Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer

被引:4
|
作者
Wang, Yiran [1 ,2 ,3 ,5 ,6 ]
Wan, Ting [5 ,6 ]
Liu, Luze [5 ,6 ]
Xue, Yuyuan [1 ,2 ,3 ]
Chen, Xinyao [1 ,2 ,3 ]
Savini, Giacomo [7 ]
Schiano-Lomoriello, Domenico [7 ]
Zhou, Xingtao [1 ,2 ,3 ,4 ]
Yu, Jinjin [1 ,2 ,3 ,4 ]
Huang, Jinhai [1 ,2 ,3 ,4 ]
机构
[1] Fudan Univ, ENT Hosp, Eye Inst, Shanghai, Peoples R China
[2] Fudan Univ, Eye & ENT Hosp, Inst Med & Engn Innovat, Dept Ophthalmol, Shanghai, Peoples R China
[3] Chinese Acad Med Sci, Fudan Univ, NHC Key Lab Myopia, Key Lab Myopia, 19 Baoqing Rd, Shanghai 200031, Peoples R China
[4] Shanghai Res Ctr Ophthalmol & Optometry, Shanghai, Peoples R China
[5] Wenzhou Med Univ, Eye Hosp, Wenzhou, Zhejiang, Peoples R China
[6] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[7] GB Bietti Fdn IRCCS, Rome, Italy
基金
中国国家自然科学基金;
关键词
SW-9000; MS-39; Agreement; Ocular biometric parameters; Optical biometry; CHAMBER DEPTH MEASUREMENTS; ORBSCAN IIZ; PENTACAM; THICKNESS; KERATOCONUS; PARAMETERS; IOLMASTER; DIAMETER;
D O I
10.1186/s40662-023-00330-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo assess agreement of measurements between a new optical low coherence reflectometry (OLCR) biometer (SW-9000, Suoer, Tianjin, China) and a spectral-domain optical coherence tomographer (SD-OCT)/Placido topographer (MS-39, CSO, Florence, Italy) in healthy subjects.MethodsA total of 66 right eyes from 66 healthy subjects were enrolled in this prospective study. Three consecutive measurements were randomly obtained with both devices by the same experienced operator to assess agreement. Bland-Altman plots and 95% limits of agreement (LoA) were used to verify the agreement between the devices. Results are presented as mean +/- standard deviation (SD).ResultsThe SD-OCT/Placido tomographer showed high agreement with the OLCR biometer for all parameters included in this study. The mean differences of central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), mean keratometry (Km) and corneal diameter (CD) were 2.21 +/- 2.67 mu m (P < 0.001), - 0.10 +/- 0.03 mm (P < 0.001), - 0.10 +/- 0.04 mm (P < 0.001), - 0.01 +/- 0.22 D (P = 0.773) and 0.20 +/- 0.16 mm (P < 0.001), respectively. This implies that the inter-device difference in Km was not statistically significant, while the differences in CCT, ACD, AQD, CD were statistically but not clinically significant. The 95% LoAs of CCT, ACD, AQD, Km and CD were - 3.01 to 7.44 mu m, - 0.16 to - 0.05 mm, - 0.18 to - 0.03 mm, - 0.45 to 0.43 D, and - 0.12 to 0.51 mm, respectively.ConclusionsFor CCT, ACD, AQD, Km, and CD in healthy subjects, the new OLCR biometer has high agreement with the SD-OCT/Placido tomographer and can be used interchangeably due to the narrow range of 95% LoAs.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Repeatability and Agreement of Two Swept-Source Optical Coherence Tomographers for Anterior Segment Parameter Measurements
    Cheng, Shi-Ming
    Zhang, Jia-Sheng
    Li, Tian-tian
    Wu, Ze-tong
    Wang, Po
    Yu, A-Yong
    JOURNAL OF GLAUCOMA, 2022, 31 (07) : 602 - 608
  • [32] Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
    Bao Shu
    Fangjun Bao
    Giacomo Savini
    Weicong Lu
    Ruixue Tu
    Haisi Chen
    Benhao Song
    Qinmei Wang
    Jinhai Huang
    Eye and Vision, 7
  • [33] Clinical Applications of Anterior Segment Optical Coherence Tomography
    Lim, Su-Ho
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [34] When to use anterior segment optical coherence tomography
    Atalay, Eray
    Yu, Daryle Jason
    Nongpiur, Monisha Esther
    EXPERT REVIEW OF OPHTHALMOLOGY, 2020, 15 (04) : 233 - 248
  • [35] Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
    Srivannaboon, Sabong
    Chirapapaisan, Chareenun
    Chonpimai, Pratuangsri
    Loket, Siriwan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10) : 2224 - 2232
  • [36] Agreement in anterior segment measurements between swept-source optical coherence and dual Scheimpflug tomography devices in keratoconus eyes
    Lee, Yunjin
    Oh, Joo Youn
    Choi, Hyuk Jin
    Kim, Mee Kum
    Yoon, Chang Ho
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [37] Repeatability and agreement of a new anterior segment optical coherence tomography with standard devices in normal, keratoconus, and post-refractive eyes
    Kundu, Gairik
    Shetty, Naren
    Modak, Durgalaxmi
    Kaweri, Luci
    Khamar, Pooja
    Arora, Vishal
    Nuijts, Rudy M. M. A.
    Shetty, Rohit
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2025, 73 (03) : 325 - 334
  • [38] Comparison of a new anterior segment optical coherence tomography and Oculus Pentacam for measurement of anterior chamber depth and corneal thickness
    Li, Xuepei
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)
  • [39] Agreement between anterior segment parameters obtained by a new ultrasound biomicroscopy and a swept-source fourier-domain anterior segment optical coherence tomography.
    Li, Xiuyuan
    Chang, Pingjun
    Li, Zhangliang
    Qian, Shuyi
    Zhu, Zehui
    Wang, Qianwei
    Yun-E, Zhao
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (12) : 1333 - 1340
  • [40] Comparability of anterior chamber depth measurements with partial coherence interferometry and optical low-coherence reflectometry in pseudophakic eyes
    Luft, Nikolaus
    Hirnschall, Nino
    Farrokhi, Sanaz
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08) : 1678 - 1684