Comparison of linear and angular measurements in mandibular symphyseal region using lateral cephalometric and cone beam CT images

被引:1
作者
Baydar, Oguzhan [1 ]
Onem, Erinc [1 ]
Baksi, B. Guniz [1 ]
机构
[1] Ege Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Izmir, Turkiye
关键词
cone beam CT; lateral cephalometry; mandibular symphysis; COMPUTED-TOMOGRAPHY; ACCURACY; RELIABILITY; IDENTIFICATION; CBCT;
D O I
10.1002/osi2.1212
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the linear and angular measurements of the mandibular symphyseal region using lateral cephalometric (LC) and cone beam computed tomography (CBCT) images.Materials and Methods One hundred patients justifying both LC and CBCT exposures were included. Both lateral cephalometric and CBCT images of the patients were used for angular and linear measurements. Angular measurements included vestibular concavity and lingual and tooth inclination angles. Vestibular and lingual cortical bone and total bone thickness measurements were obtained for the comparison of linear measurements. Three radiologists performed the measurements on 200 images. Comparison of the measurements and the imaging methods were done using paired- and Wilcoxon t-tests. Inter-observer reliability was evaluated with the intra-class correlation coefficient (ICC).Results A significant difference was observed between measurements of two imaging methods for tooth inclination and vestibular concavity angles; however, no difference was found between LC and CBCT measurements for lingual inclination angle (p > 0.05). Vestibular cortical bone and total bone thickness measurements showed a significant difference (p < 0.05), whereas no difference was obtained in lingual bone thickness measurements of two imaging methods (p > 0.05).Conclusion CBCT imaging is recommended in selected patients where recipient bone or bone augmentation site(s) reveal suspect in clinical examination and lateral cephalometric imaging may not reveal the true anatomic structure and relationships.
引用
收藏
页码:237 / 243
页数:7
相关论文
共 50 条
  • [31] Comparison of patient megavoltage cone beam CT images acquired with an unflattened beam from a carbon target and a flattened treatment beam
    Faddegon, Bruce A.
    Aubin, Michele
    Bani-Hashemi, Ali
    Gangadharan, Bijumon
    Gottschalk, Alexander R.
    Morin, Olivier
    Sawkey, Daren
    Wu, Vincent
    Yom, Sue S.
    MEDICAL PHYSICS, 2010, 37 (04) : 1737 - 1741
  • [32] Comparison of Airway Measurements in Rheumatoid Arthritis and Non-rheumatoid Patients using Lateral Cephalometric Radiographs
    Badr, F. F.
    Jadu, F. M.
    Nasir, A. M.
    Jan, A. M.
    Wali, S.
    Mustafa, M.
    Bawazin, Y.
    Meisha, D.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2021, 24 (08) : 1200 - 1205
  • [33] Comparison of height and width measurements of mandibular bone in various head orientations using cone beam computed tomography: an experimental in vitro study
    Kajan, Zahra Dalili
    Asli, Hamid Neshandar
    Taramsari, Mehran
    Chai, Seyed Mokhtar Fallah
    Hemmaty, Yasamin Babaei
    ORAL RADIOLOGY, 2015, 31 (01) : 28 - 35
  • [34] Do CBCT scans alter surgical treatment plans? Comparison of preoperative surgical diagnosis using panoramic versus cone-beam CT images
    Wolff, Carolina
    Muecke, Thomas
    Wagenpfeil, Stefan
    Kanatas, Anastasios
    Bissinger, Oliver
    Deppe, Herbert
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (10) : 1700 - 1705
  • [35] Measurements of mandibular canal region obtained by cone-beam computed tomography: a cadaveric study
    Kamburoglu, Kivanc
    Kilic, Cenk
    Oezen, Tuncer
    Yueksel, Selcen Pehlivan
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (02): : E34 - E42
  • [36] Comparison between cone-beam CT and multidetector-row CT by ROC analysis regarding diagnostic accuracy for artificial alveolar bone defects in the mandibular molar region
    Minami, Seiji
    Ohnishi, Takashi
    Sano, Tomoaki
    Sugiura, Kazutaka
    Nakayama, Eiji
    ORAL RADIOLOGY, 2015, 31 (02) : 97 - 104
  • [37] Accuracy of conventional versus cone-beam CT-synthesised lateral cephalograms for cephalometric analysis: A systematic review
    Raj, Grace
    Raj, Mary
    Saigo, Leonardo
    JOURNAL OF ORTHODONTICS, 2024, 51 (02) : 160 - 176
  • [38] Evaluation of horizontal condylar angle in malocclusions with mandibular lateral displacement using cone-beam computed tomography
    Velasquez, Roberto L.
    Coro, Jorge C.
    Bustillo, Jose M.
    Sato, Sadao
    ANGLE ORTHODONTIST, 2021, 91 (06) : 815 - 821
  • [39] A Quantitative Analysis of Breast Densities Using Cone Beam CT Images
    Benitez, Ricardo Betancourt
    Ning, Ruola
    Conover, David
    Liu, Shaohua
    MEDICAL IMAGING 2009: COMPUTER-AIDED DIAGNOSIS, 2009, 7260
  • [40] Accuracy of Linear Measurements Using Cone Beam Computed Tomography and Panoramic Radiography in Dental Implant Treatment Planning
    Luangchana, Penporn
    Pornprasertsuk-Damrongsri, Suchaya
    Kiattavorncharoen, Sirichai
    Jirajariyavej, Bundhit
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (06) : 1287 - 1294