Nonenhanced Photon Counting CT of the Head Impact of the keV Level, Iterative Reconstruction and Calvaria on Image Quality in Monoenergetic Images

被引:4
|
作者
Michael, Arwed Elias [1 ,3 ]
Schoenbeck, Denise [1 ]
Woeltjen, Matthias Michael [1 ]
Boriesosdick, Jan [1 ]
Kroeger, Jan Robert [1 ]
Moenninghoff, Christoph [1 ]
Horstmeier, Sebastian [1 ]
Niehoff, Julius Henning [1 ]
Kabbasch, Christoph [2 ]
Goertz, Lukas [2 ]
Borggrefe, Jan [1 ]
机构
[1] Ruhr Univ Bochum, Johannes Wesling Univ Hosp, Dept Radiol Neuroradiol & Nucl Med, Bochum, Germany
[2] Univ Hosp Cologne, Dept Radiol & Neuroradiol, Cologne, Germany
[3] Johannes Wesling Univ Hosp Muehlenkreiskliniken Ao, Hans Nolte Str 1, D-32429 Minden, Germany
关键词
Computed tomography; Photon counting detector; Nonenhanced CT of the head; Virtual monoenergetic images; Iterative reconstruction; Quantum iterative reconstruction; DETECTOR CT; REDUCTION; ARTIFACTS;
D O I
10.1007/s00062-023-01331-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeNonenhanced computed tomography (CT) of the head is among the most commonly performed CT examinations. The spectral information acquired by photon counting CT (PCCT) allows generation of virtual monoenergetic images (VMI). At the same time, image noise can be reduced using quantum iterative reconstruction (QIR). In this study, the image quality of VMI was evaluated depending on the keV level and the QIR level. Furthermore, the influence of the cranial calvaria was investigated to determine the optimal reconstruction for clinical application.MethodsA total of 51 PCCT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) of the head were retrospectively analyzed. In a quantitative analysis, gray and white matter ROIs were evaluated in different brain areas at all available keV levels and QIR levels with respect to signal, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The distance to the cranial calvaria of the ROIs was included in the analysis. This was followed by a qualitative reading by five radiologists including experienced neuroradiologists.ResultsIn most ROIs, signal and noise varied significantly between keV levels (p < 0.0001). The CNR had a focal maximum at 66 keV and an absolute maximum at higher keV, slightly differently located depending on ROI and QIR level. With increasing QIR level, a significant reduction in noise was achieved (p < 0.0001) except just beneath the cranial calvaria. The cranial calvaria had a strong effect on the signal (p < 0.0001) but not on gray and white matter noise. In the qualitative reading, the 60 keV VMI was rated best.ConclusionIn nonenhanced PCCT of the head the selected keV level of the VMI and the QIR level have a crucial influence on image quality in VMI. The 60 keV and 66 keV VMI with high QIR level provided optimal subjective and objective image quality for clinical use. The cranial calvaria has a significant influence on the visualization of the adjacent brain matter; currently, this substantially limits the use of low keV VMIs (< 60 keV).
引用
收藏
页码:75 / 83
页数:9
相关论文
共 50 条
  • [41] Evaluation of thin-slice abdominal DECT using deep-learning image reconstruction in 74 keV virtual monoenergetic images: an image quality comparison
    Jack J. Xu
    Lars Lönn
    Esben Budtz-Jørgensen
    Samir Jawad
    Peter S. Ulriksen
    Kristoffer L. Hansen
    Abdominal Radiology, 2023, 48 : 1536 - 1544
  • [42] Combining iterative metal artifact reduction and virtual monoenergetic images severely reduces hip prosthesis-associated artifacts in photon-counting detector CT
    Layer, Yannik C.
    Mesropyan, Narine
    Kupczyk, Patrick A.
    Luetkens, Julian A.
    Isaak, Alexander
    Dell, Tatjana
    Attenberger, Ulrike I.
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [43] Standard and Reduced Radiation Dose Liver CT Images: Adaptive Statistical Iterative Reconstruction versus Model-based Iterative Reconstruction-Comparison of Findings and Image Quality
    Shuman, William P.
    Chan, Keith T.
    Busey, Janet M.
    Mitsumori, Lee M.
    Choi, Eunice
    Koprowicz, Kent M.
    Kanal, Kalpana M.
    RADIOLOGY, 2014, 273 (03) : 793 - 800
  • [44] Venous-phase chest CT with reduced contrast medium dose: Utilization of spectral low keV monoenergetic images improves image quality
    Hickethier, Tilman
    Kroeger, Jan Robert
    Lennartz, Simon
    Doerner, Jonas
    Maintz, David
    Chang, De-Hua
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 122
  • [45] Virtual Monochromatic Reconstruction of Dual-Energy Unenhanced Head CT at 65-75 keV Maximizes Image Quality Compared with Conventional Polychromatic CT
    Pomerantz, Stuart R.
    Kamalian, Shervin
    Zhang, Da
    Gupta, Rajiv
    Rapalino, Otto
    Sahani, Dushyant V.
    Lev, Michael H.
    RADIOLOGY, 2013, 266 (01) : 318 - 325
  • [46] Improvement of Image Quality in Unenhanced Dual-Layer CT of the Head Using Virtual Monoenergetic Images Compared With Polyenergetic Single-Energy CT
    Neuhaus, Victor
    Abdullayev, Nuran
    Hokamp, Nils Grosse
    Pahn, Gregor
    Kabbasch, Christoph
    Mpotsaris, Anastasios
    Maintz, David
    Borggrefe, Jan
    INVESTIGATIVE RADIOLOGY, 2017, 52 (08) : 470 - 476
  • [47] Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality - preliminary findings
    Mieville, Frederic A.
    Gudinchet, Francois
    Rizzo, Elena
    Ou, Phalla
    Brunelle, Francis
    Bochud, Francois O.
    Verdun, Francis R.
    PEDIATRIC RADIOLOGY, 2011, 41 (09) : 1154 - 1164
  • [48] Impact of Model-Based Iterative Reconstruction on Image Quality of Contrast-Enhanced Neck CT
    Gaddikeri, S.
    Andre, J. B.
    Benjert, J.
    Hippe, D. S.
    Anzai, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) : 391 - 396
  • [49] Paediatric cardiac CT examinations: impact of the iterative reconstruction method ASIR on image quality – preliminary findings
    Frédéric A. Miéville
    François Gudinchet
    Elena Rizzo
    Phalla Ou
    Francis Brunelle
    François O. Bochud
    Francis R. Verdun
    Pediatric Radiology, 2011, 41 : 1154 - 1164
  • [50] Impact of 80 kVp with iterative reconstruction algorithm and low-dose contrast medium on the image quality of craniocervical CT angiography
    Chen, Po-An
    Chen, Chih-Wei
    Chou, Chiung-Chen
    Fu, Jui-Hsun
    Wang, Po-Chin
    Hsu, Shuo-Hsiu
    Lai, Ping-Hong
    CLINICAL IMAGING, 2020, 68 (68) : 124 - 130