Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer

被引:4
|
作者
Wang, Yiran [1 ,2 ,3 ,5 ,6 ]
Wan, Ting [5 ,6 ]
Liu, Luze [5 ,6 ]
Xue, Yuyuan [1 ,2 ,3 ]
Chen, Xinyao [1 ,2 ,3 ]
Savini, Giacomo [7 ]
Schiano-Lomoriello, Domenico [7 ]
Zhou, Xingtao [1 ,2 ,3 ,4 ]
Yu, Jinjin [1 ,2 ,3 ,4 ]
Huang, Jinhai [1 ,2 ,3 ,4 ]
机构
[1] Fudan Univ, ENT Hosp, Eye Inst, Shanghai, Peoples R China
[2] Fudan Univ, Eye & ENT Hosp, Inst Med & Engn Innovat, Dept Ophthalmol, Shanghai, Peoples R China
[3] Chinese Acad Med Sci, Fudan Univ, NHC Key Lab Myopia, Key Lab Myopia, 19 Baoqing Rd, Shanghai 200031, Peoples R China
[4] Shanghai Res Ctr Ophthalmol & Optometry, Shanghai, Peoples R China
[5] Wenzhou Med Univ, Eye Hosp, Wenzhou, Zhejiang, Peoples R China
[6] Wenzhou Med Univ, Sch Ophthalmol & Optometry, Wenzhou, Zhejiang, Peoples R China
[7] GB Bietti Fdn IRCCS, Rome, Italy
基金
中国国家自然科学基金;
关键词
SW-9000; MS-39; Agreement; Ocular biometric parameters; Optical biometry; CHAMBER DEPTH MEASUREMENTS; ORBSCAN IIZ; PENTACAM; THICKNESS; KERATOCONUS; PARAMETERS; IOLMASTER; DIAMETER;
D O I
10.1186/s40662-023-00330-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo assess agreement of measurements between a new optical low coherence reflectometry (OLCR) biometer (SW-9000, Suoer, Tianjin, China) and a spectral-domain optical coherence tomographer (SD-OCT)/Placido topographer (MS-39, CSO, Florence, Italy) in healthy subjects.MethodsA total of 66 right eyes from 66 healthy subjects were enrolled in this prospective study. Three consecutive measurements were randomly obtained with both devices by the same experienced operator to assess agreement. Bland-Altman plots and 95% limits of agreement (LoA) were used to verify the agreement between the devices. Results are presented as mean +/- standard deviation (SD).ResultsThe SD-OCT/Placido tomographer showed high agreement with the OLCR biometer for all parameters included in this study. The mean differences of central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), mean keratometry (Km) and corneal diameter (CD) were 2.21 +/- 2.67 mu m (P < 0.001), - 0.10 +/- 0.03 mm (P < 0.001), - 0.10 +/- 0.04 mm (P < 0.001), - 0.01 +/- 0.22 D (P = 0.773) and 0.20 +/- 0.16 mm (P < 0.001), respectively. This implies that the inter-device difference in Km was not statistically significant, while the differences in CCT, ACD, AQD, CD were statistically but not clinically significant. The 95% LoAs of CCT, ACD, AQD, Km and CD were - 3.01 to 7.44 mu m, - 0.16 to - 0.05 mm, - 0.18 to - 0.03 mm, - 0.45 to 0.43 D, and - 0.12 to 0.51 mm, respectively.ConclusionsFor CCT, ACD, AQD, Km, and CD in healthy subjects, the new OLCR biometer has high agreement with the SD-OCT/Placido tomographer and can be used interchangeably due to the narrow range of 95% LoAs.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer
    Yiran Wang
    Ting Wan
    Luze Liu
    Yuyuan Xue
    Xinyao Chen
    Giacomo Savini
    Domenico Schiano-Lomoriello
    Xingtao Zhou
    Jinjin Yu
    Jinhai Huang
    Eye and Vision, 10
  • [2] Measurement agreement between a new biometer based on partial coherence interferometry and a validated biometer based on optical low-coherence reflectometry
    Li, Junhua
    Chen, Hao
    Savini, Giacomo
    Lu, Weicong
    Yu, Xinxin
    Bao, Fangjun
    Wang, Qinmei
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01) : 68 - 75
  • [3] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Alberto Domínguez-Vicent
    Abinaya Priya Venkataraman
    Amanda Dalin
    Rune Brautaset
    Robert Montés-Micó
    Eye and Vision, 10
  • [4] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Dominguez-Vicent, Alberto
    Venkataraman, Abinaya Priya
    Dalin, Amanda
    Brautaset, Rune
    Montes-Mico, Robert
    EYE AND VISION, 2023, 10 (01)
  • [5] Agreement between a new fully automatic ocular biometer based on optical low-coherence reflectometry and an optical biometer based on Scheimpflug imaging combined with partial coherence interferometry
    Ning, Rui
    Xu, Huilin
    Li, Zheng
    Yu, Jinjin
    Xu, Shuoyu
    Lei, Chak Seng
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [6] The Precision of a New Anterior Segment Optical Coherence Tomographer and Its Comparison With a Swept-Source OCT-Based Optical Biometer in Patients With Cataract
    Wang, Qinmei
    Chen, Min
    Ning, Rui
    Savini, Giacomo
    Wang, Yiran
    Zhang, Tianjiao
    Lin, Xuanqiao
    Chen, Xin
    Huang, Jinhai
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (09) : 616 - +
  • [7] Comparison of anterior segment measurements obtained using a swept-source optical coherence tomography biometer and a Scheimpflug-Placido tomographer
    Lu, Weicong
    Li, Yue
    Savini, Giacomo
    Song, Benhao
    Hu, Qingjie
    Wang, Qinmei
    Bao, Fangjun
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (03) : 298 - 304
  • [8] Agreement of anterior ocular biometric measurements with a new optical biometer and a Scheimpflug tomographer
    McAlinden, Colm
    Bao, Fangjun
    Guo, Yan
    Yu, Xinxin
    Lu, Weicong
    Chen, Hao
    Wang, Qinmei
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (05) : 679 - 684
  • [9] Comparison of two biometers: A swept-source optical coherence tomography and an optical low-coherence reflectometry biometer
    El Chehab, Hussam
    Agard, Emilie
    Dot, Corinne
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2019, 29 (05) : 547 - 554
  • [10] Comparison of a New Scheimpflug Camera and Swept-Source Optical Coherence Tomographer for Measurements of Anterior Segment Parameters
    Huang, Xiaomin
    Lin, Xuanqiao
    Yang, Yizhou
    Yu, Jinjin
    Wang, Jiacheng
    Li, Kexin
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    OPHTHALMOLOGY AND THERAPY, 2023, 12 (06) : 3187 - 3198