasive methods or limited accuracy, temporal resolution and comfort for cuff-based systems. However, most of these studies suffer from methodological drawbacks regarding data handling, leading to overly positive evaluation of such methods. We present an approach on beat-to-beat blood pressure estimation from raw PPG signals that is evaluated extensively on data of unseen test subjects. The proposed method obtains an mean absolute error +/- standard deviation of 8.07 +/- 6.86 mmHg for DBP and 8.73 +/- 7.36 mmHg for SBP. To increase transparency of the model's decision-making, we examine layer activation of the employed convolutional neural network. Moreover, we analyze the impact of fine tuning for personalization of the model and derive strategies to enhance the personalization process.
引用
收藏
页码:305 / 310
页数:6
相关论文
共 50 条
  • [31] Cuffless Blood Pressure Estimation Using Dual Physiological Signal and Its Morphological Features
    Wang, Liang-Hung
    Sun, Kun-Kun
    Xie, Chao-Xin
    Fan, Ming-Hui
    Abu, Patricia Angela R.
    Huang, Pao-Cheng
    IEEE SENSORS JOURNAL, 2023, 23 (11) : 11956 - 11967
  • [32] Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography
    Toan Huu Huynh
    Jafari, Roozbeh
    Chung, Wan-Young
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (04) : 967 - 976
  • [33] Advancing cuffless arterial blood pressure estimation: A patient-specific optimized approach reducing computational requirements
    Gonzalez-Novoa, Jose A.
    Busto, Laura
    Campanioni, Silvia
    Martinez, Carlos
    Farina, Jose
    Rodriguez-Andina, Juan J.
    Juan-Salvadores, Pablo
    Jimenez, Victor
    Iniguez, Andres
    Veiga, Cesar
    FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2025, 166
  • [34] Accurate Blood Pressure Estimation During Activities of Daily Living: A Wearable Cuffless Solution
    Landry, Cederick
    Hedge, Eric T.
    Hughson, Richard L.
    Peterson, Sean D.
    Arami, Arash
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (07) : 2510 - 2520
  • [35] SleepBP-Net: A Time-Distributed Convolutional Network for Nocturnal Blood Pressure Estimation From Photoplethysmogram
    Khajehpiri, Boshra
    Granger, Eric
    de Zambotti, Massimiliano
    Baker, Fiona C.
    Yuksel, Dilara
    Forouzanfar, Mohamad
    IEEE SENSORS JOURNAL, 2024, 24 (12) : 19590 - 19600
  • [36] Cuff-less Calibration-free Blood Pressure Estimation under Ambulatory Environment using Pulse Wave Velocity and Photoplethysmogram Signals
    Sanuki, Haruyuki
    Rui Fukui
    Inajima, Tsukasa
    Warisawa, Shin'ichi
    PROCEEDINGS OF THE 10TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 4: BIOSIGNALS, 2017, : 42 - 48
  • [37] PPG2ABP: Translating Photoplethysmogram (PPG) Signals to Arterial Blood Pressure (ABP) Waveforms
    Ibtehaz, Nabil
    Mahmud, Sakib
    Chowdhury, Muhammad E. H.
    Khandakar, Amith
    Khan, Muhammad Salman
    Ayari, Mohamed Arselene
    Tahir, Anas M.
    Rahman, M. Sohel
    BIOENGINEERING-BASEL, 2022, 9 (11):
  • [38] A Shallow U-Net Architecture for Reliably Predicting Blood Pressure (BP) from Photoplethysmogram (PPG) and Electrocardiogram (ECG) Signals
    Mahmud, Sakib
    Ibtehaz, Nabil
    Khandakar, Amith
    Tahir, Anas M.
    Rahman, Tawsifur
    Islam, Khandaker Reajul
    Hossain, Md Shafayet
    Rahman, M. Sohel
    Musharavati, Farayi
    Ayari, Mohamed Arselene
    Islam, Mohammad Tariqul
    Chowdhury, Muhammad E. H.
    SENSORS, 2022, 22 (03)
  • [39] Inter-beat Interval Estimation from Extremely Noisy Single Lead Electrocardiograms
    Burguera, Antoni
    IFAC PAPERSONLINE, 2020, 53 (02): : 16482 - 16487
  • [40] A non-invasive continuous cuffless blood pressure estimation using dynamic Recurrent Neural Networks
    Senturk, Umit
    Polat, Kemal
    Yucedag, Ibrahim
    APPLIED ACOUSTICS, 2020, 170