A Comparison of CT Perfusion Output of RapidAI and Viz.ai Software in the Evaluation of Acute Ischemic Stroke

被引:2
|
作者
Bushnaq, Saif [1 ]
Hassan, Ameer E. [2 ]
Delora, Adam [4 ]
Kerro, Ali [7 ]
Datta, Anita [4 ]
Ezzeldin, Rime [8 ]
Ali, Zuhair [5 ]
Anwoju, Tunmi [5 ]
Nejad, Layla [3 ]
Silva, Rene [3 ]
Abualnadi, Yazan Diya [3 ]
Khalil, Zorain Mustafa [3 ]
Ezzeldin, Mohamad [6 ,9 ]
机构
[1] Texas Tech Univ, Hlth Sci Ctr, Dept Neurol, Lubbock, TX USA
[2] Dept Neurol, Harlingten, TX USA
[3] Valley Baptist Med Ctr Harlingen, Harlingten, TX USA
[4] HCA Houston Healthcare Kingwood, Dept Emergency Med, Kingwood, TX USA
[5] HCA Houston Healthcare Kingwood, Clin Sci, Kingwood, TX USA
[6] HCA Houston Healthcare Kingwood, Neuroendovasc Surg, Kingwood, TX USA
[7] HCA Houston Healthcare Conroe, Dept Neurol, Conroe, TX USA
[8] Jordan Univ Sci & Technol, Irbid, Jordan
[9] Hwy 59 N 405, Kingwood, TX 77339 USA
关键词
TIME; THROMBECTOMY; MANAGEMENT;
D O I
10.3174/ajnr.A8196
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Automated CTP postprocessing packages have been developed for managing acute ischemic stroke. These packages use image processing techniques to identify the ischemic core and penumbra. This study aimed to investigate the agreement of decision-making rules and output derived from RapidAI and Viz.ai software packages in early and late time windows and to identify predictors of inadequate quality CTP studies. MATERIALS AND METHODS: One hundred twenty-nine patients with acute ischemic stroke who had CTP performed on presentation were analyzed by RapidAI and Viz.ai. Volumetric outputs were compared between packages by performing Spearman rank-order correlation and Wilcoxon signed-rank tests with subanalysis performed at early (<6?hours) and extended (>6?hours) time windows. The concordance of selecting patients on the basis of DAWN and DEFUSE 3 eligibility criteria was assessed using the McNemar test. RESULTS: One hundred eight of 129 patients were found to have adequate-quality studies. Spearman rank-order correlation coefficients were calculated on time-to-maximum >6-second volume, time-to-maximum >10-second volume, CBF <30% volume, mismatch volume, and mismatch ratio between both software packages with correlation coefficients of 0.82, 0.65, 0.77, 0.78, 0.59, respectively. The Wilcoxon signed-rank test was also performed on time-to-maximum >6-second volume, time-to-maximum >10-second volume, CBF <30% volume, mismatch volume, and mismatch ratio with P values of .30, .016, <.001, .03, <.001, respectively. In a 1-sided test, CBF <30% was greater in Viz.ai (P?<!--?.001). Although this finding resulted in statistically significant differences, it did not cause clinically significant differences when applied to the DAWN and DEFUSE 3 criteria. A lower ejection fraction predicted an inadequate study in both software packages (P?=?.018; 95% CI, 0.01?0.113) and (P?=?.024; 95% CI, 0.008?0.109) for RapidAI and Viz.ai, respectively.</p--> CONCLUSIONS: Penumbra and infarct core predictions between Rapid and Viz.ai correlated but were statistically different and resulted in equivalent triage using DAWN and DEFUSE3 criteria. Viz.ai predicted higher ischemic core volumes than RapidAI. Viz.ai predicted lower combined core and penumbra values than RapidAI at lower volumes and higher estimates than RapidAI at higher volumes. Clinicians should be cautious when using different software packages for clinical decision-making.
