Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer

被引:4
|
作者
Wang, Yiran [1 ,2 ,3 ,5 ,6 ]
Wan, Ting [5 ,6 ]
Liu, Luze [5 ,6 ]
Xue, Yuyuan [1 ,2 ,3 ]
Chen, Xinyao [1 ,2 ,3 ]
Savini, Giacomo [7 ]
Schiano-Lomoriello, Domenico [7 ]
Zhou, Xingtao [1 ,2 ,3 ,4 ]
Yu, Jinjin [1 ,2 ,3 ,4 ]
Huang, Jinhai [1 ,2 ,3 ,4 ]
机构
[1] Fudan Univ, ENT Hosp, Eye Inst, Shanghai, Peoples R China
[2] Fudan Univ, Eye & ENT Hosp, Inst Med & Engn Innovat, Dept Ophthalmol, Shanghai, Peoples R China
[3] Chinese Acad Med Sci, Fudan Univ, NHC Key Lab Myopia, Key Lab Myopia, 19 Baoqing Rd, Shanghai 200031, Peoples R China
[4] Shanghai Res Ctr Ophthalmol & Optometry, Shanghai, Peoples R China
[5] Wenzhou Med Univ, Eye Hosp, Wenzhou, Zhejiang, Peoples R China
[6] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[7] GB Bietti Fdn IRCCS, Rome, Italy
基金
中国国家自然科学基金;
关键词
SW-9000; MS-39; Agreement; Ocular biometric parameters; Optical biometry; CHAMBER DEPTH MEASUREMENTS; ORBSCAN IIZ; PENTACAM; THICKNESS; KERATOCONUS; PARAMETERS; IOLMASTER; DIAMETER;
D O I
10.1186/s40662-023-00330-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo assess agreement of measurements between a new optical low coherence reflectometry (OLCR) biometer (SW-9000, Suoer, Tianjin, China) and a spectral-domain optical coherence tomographer (SD-OCT)/Placido topographer (MS-39, CSO, Florence, Italy) in healthy subjects.MethodsA total of 66 right eyes from 66 healthy subjects were enrolled in this prospective study. Three consecutive measurements were randomly obtained with both devices by the same experienced operator to assess agreement. Bland-Altman plots and 95% limits of agreement (LoA) were used to verify the agreement between the devices. Results are presented as mean +/- standard deviation (SD).ResultsThe SD-OCT/Placido tomographer showed high agreement with the OLCR biometer for all parameters included in this study. The mean differences of central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), mean keratometry (Km) and corneal diameter (CD) were 2.21 +/- 2.67 mu m (P < 0.001), - 0.10 +/- 0.03 mm (P < 0.001), - 0.10 +/- 0.04 mm (P < 0.001), - 0.01 +/- 0.22 D (P = 0.773) and 0.20 +/- 0.16 mm (P < 0.001), respectively. This implies that the inter-device difference in Km was not statistically significant, while the differences in CCT, ACD, AQD, CD were statistically but not clinically significant. The 95% LoAs of CCT, ACD, AQD, Km and CD were - 3.01 to 7.44 mu m, - 0.16 to - 0.05 mm, - 0.18 to - 0.03 mm, - 0.45 to 0.43 D, and - 0.12 to 0.51 mm, respectively.ConclusionsFor CCT, ACD, AQD, Km, and CD in healthy subjects, the new OLCR biometer has high agreement with the SD-OCT/Placido tomographer and can be used interchangeably due to the narrow range of 95% LoAs.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
    Shu, Bao
    Bao, Fangjun
    Savini, Giacomo
    Lu, Weicong
    Tu, Ruixue
    Chen, Haisi
    Song, Benhao
    Wang, Qinmei
    Huang, Jinhai
    EYE AND VISION, 2020, 7 (01)
  • [22] Effects of Valsalva Maneuver on Ocular Biometric Parameters: Optical Low-Coherence Reflectometry Biometer Study
    Mete, Alper
    Kimyon, Sabit
    Uzun, Irfan
    Kara, Necip
    SEMINARS IN OPHTHALMOLOGY, 2016, 31 (06) : 515 - 518
  • [23] Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry
    Gao, Rongrong
    Chen, Hao
    Savini, Giacomo
    Miao, Yaxin
    Wang, Xiaorui
    Yang, Jing
    Zhao, Weiqi
    Wang, Qinmei
    Huang, Jinhai
    SCIENTIFIC REPORTS, 2017, 7
  • [24] Changes in the anterior segment after cycloplegia with a biometer using swept-source optical coherence tomography
    Higashiyama, Tomoaki
    Iwasa, Maki
    Ohji, Masahito
    PLOS ONE, 2017, 12 (08):
  • [25] Comparison of a new biometer using swept-source optical coherence tomography and a conventional biometer using partial coherence interferometry
    Higashiyama, Tomoaki
    Mori, Hazuki
    Nakajima, Fumi
    Ohji, Masahito
    PLOS ONE, 2018, 13 (04):
  • [26] Comparison of Anterior Segment Measurements Between Swept-source Optical Coherence Tomography and Schiempflug Coherence Interferometer
    Song, Jiyun
    Na, Kyung Sun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (12): : 1158 - 1167
  • [27] Comparison of a new optical biometry with an optical low-coherence reflectometry for ocular biometry
    Guler, Emre
    Kulak, Ali Ender
    Totan, Yuksel
    Yuvarlak, Armagan
    Hepsen, Ibrahim Feyzi
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (05) : 336 - 341
  • [28] Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mohammed
    PLOS ONE, 2021, 16 (05):
  • [29] Repeatability of 2 swept-source OCT biometers and 1 optical low-coherence reflectometry biometer
    Fisus, Andreea D.
    Hirnschall, Nino D.
    Ruiss, Manuel
    Pilwachs, Caroline
    Georgiev, Stefan
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (10) : 1302 - 1307
  • [30] Lower Tear Meniscus Measurements Using a New Anterior Segment Swept-Source Optical Coherence Tomography and Agreement With Fourier-Domain Optical Coherence Tomography
    Arriola-Villalobos, Pedro
    Ignacio Fernandez-Vigo, Jose
    Diaz-Valle, David
    Almendral-Gomez, Jaime
    Fernandez-Perez, Cristina
    Benitez-del-Castillo, Jose M.
    CORNEA, 2017, 36 (02) : 183 - 188