Comparison of Drug-Coated Balloon and Drug-Eluting Stent for the Treatment of Small Vessel Disease (from the Dissolve SVD Randomized Trial)

被引:2
|
作者
Liu, Shengwen [1 ]
Zhou, Yujie [2 ]
Shen, Zhujun [3 ]
Chen, Hui [4 ]
Qiu, Chunguang [5 ]
Fu, Guosheng [6 ]
Li, Hui [7 ]
Yu, Zaixin [8 ]
Zeng, Qiutang [9 ]
Li, Zhanquan [10 ]
Li, Wei [11 ]
Qiao, Shubin [1 ]
机构
[1] Fu Wai Hosp, Dept Cardiol, Beijing, Peoples R China
[2] Beijing Anzhen Hosp, Dept Cardiol, Beijing, Peoples R China
[3] Peking Union Med Coll Hosp, Dept Cardiol, Beijing, Peoples R China
[4] Capital Med Univ, Beijing Friendship Hosp, Dept Cardiol, Beijing, Peoples R China
[5] Zheng Zhou Univ, Affiliated Hosp 1, Dept Cardiol, Zhengzhou, Peoples R China
[6] Zhejiang Univ, Dept Cardiol, Sir Run Run Shaw, Sch Med, Hangzhou, Zhejiang, Peoples R China
[7] Daqing Oilfield Gen Hosp, Dept Cardiol, Daqing, Peoples R China
[8] Cent South Univ, Xiangya Hosp, Dept Cardiol, Changsha, Peoples R China
[9] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Cardiol, Wuhan, Peoples R China
[10] Liaoning Prov Peoples Hosp, Dept Cardiol, Shenyang, Peoples R China
[11] Natl Ctr Cardiovasc Dis China, Med Res & Biometr Ctr, Beijing, Peoples R China
关键词
CORONARY-ARTERY-DISEASE; 3-YEAR FOLLOW-UP; MULTICENTER; EVEROLIMUS; SYSTEM; IMPACT;
D O I
10.1016/j.amjcard.2023.05.057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Dissolve drug-coated balloons (DCBs) is a new-generation DCB coated with paclitaxel of balloon surface, with midchain triglyceride excipient. Although the use of DCBs is a promising technique, little is known about the the clinical efficacy of the novel Dissolve DCB in coronary small vessel disease. This study was a prospective, randomized, multicenter, noninferiority trial comparing the Dissolve DCB with the Resolute drug-eluting stent (DES) in patients with a reference vessel diameter >= 2.25 and <= 2.75 mm. Patients with a reference vessel diameter >= 2.00 and <2.25 mm were enrolled in the very small vessel registry. The angiographic and clinical follow-up were planned at 9 months and 1 year in all patients, respectively. The primary end point was 9-month in-segment percentage diameter stenosis. A total of 247 patients with small vessel disease from 10 Chinese sites were included (Dissolve DCB, n = 118; Resolute DES, n = 129); 30 patients were treated with the DCB in the very small vessel cohort. The 9-month in-segment percentage diameter stenosis was 31.2 +/- 2.0% with Dissolve DCB versus 26.1 +/- 2.1% with Resolute DES; the 1-sided 97.5% upper confidence limit of the difference was 10.3% (p for noninferiority = 0.0002). At 12 months, the DCB and DES groups were associated with similar rates of target lesion failure (8.5% vs 6.1%, p = 0.28) and major adverse cardiac and cerebrovascular events (20.9% vs 13.6%, p = 0.12). In conclusion, the Dissolve DCB was noninferior to the Resolute DES for the primary end point of 9-month in-segment percentage diameter stenosis in this multicenter, head-to-head, randomized trial (a safety and efficacy study of Dissolve In Treatment Of Coronary Small Vessel Disease; NCT03376646). (c) 2023 Published by Elsevier Inc. (Am J Cardiol 2024;211:29-39)
引用
收藏
页码:29 / 39
页数:11
相关论文
共 50 条
  • [1] Drug-Coated Balloon Versus Drug-Eluting Stent for Small-Vessel Disease The RESTORE SVD China Randomized Trial
    Tang, Yida
    Qiao, Shubin
    Su, Xi
    Chen, Yundai
    Jin, Zening
    Chen, Hui
    Xu, Biao
    Kong, Xiangqing
    Pang, Wenyue
    Liu, Yong
    Yu, Zaixin
    Li, Xue
    Li, Hui
    Zhao, Yanyan
    Wang, Yang
    Li, Wei