引用
收藏
页码:863 / 870
页数:8
相关论文
共 50 条
  • [31] Application of Image Segmentation on Evaluating Infarct Core in Acute Ischemic Stroke Using CT Perfusion
    Chen, Zhong-Ping
    Shi, Ming-Chao
    Deng, Shuang-Lin
    He, Xin
    Yuan, Ting-Ting
    Ma, Yue
    Yan, Yu-Zu
    Wang, Zhuo
    Yang, Fan
    Tong, Dan
    ISICDM 2018: PROCEEDINGS OF THE 2ND INTERNATIONAL SYMPOSIUM ON IMAGE COMPUTING AND DIGITAL MEDICINE, 2018, : 138 - 142
  • [32] Prognostic Prediction Model for Endovascular Treatment of Acute Anterior Circulation Ischemic Stroke Based on Rapid Processing of PerfusIon and Diffusion Software
    Shen, Yuan
    Xu, Gang
    Shi, Haicun
    Wang, Shufang
    Zhou, Li
    Zhong, Jianguo
    Chen, Mingzhu
    Chen, Zhipeng
    Dong, Zhifeng
    WORLD NEUROSURGERY, 2025, 194
  • [33] Comparison of four different collateral scores in acute ischemic stroke by CT angiography
    Seker, Fatih
    Potreck, Arne
    Moehlenbruch, Markus
    Bendszus, Martin
    Pham, Mirko
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (11) : 1116 - 1118
  • [34] Assessment of a Bayesian Vitrea CT Perfusion Analysis to Predict Final Infarct and Penumbra Volumes in Patients with Acute Ischemic Stroke: A Comparison with RAPID
    Rava, R. A.
    Snyder, K., V
    Mokin, M.
    Waqas, M.
    Allman, A. B.
    Senko, J. L.
    Podgorsak, A. R.
    Bhurwani, M. M. Shiraz
    Hoi, Y.
    Siddiqui, A. H.
    Davies, J. M.
    Levy, E., I
    Ionita, C. N.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (02) : 206 - 212
  • [35] CT perfusion cerebral blood volume does not always predict infarct core in acute ischemic stroke
    d'Esterre, Christopher D.
    Roversi, Gloria
    Padroni, Marina
    Bernardoni, Andrea
    Tamborino, Carmine
    De Vito, Alessandro
    Azzini, Cristiano
    Marcello, Onofrio
    Saletti, Andrea
    Ceruti, Stefano
    Lee, Ting Yim
    Fainardi, Enrico
    NEUROLOGICAL SCIENCES, 2015, 36 (10) : 1777 - 1783
  • [36] Automated CT perfusion imaging for acute ischemic stroke Pearls and pitfalls for real-world use
    Vagal, Achala
    Wintermark, Max
    Nael, Kambiz
    Bivard, Andrew
    Parsons, Mark
    Grossman, Aaron W.
    Khatri, Pooja
    NEUROLOGY, 2019, 93 (20) : 888 - 898
  • [37] Higher agreement in endovascular treatment decision-making than in parametric quantifications among automated CT perfusion software packages in acute ischemic stroke
    Perez-Pelegri, Manuel
    Biarnes, Carles
    Thio-Henestrosa, Santiago
    Remollo, Sebastia
    Gimeno, Alfredo
    Cuba, Victor
    Teceno, Mikel
    Marti-Navas, Marian
    Serena, Joaquin
    Pedraza, Salvador
    Ruiz-Constantino, Juan Sebastian
    Puig, Josep
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (05) : 823 - 834
  • [38] CT Perfusion Maps Improve Detection of M2-MCA Occlusions in Acute Ischemic Stroke
    Bathla, Girish
    Maheshwarappa, Ravishankar Pillenahalli
    Soni, Neetu
    Hayakawa, Minako
    Priya, Sarv
    Samaniego, Edgar
    Ortega-Gutierrez, Santiago
    Derdeyn, Colin P.
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (06)
  • [39] Comparison of multimodal CT scan protocols used for decision-making on mechanical thrombectomy in acute ischemic stroke
    Khumtong, Rujimas
    Krings, Timo
    Pereira, Vitor M.
    Pikula, Aleksandra
    Schaafsma, Joanna D.
    NEURORADIOLOGY, 2020, 62 (03) : 399 - 406
  • [40] Two-way comparison of brain perfusion image processing software for patients with acute ischemic strokes in real-world
    Cai, Heng
    Fan, Shengyu
    Bian, Yueyan
    Yang, Qi
    Long, Zhenhai
    Chen, Liangyu
    Tang, Wei
    Zhang, Nan
    Zhen, Yongyu
    Li, Zhiqing
    NEURORADIOLOGY, 2022, 64 (01) : 161 - 169