Influence of the background in Compton camera images for proton therapy treatment monitoring

被引:3
作者
Borja-Lloret, M. [1 ]
Barrientos, L. [1 ]
Bernabeu, J. [1 ]
Lacasta, C. [1 ]
Munoz, E. [1 ]
Ros, A. [1 ]
Roser, J. [1 ]
Viegas, R. [1 ]
Llosa, G. [1 ]
机构
[1] Inst Fis Corpuscular IFIC, CSIC UV, Valencia, Spain
关键词
Compton imaging; Compton camera; proton therapy; treatment monitoring; Monte Carlo simulation; image reconstruction; background; VIVO RANGE VERIFICATION; PROMPT-GAMMA EMISSION; MONTE-CARLO; 1ST TEST; SIMULATION; PERFORMANCE; TELESCOPE; TOOLKIT; ENERGY;
D O I
10.1088/1361-6560/ace024
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Background events are one of the most relevant contributions to image degradation in Compton camera imaging for hadron therapy treatment monitoring. A study of the background and its contribution to image degradation is important to define future strategies to reduce the background in the system. Approach. In this simulation study, the percentage of different kinds of events and their contribution to the reconstructed image in a two-layer Compton camera have been evaluated. To this end, GATE v8.2 simulations of a proton beam impinging on a PMMA phantom have been carried out, for different proton beam energies and at different beam intensities. Main results. For a simulated Compton camera made of Lanthanum (III) Bromide monolithic crystals, coincidences caused by neutrons arriving from the phantom are the most common type of background produced by secondary radiations in the Compton camera, causing between 13% and 33% of the detected coincidences, depending on the beam energy. Results also show that random coincidences are a significant cause of image degradation at high beam intensities, and their influence in the reconstructed images is studied for values of the time coincidence windows from 500 ps to 100 ns. Significance. Results indicate the timing capabilities required to retrieve the fall-off position with good precision. Still, the noise observed in the image when no randoms are considered make us consider further background rejection methods.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Influence of Doppler broadening model accuracy in Compton camera list-mode MLEM reconstruction
    Feng, Yuemeng
    Letang, Jean Michel
    Sarrut, David
    Maxim, Voichia
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2021, 29 (13) : 3509 - 3529
  • [42] Experimental study on Compton camera for boron neutron capture therapy applications
    Sakai, M.
    Tamaki, S.
    Murata, I.
    Parajul, R. K.
    Matsumura, A.
    Kubo, N.
    Tashiro, M.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [43] Towards offline PET monitoring of proton therapy at MedAustron
    Meissner, Heide
    Fuchs, Hermann
    Hirtl, Albert
    Reschl, Christian
    Stock, Markus
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (01): : 59 - 65
  • [44] First demonstration of real-time gamma imaging by using a handheld Compton camera for particle therapy
    Taya, T.
    Kataoka, J.
    Kishimoto, A.
    Iwamoto, Y.
    Koide, A.
    Nishio, T.
    Kabuki, S.
    Inaniwa, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 831 : 355 - 361
  • [45] Estimating influence of positron range in proton-therapy-beam monitoring with PET
    Mryka, Wiktor
    Das, Manish
    Beyene, Ermias Y.
    Moskal, Pawei
    Stgpieri, Ewa
    BIO-ALGORITHMS AND MED-SYSTEMS, 2023, 19 (01) : 96 - 100
  • [46] Fast calculation of nanodosimetric quantities in treatment planning of proton and ion therapy
    Ramos-Mendez, Jose
    Burigo, Lucas N.
    Schulte, Reinhard
    Chuang, Cynthia
    Faddegon, Bruce
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23)
  • [47] 'Accurate proton range shift verification by using a two-layer dense-pixel LYSO compton camera prototype
    Dong, Minghao
    Yao, Zhiyang
    Xiao, Yongshun
    Bi, Chongbo
    Li, Wenliang
    Du, Changtong
    Zhang, Huayi
    Hu, Chuang
    Fan, Yongshan
    Xing, Qingzi
    Wang, Xuewu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1063
  • [48] Measuring Prompt Gamma Emission Profiles with a Multi-Stage Compton Camera During Proton Beam Irradiaition: Initial Studies
    Polf, J.
    Brown, S.
    Mann, J.
    Mackin, D.
    Zheng, Y.
    McCleskey, M.
    Beddar, S.
    He, Z.
    MEDICAL PHYSICS, 2014, 41 (06) : 183 - 183
  • [49] Capability of MLEM and OE to Detect Range Shifts With a Compton Camera in Particle Therapy
    Kohlhase, Nadja
    Wegener, Tilman
    Schaar, Moritz
    Bolke, Andreas
    Etxebeste, Ane
    Sarrut, David
    Rafecas, Magdalena
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (02) : 233 - 242
  • [50] Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy
    Mackin, Dennis
    Peterson, Steve
    Beddar, Sam
    Polf, Jerimy
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11) : 3537 - 3553