Behaviour and load transfer mechanism of a novel I-beam to box-column connection

被引:3
|
作者
Goudarzi, Alireza [1 ]
Erfani, Saeed [1 ]
机构
[1] Amirkabir Univ Technol, Dept Civil Engn, 424 Hafez Ave, Tehran 158754413, Iran
关键词
Connection to box-column; Stub beam; Cyclic tests; Load transfer mechanism; Panel zone; Finite element analysis; MOMENT CONNECTIONS; SEISMIC BEHAVIOR; CFT COLUMN; RIGID CONNECTION; PERFORMANCE; END; STIFFENERS; STRENGTH; LENGTH;
D O I
10.1016/j.jcsr.2023.107809
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The recent studies on the connection of I-beam to box-column with a stub beam proposed by authors demon-strated the connection satisfactory performance. This paper discusses the load transfer mechanism of the connection. For this reason, reversed cyclic tests were conducted on the three configurations of the connection with different beam to column width ratios of 0.50, 0.67, and 0.75. The tested specimens revealed stable hys-teresis curves. Furthermore, the experimental results show that the connection is fully restrained and qualified for use in special moment frames (SMF) according to AISC. The plastic hinge developed on the beam near to beam end-plate and met the requirements of extended end-plate connections. Also, the panel zone of connection remained elastic throughout the tests. The study of load transfer mechanism revealed that by transferring the major portion of load to the column webs, the normal stress in the column flange is reduced, leading to the elimination of the need for continuity plates. Moreover, the finite element models of tested specimens were simulated. After the verification of numerical models against experimental results, they were extended to examine the effects of stub beam length and beam to column width ratio on the load transfer mechanism. Ac-cording to the numerical results, the load transfer mechanism at the stub beam to column joint location was not sensitive to the changes in stub beam length and beam to column width ratio.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Stiffness of equal width welded I-beam to RHS column connection
    López-Colina, Carlos
    Serrano, Miguel A.
    Lozano, Miguel
    Gayarre, Fernando L.
    Suárez, Jesús M.
    ce/papers, 2021, 4 (2-4) : 2459 - 2464
  • [22] An innovative I-beam to hybrid fabricated column connection: Experimental investigation
    Sadeghi, Seyed Nima
    Heidarpour, Amin
    Zhao, Xiao-Ling
    Al-Mahaidi, Riadh
    ENGINEERING STRUCTURES, 2017, 148 : 907 - 923
  • [23] Externally stiffened steel beam to box-column connections
    Ting, L.C.
    Shanmugam, N.E.
    Lee, S.L.
    Proceedings of the Steel Structures, 1600,
  • [24] Seismic behavior of an improved drilled flange connection for I-beam to CFST column
    Zhang, Yu-Jia
    Zhang, Lei
    Tong, Gen-Shu
    Chen, Ya-Fei
    Fu, Bo
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [25] The static behaviour of bolted I-beam to RHS column connections with a composite floor
    Lu, LH
    Wardenier, J
    PROCEEDINGS OF THE SEVENTH (1997) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL IV, 1997, 1997, : 70 - 77
  • [26] Modified moment connection between I-beam and double-I built-up column
    Gholipour, Masoumeh
    Deylami, Ardeshir
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2022, 15 (01): : 55 - 67
  • [27] Application of Full Depth Side Plate to Moment Connection of I-Beam to Double-I Column
    Shiravand, M. R.
    Deylami, A.
    ADVANCES IN STRUCTURAL ENGINEERING, 2010, 13 (06) : 1047 - 1062
  • [28] Modification of Moment Connection of I-Beam to Double-I Built-Up Column by Reinforcing Column Cover Plate
    Deylami, A.
    Gholipour, M.
    PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14
  • [29] Introducing new rigid I-beam to box column connections by using a stiffened channel link
    Garoosi, Allah Reza Moradi
    Roudsari, Mehrzad Tahamouli
    Torkaman, Morteza
    Bonyadirad, Shahab
    Saeedmanesh, Ali
    Soleimani, Khalil
    Lotfi, Hosein Reza
    Jowkar, Roya
    Alipour, Ali
    STEEL AND COMPOSITE STRUCTURES, 2021, 41 (04): : 533 - 548
  • [30] A steel frame connection: I-beam to SHS column via bolted T-stub
    Yemez, Kagan
    Altay, Gulay
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2010, 3 (03): : 148 - 153