Energy Performance Analysis and Study of an Office Building in an Extremely Hot and Cold Region

被引:3
|
作者
Liu, Yunbo [1 ]
Wang, Wanjiang [1 ]
Huang, Yumeng [1 ]
Song, Junkang [2 ]
Zhou, Zhenan [3 ]
机构
[1] Xinjiang Univ, Coll Architectural & Civil Engn, Urumqi 830017, Peoples R China
[2] Sichuan Univ, Coll Architectural & Environm, Chengdu 610000, Peoples R China
[3] North China Elect Power Univ, Sch Control & Comp Engn, Baoding 071000, Peoples R China
关键词
building energy consumption; parametric design; office buildings; entropy-based TOPSIS method; DIFFERENT CLIMATE REGIONS; DAYLIGHTING PERFORMANCE; GLAZING TECHNOLOGIES; SHADING DEVICES; WINDOWS; COMFORT; CONSUMPTION; STRATEGIES; DEPLOYMENT; SAVINGS;
D O I
10.3390/su16020572
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
China is committed to reaching peak carbon by 2030 and carbon neutrality by 2060. The goals of reducing energy consumption and building a "beautiful China" are being urgently pursued in China. The building studied in this paper is located in the city of Turpan, where the problem of excessive energy use among buildings is significant due to the region's hot summers and cold winters. Additionally, the fact that the office building studied in this paper has an east-west orientation is significant: the building's main facade is oriented to the west, comprising a large area of single-layer glass curtain wall. Based on this, this paper proposes optimization strategies from two perspectives of renovation and new construction. Four design options are proposed at the retrofit level: glazed circular curtain wall; glazed enclosed curtain wall; west-facing double-glazed curtain wall circulation combined with south-facing light from the east; recycling of windows on the inside of the exterior glass curtain wall. These suggestions focus on retrofitting the glass curtain wall on the west elevation of the building. Two design options are proposed at the new-build level: west-facing south-oriented light and west-facing north-oriented light. These suggestions were primarily built around the idea of changing the orientation of the windows on the west elevation. The results show that the optimal solution is to implement the west-facing double-glazed curtain wall circulation combined with south-facing light from the east. This program shows a 64.14% reduction in heating energy consumption, a 77.12% reduction in cooling energy consumption, and a 69.67% reduction in total energy consumption. The above research has improved the deficiencies in the performance-based energy efficiency retrofit of office buildings in the region and provided new ideas and suggestions for policymakers and designers to build energy-efficiency retrofits in the early stages.
引用
收藏
页数:29
相关论文
共 50 条
  • [1] Prediction and Optimization Analysis of the Performance of an Office Building in an Extremely Hot and Cold Region
    Liu, Yunbo
    Wang, Wanjiang
    Huang, Yumeng
    SUSTAINABILITY, 2024, 16 (10)
  • [2] Study and analysis of office building energy consumption performance in severe cold and cold region, China
    Ding, Zequn
    Zhu, Hongqing
    Wang, Yang
    Ge, Xiaoling
    ADVANCES IN MECHANICAL ENGINEERING, 2017, 9 (11):
  • [3] Case analysis of energy consumption of the existing office building in the severe cold region
    Ma Chuan
    Liu Jiajia
    Cui Guangfu
    Manglink, R. N.
    APPLIED MATHEMATICS AND NONLINEAR SCIENCES, 2021, 6 (01) : 211 - 218
  • [4] Adaptability Analysis of Passive Building Energy Efficiency Technology in Hot Summer and Cold Winter Region
    Tong, Qing-gui
    SUSTAINABLE DEVELOPMENT AND ENVIRONMENT II, PTS 1 AND 2, 2013, 409-410 : 651 - 654
  • [5] Sensitivity Analysis and Optimization of Energy-Saving Measures for Office Building in Hot Summer and Cold Winter Regions
    Xuanyuan, Peisong
    Zhang, Yijie
    Yao, Jian
    Zheng, Rongyue
    ENERGIES, 2024, 17 (07)
  • [6] Study on Daylighting and Energy Conservation Design of Transparent Envelope for office building in Hot Summer and Cold Winter Zone
    Yu, Jinghua
    Liu, Yu
    Xiong, Chao
    Huang, Jun Chao
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 1642 - 1649
  • [7] The performance and analysis of office building energy consumption in the west of Inner Mongolia Autonomous Region, China
    Lu, Shilei
    Zheng, Shaoqun
    Kong, Xiangfei
    ENERGY AND BUILDINGS, 2016, 127 : 499 - 511
  • [8] Energy Conservation for an Office Building in a Hot Climate
    Dalal, Hari S.
    THIRD INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN - MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2018, : 240 - 245
  • [9] Air conditioning energy consumption measurement and saving strategy analysis for an office building in hot summer and cold winter area
    Ran, Bin
    Qiu, Shuting
    Zhang, Ying
    Zeng, Li
    Zhu, Jianming
    Xiang, Zhifeng
    Long, Jibo
    ADVANCES IN BUILDING ENERGY RESEARCH, 2023, 17 (01) : 73 - 97
  • [10] Energy performance analysis of an office building in three climate zones
    Jung, Nusrat
    Paiho, Satu
    Shemeikka, Jari
    Lahdelma, Risto
    Airaksinen, Miimu