Cuffless Beat-to-Beat Blood Pressure Estimation from Photoplethysmogram Signals

被引:0
|
作者
Wuerich, Carolin [1 ]
Wiede, Christian [1 ]
Schiele, Gregor [2 ]
机构
[1] Fraunhofer IMS, Duisburg, Germany
[2] Univ Duisburg Essen, Embedded Syst, Duisburg, Germany
关键词
cuffless blood pressure; photoplethysmogram; personalized models; beat-to-beat predictions; signal processing; ResNet;
D O I
10.1109/CBMS58004.2023.00235
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In recent years, many studies have been published on blood pressure (BP) estimation from photoplethysmogram (PPG) signals to overcome limitations of current BP devices, such as high risk of complications in invasive methods or limited accuracy, temporal resolution and comfort for cuff-based systems. However, most of these studies suffer from methodological drawbacks regarding data handling, leading to overly positive evaluation of such methods. We present an approach on beat-to-beat blood pressure estimation from raw PPG signals that is evaluated extensively on data of unseen test subjects. The proposed method obtains an mean absolute error +/- standard deviation of 8.07 +/- 6.86 mmHg for DBP and 8.73 +/- 7.36 mmHg for SBP. To increase transparency of the model's decision-making, we examine layer activation of the employed convolutional neural network. Moreover, we analyze the impact of fine tuning for personalization of the model and derive strategies to enhance the personalization process.
引用
收藏
页码:305 / 310
页数:6
相关论文
共 50 条
  • [21] An elastic manifold learning approach to beat-to-beat interval estimation with ballistocardiography signals
    Shen, Gang
    Ding, Ruidong
    Yang, Mingqi
    Han, Dan
    Zhang, Biyong
    ADVANCED ENGINEERING INFORMATICS, 2020, 44
  • [22] Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver
    David S. Goldstein
    William P. Cheshire
    Clinical Autonomic Research, 2017, 27 : 361 - 367
  • [23] Finger beat-to-beat blood pressure responses to successive hand elevations
    Raamat, R.
    Jagomagi, K.
    Talts, J.
    Mager, I.
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (05) : 522 - 527
  • [24] Beat-to-beat blood pressure biofeedback as a supplementary treatment for arterial hypertension
    Piesbergen, Christoph
    Kircher, Katharina
    Weber, Reinhard
    VERHALTENSTHERAPIE, 2008, 18 (02) : 83 - 90
  • [25] BEAT-TO-BEAT BLOOD-PRESSURE RESPONSE IN ASYMPTOMATIC IDDM SUBJECTS
    GOLDSTEIN, IB
    NALIBOFF, BD
    SHAPIRO, D
    FRANK, HJL
    DIABETES CARE, 1988, 11 (10) : 774 - 779
  • [26] Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver
    Goldstein, David S.
    Cheshire, William P., Jr.
    CLINICAL AUTONOMIC RESEARCH, 2017, 27 (06) : 361 - 367
  • [27] Beat-to-Beat Blood Pressure Variation and Cardiovascular Organ Injuries in Hypertension
    Ishimitsu, Toshihiko
    CIRCULATION JOURNAL, 2014, 78 (09) : 2162 - 2163
  • [28] Effect of peripheral vasoconstriction on the beat-to-beat measurement of finger blood pressure
    Raamat, R
    Talts, J
    Jagomägi, K
    Kingisepp, PH
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2223 - 2226
  • [29] Reduced resting beat-to-beat blood pressure variability in multiple sclerosis
    Trotter, Claire
    Young, Ben
    Huang, Mu
    Allen, Dustin
    Fade, Paul
    Davis, Scott
    FASEB JOURNAL, 2021, 35
  • [30] ADOPTION OF CONTINUOUS BEAT-TO-BEAT NOCTURNAL BLOOD PRESSURE MEASUREMENT IN AMBULATORY BLOOD PRESSURE MONITORING
    Estrada, Sebastian
    Kwon, Younghoon
    Baruch, Martin
    Harrison, Elizabeth
    Williams, Ronald
    Cho, Yeilim
    Gerdt, David
    Bonner, Heather
    Mazimba, Sula
    Berry, Richard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1893 - 1893