Subcooling effect on the optimal performance for a transcritical CO2 heat pump with cold thermal energy storage

被引:17
作者
Wang, Ji [1 ]
Evans, Michael [2 ]
Belusko, Martin [3 ]
Zhao, Chunrong [4 ]
Liu, Ming [1 ]
Bruno, Frank [1 ]
机构
[1] Univ South Australia, Future Ind Inst, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia
[2] Univ South Australia, UniSA STEM, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia
[3] Mondial Advisory, Malvern, SA 5061, Australia
[4] Univ Sydney, Sch Aerosp Mech & Mechatron Engn, Darlington, NSW 2006, Australia
关键词
Transcritical CO2 heat pump; Subcooling effect; Simultaneous heating and cooling; Cold thermal energy storage; CARBON-DIOXIDE; REFRIGERATION SYSTEM; TEMPERATURE; CYCLE; OPTIMIZATION; EXCHANGER; PRESSURE; EQUATION; LIQUID; PLANT;
D O I
10.1007/s00231-022-03333-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper studies the combined heating and cooling thermal performance of a CO2 heat pump system considering the sub-cooling effect. For such a system without cold thermal energy storage (CTES), the gas cooler outlet temperature normally needs to be controlled to match the cooling load required. However, the integration of CTES would enable the system to be operated under its optimal conditions depending on the ambient temperatures, i.e. a considerable amount of cooling capac-ity can be generated and stored for later use. A configuration of a CO(2 )heat pump integrated with CTES is described in this paper. A thermodynamic cycle and a simulation model considering the subcooling effect have been developed. The math-ematical model for the pinch point analysis has been newly validated against published experimental data with acceptable agreements. In the case study, the impacts of the subcooling temperature on the optimal combined performance under four ambient temperatures (5 degrees C, 15 degrees C, 25 degrees C, and 32 degrees C) have been studied. The highest optimal combined COP of 5.38 can be achieved when the ambient temperature is 5 degrees C. The detailed profiles of CO2 temperatures, heating and cooling loads, and the COPs when the CTES is in operation have been revealed for the first time. It is found when the ambient temperature is higher than the water inlet temperature (plus the pinch point temperature), the optimal cooling COPs can even have a surge without the subcooling effect, due to a lower sCO(2) temperature leaving the heat exchanger compared to the ambient temperature. Additionally, performance analysis for the CO2 heat pump system with or without CTES is compared, and it is concluded that all optimal heating, cooling, and combined COPs integrated with CTES surpass those without CTES.
引用
收藏
页码:1257 / 1275
页数:19
相关论文
共 40 条
  • [1] [Anonymous], SWEP HEAT EXCHANGER
  • [2] A criterion for predicting the possible advantage of adopting a suction/liquid heat exchanger in refrigerating system
    Aprea, C
    Ascani, M
    de Rossi, F
    [J]. APPLIED THERMAL ENGINEERING, 1999, 19 (04) : 329 - 336
  • [3] Experimental analysis of energy performance of modified single-stage CO2 transcritical vapour compression cycles based on vapour injection in the suction line
    Cabello, Ramon
    Sanchez, Daniel
    Patino, Jorge
    Llopis, Rodrigo
    Torrella, Enrique
    [J]. APPLIED THERMAL ENGINEERING, 2012, 47 : 86 - 94
  • [4] Two-stage transcritical carbon dioxide cycle optimisation: A theoretical and experimental analysis
    Cavallini, A
    Cecchinato, L
    Corradi, M
    Fornasieri, E
    Zilio, C
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08): : 1274 - 1283
  • [5] Thermodynamic analysis of different two-stage transcritical carbon dioxide cycles
    Cecchinato, Luca
    Chiarello, Manuel
    Corradi, Marco
    Fornasieri, Ezio
    Minetto, Silvia
    Stringari, Paolo
    Zilio, Claudio
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (05): : 1058 - 1067
  • [6] Optimal heat rejection pressure of CO2 heat pump water heaters based on pinch point analysis
    Chen, Yun-Guang
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 : 592 - 603
  • [7] Performance evaluation of a two-stage CO2 cycle with gas injection in the cooling mode operation
    Cho, Honghyun
    Baek, Changhyun
    Park, Chasik
    Kim, Yongchan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (01): : 40 - 46
  • [8] Advances in heat pump systems: A review
    Chua, K. J.
    Chou, S. K.
    Yang, W. M.
    [J]. APPLIED ENERGY, 2010, 87 (12) : 3611 - 3624
  • [9] Czaplicka N, 2021, INT J MOL SCI, V22
  • [10] EVALUATION OF SUCTION-LINE LIQUID-LINE HEAT-EXCHANGE IN THE REFRIGERATION CYCLE
    DOMANSKI, PA
    DIDION, DA
    DOYLE, JP
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1994, 17 (07): : 487 - 493