Dose optimization of adult head computed tomography examination in an academic hospital in Ghana

被引:4
作者
Anim-Sampong, Samuel [1 ]
Ohene-Botwe, Benard [1 ,2 ]
Adom, Esther Boatemaa [1 ]
Tagoe, Samuel Nii Adu [1 ]
机构
[1] Univ Ghana, Sch Biomed & Allied Hlth Sci, Dept Radiog, POB KB 14,Korle Bu Campus, Accra, Ghana
[2] City Univ London, Sch Hlth & Psychol Sci, Dept Midwifery & Radiog, Northampton Sq, London EC1V 0HB, England
关键词
Patients; Computed tomography; Dose optimization; Image quality; DIAGNOSTIC REFERENCE LEVELS; CT; RADIATION; REDUCTION; RISK;
D O I
10.1016/j.radphyschem.2022.110735
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The study investigated radiation doses and image quality of adult head CT and optimization options using an anthropomorphic RANDO phantom on the only available AquilionONE CT scanner in Ghana. Dose length product (DLP) and volume-weighted CT dose index (CTDIvol) dose descriptors were retrospectively obtained from 402 adult head CT examinations performed (from 2020 to 2021) at a Ghanaian hospital, while the effective dose (Deff) was estimated from the product of the DLP and a convention coefficient (k = 0.0023). Using the same routine head CT protocol, the anthropomorphic RANDO phantom was scanned with the hospital's 640-slice Toshiba AquilionONE CT scanner. Subsequently, exposure factors were varied to study their effects on the dose and image quality. The adult head and phantom images were obtained in Digital Imaging and Communi-cations in Medicine (DICOM) format, and their signal-to-noise (SNR) ratios were analyzed with ImageJ software. The facility's mean CTDIvol, DLP, and effective dose (Deff) were 86.00 +/- 0.00 mGy, 1559.68 +/- 197.18 mGy cm, and 3.57 +/- 0.46 mSv respectively (SNR = 7.04). For a fixed tube potential, CTDIvol, DLP, and Deff of 51.30 mGy, 1013.80 mGy cm, and 2.33 mSv were respectively achieved (SNR = 5.49) after optimization. Using automatic exposure control (AEC) in the optimization process, the respective CTDIvol, DLP and Deff values were 59.50 mGy, 1176.00 mGy cm and 2.70 mSv (SNR = 5.62). We conclude that substantial Deff reductions of 40.4% and 31.0% using a fixed tube potential, and AEC while maintaining diagnostic image quality were respectively achieved. The protocols associated with these dose-reductions are, therefore, recommended as optimization measures for head CT on the AquilionONE scanner in Ghana.
引用
收藏
页数:6
相关论文
共 38 条
[1]  
Akyea-Larbi K.O., 2015, THESIS U GHANA
[2]  
Alm-Carlsson G., 2007, IAEA TECHNICAL REPOR
[3]  
Anim-Sampong S., 2016, SAFETY HEALTH, V2, P1, DOI [10.1186/s40886-016-0019-4, DOI 10.1186/S40886-016-0019-4]
[4]  
[Anonymous], 2008, ACR PRACT GUID DIAGN
[5]   CT dosimetry: comparison of measurement techniques and devices [J].
Bauhs, John A. ;
Vrieze, Thomas J. ;
Primak, Andrew N. ;
Bruesewitz, Michael R. ;
McCollough, Cynthia H. .
RADIOGRAPHICS, 2008, 28 (01) :245-253
[6]  
Bongartz G., 2000, EUROPEAN GUIDELINES
[7]   An Investigation into the Infrastructure and Management of Computerized Tomography Units in Ghana [J].
Botwe, Benard ;
Schandorf, Cyril ;
Inkoom, Stephen ;
Faanu, Augustine .
JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2020, 51 (01) :165-172
[8]   National indication-based diagnostic reference level values in computed tomography: Preliminary results from Ghana [J].
Botwe, Benard Ohene ;
Schandorf, Cyril ;
Inkoom, Stephen ;
Faanu, Augustine ;
Rolstadaas, Linn ;
Goa, Pal Erik .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 :274-284
[9]   How to Appropriately Calculate Effective Dose for CT Using Either Size-Specific Dose Estimates or Dose-Length Product [J].
Brady, Samuel L. ;
Mirro, Amy E. ;
Moore, Bria M. ;
Kaufman, Robert A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (05) :953-958
[10]   The Rose model, revisited [J].
Burgess, AE .