In vitro comparison of the color degradation of two computer-aided design/computer-aided manufacturing provisional materials: A 12-month simulation

被引:2
作者
Sayegh, Suzanna Maria [1 ,3 ]
Daou, Maha [2 ]
Najjar, Georges [1 ]
Zebouni, Elie [1 ]
机构
[1] St Joseph Univ Beirut, Dept Prosthodont, Beirut, Lebanon
[2] St Joseph Univ Beirut, McGill Univ, Dept Pediat, Beirut, Lebanon
[3] St Joseph Univ, Beirut, Lebanon
关键词
Color; composite resin; computer-aided manufacturing; in vitro; materials; polymethyl methacrylate; stability; temporary; STABILITY; IMMERSION; CAD/CAM;
D O I
10.4103/jips.jips_119_22
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This study evaluated the color aging of two computer aided design/computer aided manufacturing (CAD/CAM) provisional materials of different compositions (polymethyl methacrylate and composite resin) after exposure to thermal aging and immersion in coffee for 3, 6, and 12 intraoral months. Setting and Design: The current in vitro study was conducted from September to December 2021 at the Craniofacial laboratory at the Saint Joseph University in Beirut, Lebanon. Materials and Methods: The shades of 2.0 mm thick, 10.0 mm in diameter disk shaped specimens of VITA CAD Temp (R) and Ceramill (R) TEMP were measured using the VITA Linearguide 3D MASTER (R) and a conversion table to extract the CIE L*a*b* values on a white background (n = 30). Statistical Analysis Used: The color differences ?E at 3, 6, and 12 months were calculated and analyzed by repeated measures ANOVA followed by Bonferroni multiple comparisons, univariate analyses, and one sample t tests. Results: The mean ?ET1/T0, ?E-T2/T0, and ?E-T3/T0 values were significantly higher than the cutoff values for acceptability and perceptibility for the VITA CAD Temp (R) and the Ceramill (R) TEMP groups. In addition, the increase in ?E overtime was significantly greater in the Ceramill (R) TEMP group compared to the VITA CAD Temp (R) group. Conclusions: The Ceramill (R) TEMP changed color more and faster than the VITA CAD Temp (R). In addition, whether at 3, 6, or 12 months, the color variations of both materials are not only perceptible but also unacceptable compared to the initial shade.
引用
收藏
页码:38 / 44
页数:7
相关论文
共 25 条
[1]  
Almohareb Thamer, 2018, Eur J Dent, V12, P269, DOI [10.4103/ejd.ejd_1_18, 10.4103/ejd.ejd_1_18]
[2]   Influence of thermomechanical aging on marginal gap of CAD-CAM and conventional interim restorations [J].
Angwarawong, Thidarat ;
Reeponmaha, Tanapon ;
Angwaravong, Onauma .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (05) :566.e1-566.e6
[3]  
Chbeir Rouba MM, 2017, LEBANESE COFFEE MARK
[4]  
Christian Pignoly VA., 2010, COLOR MEASUREMENT CO
[5]  
Comisi John C, 2015, Compend Contin Educ Dent, V36, P56
[6]  
da Costa IA, 2018, BRAZ J ORAL SCI, V17
[7]   In vitro color stability of provisional crown and bridge restoration materials [J].
Ergün, G ;
Mutlu-Sagesen, L ;
Özkan, Y ;
Demirel, E .
DENTAL MATERIALS JOURNAL, 2005, 24 (03) :342-350
[8]   Thermal cycling procedures for laboratory testing of dental restorations [J].
Gale, MS ;
Darvell, BW .
JOURNAL OF DENTISTRY, 1999, 27 (02) :89-99
[9]  
Gratton D.G. Aquilino., 2004, Dental Clinics of North America, V48, P487, DOI [10.1016/j.cden.2003.12.007, DOI 10.1016/J.CDEN.2003.12.007]
[10]   Effects of different drinks on stainability of resin composite provisional restorative materials [J].
Guler, AU ;
Yilmaz, F ;
Kulunk, T ;
Guler, E ;
Kurt, S .
JOURNAL OF PROSTHETIC DENTISTRY, 2005, 94 (02) :118-124