A high risk of postoperative periprosthetic femoral fracture in Dorr type C femurs: a retrospective cohort study with 10-year follow-up data and a preliminary monochromatic image analysis

被引:2
作者
Li, Mingyang [1 ,2 ]
Zeng, Yi [1 ,2 ]
Nie, Yong [1 ,2 ]
Liao, Kai [3 ]
Pei, Fuxing [1 ,2 ]
Yang, Jing [1 ,2 ]
Xie, Huiqi [1 ,2 ]
Shen, Bin [1 ,2 ,4 ]
机构
[1] West China Hosp, Dept Orthoped Surg, Chengdu, Peoples R China
[2] West China Hosp, Orthoped Res Inst, Chengdu, Peoples R China
[3] Sichuan Univ, West China Hosp, West China Med Sch, Dept Radiol, Chengdu, Sichuan, Peoples R China
[4] Sichuan Univ, West China Hosp, Orthoped Res Inst, Dept Orthopaed, 37 Guoxue Rd, Chengdu 610041, Peoples R China
关键词
bone growth; Dorr type C femurs; short stems; spectral CT; TOTAL HIP-ARTHROPLASTY; STEM; COMPONENT; FIXATION; REPLACEMENT; PROSTHESES; IMPLANTS; SURVIVAL; CEMENT; FIT;
D O I
10.1097/JS9.0000000000000810
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The authors applied Anatomique Benoist Girard II (ABG II) stems for total hip arthroplasty in some Dorr type C femurs as early attempts. Here, the authors compared the long-term follow-up results between ABG II stems and the Modified Letter Turned Commawell-performing' Corail stems and their monochromatic images.Methods: Among 3214 primary total hip arthroplasty records, 43 short ABG II stems and 67 standard-length Corail stems implanted in Dorr type C femurs were eligible and enrolled in this retrospective cohort study, with a mean follow-up of 10.3 years. Revision rates, Harris hip scores, and radiologic signs were compared. Spectral CT scans from a representative sample were obtained, and monochromatic images were reconstructed. A quantitative method was developed to measure the volume of the gap around stems. Patient-specific finite element analysis was conducted to investigate the strains.Results: The revision rate of ABG II stems was significantly higher than that of Corail stems (21 vs. 3%, P<0.05). In the monochromatic images, fewer spot-weld signs (2.2 vs. 3.4, P<0.05) and wider gaps around stems (1.64 cm(3) vs. 0.13 cm(3), P<0.05) were observed on average in the ABG II group. The mean maximum principal strains of the proximal femurs in the ABG II group were close to the yield strains and significantly larger than those in the Corail group (0.0052 vs. 0.0011, P<0.05).Conclusions: There was a high risk of postoperative periprosthetic femoral fracture for ABG II stems in Dorr type C femurs. Monochromatic images provided some insight into the failure mechanism.Level of Evidence: III
引用
收藏
页码:296 / 305
页数:10
相关论文
共 55 条
[1]  
Hatem Munif Ahmad, 2014, Rev. bras. ortop., V49, P260, DOI 10.1016/j.rboe.2014.02.007
[2]   Good stability of a cementless, anatomically designed femoral stem in aging women: a 9-year RSA study of 32 patients [J].
Aro, Erik ;
Alm, Jessica J. ;
Moritz, Niko ;
Mattila, Kimmo ;
Aro, Hannu T. .
ACTA ORTHOPAEDICA, 2018, 89 (05) :490-495
[3]   Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue [J].
Bayraktar, HH ;
Morgan, EF ;
Niebur, GL ;
Morris, GE ;
Wong, EK ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :27-35
[4]   The effect of muscle loading on the simulation of bone remodelling in the proximal femur [J].
Bitsakos, C ;
Kerner, J ;
Fisher, I ;
Amis, AA .
JOURNAL OF BIOMECHANICS, 2005, 38 (01) :133-139
[5]   Proximally Coated Cementless Bipolar Hemiarthroplasty in Dorr Type C Bone [J].
Bonutti, Peter M. ;
Stroh, Alex D. ;
Issa, Kimona ;
Harwin, Steven F. ;
Patel, Dipak V. ;
Mont, Michael A. .
ORTHOPEDICS, 2014, 37 (04) :E345-E350
[6]   Bone Remodeling Characteristics of a Short-Stemmed Total Hip Replacement [J].
Chen, Hsiang-Ho ;
Morrey, Bernard F. ;
An, Kai-Nan ;
Luo, Zong-Ping .
JOURNAL OF ARTHROPLASTY, 2009, 24 (06) :945-950
[7]  
Chow S.C., 2017, Sample size calculations in clinical research, V3rd ed.
[8]  
Christie M, 2005, ORTHOPEDICS, V28, pS1033
[9]   THE EFFECT OF OPERATIVE FIT AND HYDROXYAPATITE COATING ON THE MECHANICAL AND BIOLOGICAL RESPONSE TO POROUS IMPLANTS [J].
DALTON, JE ;
COOK, SD ;
THOMAS, KA ;
KAY, JF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (01) :97-110
[10]   Modern Proximally Tapered Uncemented Stems Can Be Safely Used in Dorr Type C Femoral Bone [J].
Dalury, David F. ;
Kelley, Todd C. ;
Adams, Mary Jo .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :1014-1018