Minimally invasive reconstruction of acute acromioclavicular joint injuries using the TwinBridge button system

被引:1
作者
Balke, Maurice [1 ]
Wafaisade, Arasch [2 ]
Hoeher, Juergen [1 ]
Greshake, Oliver [1 ]
机构
[1] Univ Witten Herdecke, Sportsclin Cologne, Ostmerheimer Str 200, D-51109 Cologne, Germany
[2] Univ Witten Herdecke, Cologne Merheim Med Ctr, Dept Trauma & Orthoped Surg, Cologne, Germany
关键词
Shoulder; Acromioclavicular; AC joint; Shoulder stabilization; CORACOCLAVICULAR LIGAMENT RECONSTRUCTION; ARTHROSCOPICALLY ASSISTED STABILIZATION; GERMAN TRAUMA; HOOK PLATE; INSTABILITY;
D O I
10.1007/s00590-022-03293-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Acute acromioclavicular joint (ACJ) injuries are among the most common shoulder injuries in active young adults. The most frequently used surgical treatments include the hook plate implantation and arthroscopic treatment using flip-button systems. The aim of this study was to evaluate the results of treating acute ACJ injuries using a new minimally invasive implant based on a flip-button system. Material and methods From January 2016 to October 2019, a total of 20 patients with acute ACJ injuries (1 x Type III, 3 x Type IV, 16 x Type V) underwent surgery using the Twinbridge implant (Smith & Nephew). It is a prefabricated construct consisting of two Endobuttons connected with an UltraTape. One button is placed under the coracoid using a special aiming device and two buttons are placed on the clavicle. Preoperatively, 1 day postoperatively, 3 months and at least 1 year postoperatively, patients were clinically examined and bilateral stress view and axial radiographs were obtained. At final follow-up, the simple shoulder test (SST), Taft score, Constant score, and ACJ instability (ACJI) score were recorded and a side-to-side ratio of the coracoclavicular (CC) distance was calculated. Results All 20 patients were contacted at final follow-up at a mean of 28 (min. 13, max 50) months. Six patients were not willing to come for a clinical and radiographic examination and were contacted via telephone. All six patients were free of complaints. Another two patients free of complaints refused radiographs at final follow-up. The patients presented a mean SST of 99.6% (20 patients, min. 91.7, max. 100), Taft score of 11.6/12 points (12 patients, min. 10, max. 12), ACJI of 85.5/90 points (12 patients, min. 78, max. 90), and a Constant score of 97.1 (14 patients, min. 81.0, max. 100) for the affected shoulder. Preoperative stress view images revealed a mean side-to-side difference of the CC distance with a ratio of 1:2.34 (min. 1:1.80, max. 1:3.33). At final follow-up, CC distance was calculated with a mean ratio of 1:1.12 (min. 1.1, max. 1:1.38). Axial images showed a proper position in all cases. A "perfect" radiological result was achieved in six patients (50%) with a side-to-side CC distance of less than 10% (ratio 1:1.1 or less). A Rockwood type II result was achieved in five patients (42%) with a distance of 10 to 25% (ratio 1.11-1.25). One (8%) presented with a Rockwood type III result with a difference of more than 25% (ratio 1:1.38) and was considered a radiological failure. Conclusions When used correctly, the Twinbridge implant offers good-to-excellent clinical and radiographic results using a minimally invasive surgical technique. Complication rate is comparable to other button-systems.
引用
收藏
页码:1349 / 1355
页数:7
相关论文
共 27 条
  • [1] Horizontal Instability of the Acromioclavicular Joint: A Systematic Review
    Aliberti, Gianna M.
    Kraeutler, Matthew J.
    Trojan, Jeffrey D.
    Mulcahey, Mary K.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2020, 48 (02) : 504 - 510
  • [2] Balke M, 2015, UNFALLCHIRURG, V118, P851, DOI 10.1007/s00113-013-2547-2
  • [3] Current state of treatment of acute acromioclavicular joint injuries in Germany: is there a difference between specialists and non-specialists? A survey of German trauma and orthopaedic departments
    Balke, Maurice
    Schneider, Marco M.
    Shafizadeh, Sven
    Baethis, Holger
    Bouillon, Bertil
    Banerjee, Marc
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (05) : 1447 - 1452
  • [4] Banerjee M., 2020, ACTA SCI ORTHOP, V3, P58, DOI [10.31080/ASOR.2020.03.0230, DOI 10.31080/ASOR.2020.03.0230]
  • [5] Bäthis H, 2001, UNFALLCHIRURG, V104, P955, DOI 10.1007/s001130170036
  • [6] Current Concepts in the Treatment of Acromioclavicular Joint Dislocations
    Beitzel, Knut
    Cote, Mark P.
    Apostolakos, John
    Solovyova, Olga
    Judson, Christopher H.
    Ziegler, Connor G.
    Edgar, Cory M.
    Imhoff, Andreas B.
    Arciero, Robert A.
    Mazzocca, Augustus D.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (02) : 387 - 397
  • [7] Minimally Invasive AC Joint Reconstruction System (MINAR®) in Modified Triple-Button Technique for the Treatment of Acute AC Joint Dislocation
    Breuer, Robert
    Unterrainer, Alexandra
    Komjati, Micha
    Tiefenboeck, Thomas M.
    Trieb, Klemens
    Pirkl, Christof
    [J]. JOURNAL OF CLINICAL MEDICINE, 2019, 8 (10)
  • [8] The use of hook plate in type III and V acromio-clavicular Rockwood dislocations: Clinical and radiological midterm results and MRI evaluation in 42 patients
    Di Francesco, Alexander
    Zoccali, Carmine
    Colafarina, Olivo
    Pizzoferrato, Renzo
    Flamini, Stefano
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (02): : 147 - 152
  • [9] Hook plate fixation for acromioclavicular joint separations restores coracoclavicular distance more accurately than PDS augmentation, however presents with a high rate of acromial osteolysis
    Eschler, Anica
    Gradl, Georg
    Gierer, Philip
    Mittlmeier, Thomas
    Beck, Markus
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (01) : 33 - 39
  • [10] Acromioclavicular Joint Injuries: Evidence-based Treatment
    Frank, Rachel M.
    Cotter, Eric J.
    Leroux, Timothy S.
    Romeo, Anthony A.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (17) : E775 - E788