    Tian, Jian
    Guan, Changdong
    Xu, Bo
    Gao, Runlin
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (23) : 2381 - 2392
  • [2] Drug-Coated Balloon Versus Drug-Eluting Stent for Small Coronary Vessel Disease PICCOLETO II Randomized Clinical Trial
    Cortese, Bernardo
    Di Palma, Gaetano
    Guimaraes, Marcos Garcia
    Piraino, Davide
    Orrego, Pedro Silva
    Buccheri, Dario
    Rivero, Fernando
    Perotto, Anna
    Zambelli, Giulia
    Alfonso, Fernando
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (24) : 2840 - 2849
  • [3] Comparison of drug-eluting stents and drug-coated balloon for the treatment of drug-eluting coronary stent restenosis: A randomized RESTORE trial
    Wong, Yiu Tung Anthony
    Kang, Do-Yoon
    Lee, Jin Bae
    Rha, Seung-Woon
    Hong, Young Joon
    Shin, Eun-Seok
    Her, Sung-Ho
    Nam, Chang Wook
    Chung, Woo-Young
    Kim, Moo Hyun
    Lee, Cheol Hyun
    Lee, Pil Hyung
    Ahn, Jung-Min
    Kang, Soo-Jin
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Park, Seong-Wook
    Park, Duk-Woo
    Park, Seung-Jung
    AMERICAN HEART JOURNAL, 2018, 197 : 35 - 42
  • [4] Comparison between drug-coated balloon angioplasty and second-generation drug-eluting stent placement for the treatment of in-stent restenosis after drug-eluting stent implantation
    Kang, In Sook
    Shehata, Islam
    Shin, Dong-Ho
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    HEART AND VESSELS, 2016, 31 (09) : 1405 - 1411
  • [5] Drug-coated balloon versus drug-eluting stent in de novo small coronary vessel disease A systematic review and meta-analysis
    Li, Min
    Guo, Chen
    Lv, Yong-Hui
    Zhang, Ming-Bo
    Wang, Zhi-Lu
    MEDICINE, 2019, 98 (21)
  • [6] Drug-coated balloon angioplasty for drug-eluting stent restenosis: Insight from randomized controlled trials
    Mamuti, Wahafu
    Jiamali, Abulimiti
    Rao, Fang
    Zhang, Wei
    Pei, Xiaoli
    Ablimit, Alimjan
    Kelimu, Wumaierjiang
    Zhang, Feng
    ANNALS OF MEDICINE, 2014, 46 (08) : 679 - 683
  • [7] Drug-Coated Balloon versus Drug-Eluting Stent in Patients with Small-Vessel Coronary Artery Disease: A Meta-Analysis of Randomized Controlled Trials
    Wu, Xinying
    Li, Lun
    He, Li
    CARDIOLOGY RESEARCH AND PRACTICE, 2021, 2021
  • [8] Two-year follow-up of a randomized multicenter study comparing a drug-coated balloon with a drug-eluting stent in native small coronary vessels: The RESTORE Small Vessel Disease China trial
    Tian, Jian
    Tang, Yi-da
    Qiao, Shubin
    Su, Xi
    Chen, Yundai
    Jin, Zening
    Chen, Hui
    Xu, Biao
    Kong, Xiangqing
    Pang, Wenyue
    Liu, Yong
    Yu, Zaixin
    Li, Xue
    Li, Hui
    Zhao, Yanyan
    Wang, Yang
    Li, Wei
    Guan, Changdong
    Gao, Runlin
    Xu, Bo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 : 587 - 597
  • [9] Comparison between drug-coated balloon angioplasty and second-generation drug-eluting stent placement for the treatment of in-stent restenosis after drug-eluting stent implantation
    In Sook Kang
    Islam Shehata
    Dong-Ho Shin
    Jung-Sun Kim
    Byeong-Keuk Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    Heart and Vessels, 2016, 31 : 1405 - 1411
  • [10] Nationwide trends in drug-coated balloon and drug-eluting stent utilization in the femoropopliteal arteries
    Mohapatra, Abhisekh
    Saadeddin, Zein
    Bertges, Daniel J.
    Madigan, Michael C.
    Al-Khoury, Georges E.
    Makaroun, Michel S.
    Eslami, Mohammad H.
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (02) : 560 - 566