Internal organ dose rate conversion coefficients of Japanese macaques to 134Cs,137Cs and 131I
被引:2
|作者:
Takamura, Yuta
[1
]
Kajimoto, Tsuyoshi
[1
]
Tanaka, Kenichi
[2
]
Yamamoto, Tomoya
[1
]
Suzuki, Masatoshi
[3
,4
]
Inaba, Yohei
[3
,4
]
Chida, Koichi
[3
,4
]
Fukumoto, Manabu
[3
,5
]
Rangacharyulu, Chary
[6
]
Endo, Satoru
[1
]
机构:
[1] Hiroshima Univ, Grad Sch Adv Sci & Engn, Quantum Energy Applicat, 1-4-1 Kagamiyama, Higashihiroshima 7398527, Japan
[2] Kyoto Pharmaceut Univ, Div Liberal Arts Sci, Lab Phys, 5, Misasagi Nakauchi Cho,Yamashina Ku, Kyoto 6078414, Japan
[3] Tohoku Univ, Int Res Inst Disaster Sci, Radiol Disasters & Med Sci Lab, 519-1176 Aramaki Aza Aoba,Aoba Ku, Sendai 9800845, Japan
[4] Tohoku Univ Grad Sch Med, Course Radiol Technol, Hlth Sci, 2-1 Seiryo Machi,Aoba Ku, Sendai 9808575, Japan
[5] RIKEN Ctr Adv Intelligence Project, Pathol Informat Team, Chuo Ku, Tokyo 1030027, Japan
[6] Univ Saskatchewan, Dept Phys & Engn Phys, Saskatoon, SK S7N 5E2, Canada
关键词:
internal exposure;
internal exposure rate conversion coefficient;
absorbed fraction;
Cs-137;
Cs-134;
I-131;
D O I:
10.1093/jrr/rrad055
中图分类号:
Q [生物科学];
学科分类号:
07 ;
0710 ;
09 ;
摘要:
The purpose of this study was to estimate the internal dose of radiation in Japanese macaques (aka Nihonzaru or snow monkey) due to the Fukushima nuclear power plant accident. Images of a male Japanese macaque weighing similar to 10 kg were acquired using a multi -slice computed tomography (CT) scan with a 64-row segment detector. The CT images were used to create voxel phantoms of the bones, bone marrow, brain, eyes, heart, lungs, stomach, liver, spleen, pancreas, kidneys, intestines, bladder, testes, thyroid and miscellaneous tissue. The Particle and Heavy Ion Transport System (PHITS) Monte Carlo code was used to calculate the internal exposure rate conversion factors for Cs-134, Cs-137 and I-131 isotopes for the created voxel phantoms with a statistical precision higher than 1%. The PHITS-calculated energy deposits were compared with those for rhesus monkeys. The results showed that the fractions of energy deposits for beta -radiation in different organs were almost identical between the two species. For gamma -radiation, there was excellent agreement in the self-absorption rate with the approximate curve of the Japanese macaque, with an average deviation of 2%. The maximum deviation of 12% was for the kidney, which has two organs, so the error with the approximate curve is slightly larger due to the energy loss created between organs.
引用
收藏
页码:804 / 810
页数:7
相关论文