Velocity vector comparison between vector flow imaging and computational fluid dynamics in the carotid bifurcation

被引:5
|
作者
Poloni, Sofia [1 ]
Bozzetto, Michela [1 ]
Du, Yigang
Aiani, Luca [2 ]
Goddi, Alfredo [2 ]
Fiorina, Ilaria [3 ]
Remuzzi, Andrea [4 ,5 ,6 ]
机构
[1] Ist Ric Farmacol Mario Negri IRCCS, Dept Biomed Engn, Bergamo, Italy
[2] Shenzhen Mindray Biomed Elect Co Ltd, Shenzhen 518057, Peoples R China
[3] Ctr Med SME Diagnost Immagini, Varese, Italy
[4] Fdn IRCCS Policlin San Matteo, Inst Radiol, Pavia, Italy
[5] Univ Bergamo, Dept Management Informat & Prod Engn, Dalmine, Italy
[6] Univ Bergamo, Via Marconi, Dalmine, Italy
关键词
Carotid artery; HiFR-VFI; CFD; Velocity vectors; Blood velocity validation; ULTRASOUND; STENOSIS; ARTERY;
D O I
10.1016/j.ultras.2022.106860
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
It has been largely documented that local hemodynamic conditions, characterized by low and oscillating wall shear stresses, play a key role in the initiation and progression of vascular atherosclerotic lesions. Thus, investigation of the flow field in the carotid bifurcation can lead to early identification of vulnerable plaques. In this scenario, the development of novel non-invasive imaging tools that can be used in routine clinical practice to identify disturbed and recirculating blood flow becomes crucial. In this context, Vector Flow Imaging is becoming a relevant tool as it provides an angle independent assessment of blood flow velocity and multidimensional flow vector visualization. The purpose of the present study was to validate, in several locations of the carotid bifurcation, the high-frame rate vector flow imaging (HiFR-VFI) technique by comparing with computational fluid dynamic simulations (CFD).In all eight carotid bifurcations, HiFR-VFI accurately detected regions of laminar flow as well as recirculation and unsteady flow areas. An accurate and statistically significant agreement was observed between velocity vectors obtained by HiFR-VFI and those computed by CFD, both for vector magnitude (R = 0.85) and direction (R = 0.74).Our study demonstrated that HiFR-VFI is a valid technique for rapid and advanced visual representation of velocity field in large arteries. Thus, it has a great potential in research-based clinical practice for the identification of flow recirculation, low and oscillating velocity gradients near vessel wall. The use of HiFR-VFI may provide a great improvement in the investigation of the role of local hemodynamics in vascular pathologies, as well in the assessment of the effect of pharmacological treatments.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A perspective review: Technical study of combining phase contrast magnetic Resonance imaging and computational fluid dynamics for blood flow on carotid bifurcation artery
    Adib, Mohd Azrul Hisham Mohd
    Hong, Lim Sheh
    Abdullah, Mohd Shafie
    Hassan, Radhiana
    Abd Aziz, Azian
    Wada, Shigeo
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2020, 14 (04) : 7609 - 7621
  • [32] A COMPARISON STUDY OF VECTOR VELOCITY, SPECTRAL DOPPLER AND MAGNETIC RESONANCE OF BLOOD FLOW IN THE COMMON CAROTID ARTERY
    Brandt, Andreas Hjelm
    Hansen, Kristoffer Lindskov
    Ewertsen, Caroline
    Holbek, Simon
    Olesen, Jacob Bjerring
    Moshavegh, Ramin
    Thomsen, Carsten
    Jensen, Jorgen Arendt
    Nielsen, Michael Bachmann
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (08): : 1751 - 1761
  • [33] Reproducibility Study of Magnetic Resonance Image-Based Computational Fluid Dynamics Prediction of Carotid Bifurcation Flow
    F. P. Glor
    Q. Long
    A. D. Hughes
    A. D. Augst
    B. Ariff
    S. A. McG. Thom
    P. R. Verdonck
    X. Y. Xu
    Annals of Biomedical Engineering, 2003, 31 : 142 - 151
  • [34] Reproducibility study of magnetic resonance image-based computational fluid dynamics prediction of carotid bifurcation flow
    Glor, FP
    Long, Q
    Hughes, AD
    Augst, AD
    Ariff, B
    Thom, SAM
    Verdonck, PR
    Xu, XY
    ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (02) : 142 - 151
  • [35] Velocity Vector Imaging in the Measurement of Left Ventricular Twist Mechanics: Head-to-Head One Way Comparison Between Speckle Tracking Echocardiography and Velocity Vector Imaging
    Kim, Dae-Hee
    Kim, Hyung-Kwan
    Kim, Min-Kyung
    Chang, Sung-A
    Kim, Yong-Jin
    Kim, Myung-A
    Sohn, Dae-Won
    Oh, Byung-Hee
    Park, Young-Bae
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (12) : 1344 - 1352
  • [36] Examples of Vector Velocity Imaging
    Hansen, Peter M.
    Pedersen, Mads M.
    Hansen, Kristoffer L.
    Nielsen, Michael B.
    Jensen, Jorgen A.
    15TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS (NBC 2011), 2011, 34 : 77 - +
  • [37] Doppler beam steering for blood flow velocity vector imaging
    He, SP
    Dajani, KF
    Lu, JY
    ACOUSTICAL IMAGING, VOL 25, 2000, 25 : 443 - 448
  • [38] A Comparison Between Compounding Techniques Using Large Beam-Steered Plane Wave Imaging for Blood Vector Velocity Imaging in a Carotid Artery Model
    Saris, Anne E. C. M.
    Hansen, Hendrik H. G.
    Fekkes, Stein
    Nillesen, Maartje M.
    Rutten, Marcel C. M.
    de Korte, Chris L.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (11) : 1758 - 1771
  • [39] MEASUREMENT OF FLOW VELOCITY IN THE CAROTID BIFURCATION MODELS USING MULTI-ANGLE COMPOUND CROSS-BEAM VECTOR DOPPLER
    Wang, Kang-yu
    Zhou, Yu-liu
    He, Li-yuan
    Lu, Chun-yao
    Yu, Run
    Wu, Da-wei
    PROCEEDINGS OF THE 2020 15TH SYMPOSIUM ON PIEZOELECTRCITY, ACOUSTIC WAVES AND DEVICE APPLICATIONS (SPAWDA), 2021, : 156 - 159
  • [40] Coronary artery bifurcation haemodynamics - comparison between phase contrast MRI and computational fluid dynamics
    Susann Beier
    John Ormiston
    Mark Webster
    John Cater
    Pau Medrano-Gracia
    Alistair Young
    Brett R Cowan
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)