Velocity vector comparison between vector flow imaging and computational fluid dynamics in the carotid bifurcation

被引:5
|
作者
Poloni, Sofia [1 ]
Bozzetto, Michela [1 ]
Du, Yigang
Aiani, Luca [2 ]
Goddi, Alfredo [2 ]
Fiorina, Ilaria [3 ]
Remuzzi, Andrea [4 ,5 ,6 ]
机构
[1] Ist Ric Farmacol Mario Negri IRCCS, Dept Biomed Engn, Bergamo, Italy
[2] Shenzhen Mindray Biomed Elect Co Ltd, Shenzhen 518057, Peoples R China
[3] Ctr Med SME Diagnost Immagini, Varese, Italy
[4] Fdn IRCCS Policlin San Matteo, Inst Radiol, Pavia, Italy
[5] Univ Bergamo, Dept Management Informat & Prod Engn, Dalmine, Italy
[6] Univ Bergamo, Via Marconi, Dalmine, Italy
关键词
Carotid artery; HiFR-VFI; CFD; Velocity vectors; Blood velocity validation; ULTRASOUND; STENOSIS; ARTERY;
D O I
10.1016/j.ultras.2022.106860
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
It has been largely documented that local hemodynamic conditions, characterized by low and oscillating wall shear stresses, play a key role in the initiation and progression of vascular atherosclerotic lesions. Thus, investigation of the flow field in the carotid bifurcation can lead to early identification of vulnerable plaques. In this scenario, the development of novel non-invasive imaging tools that can be used in routine clinical practice to identify disturbed and recirculating blood flow becomes crucial. In this context, Vector Flow Imaging is becoming a relevant tool as it provides an angle independent assessment of blood flow velocity and multidimensional flow vector visualization. The purpose of the present study was to validate, in several locations of the carotid bifurcation, the high-frame rate vector flow imaging (HiFR-VFI) technique by comparing with computational fluid dynamic simulations (CFD).In all eight carotid bifurcations, HiFR-VFI accurately detected regions of laminar flow as well as recirculation and unsteady flow areas. An accurate and statistically significant agreement was observed between velocity vectors obtained by HiFR-VFI and those computed by CFD, both for vector magnitude (R = 0.85) and direction (R = 0.74).Our study demonstrated that HiFR-VFI is a valid technique for rapid and advanced visual representation of velocity field in large arteries. Thus, it has a great potential in research-based clinical practice for the identification of flow recirculation, low and oscillating velocity gradients near vessel wall. The use of HiFR-VFI may provide a great improvement in the investigation of the role of local hemodynamics in vascular pathologies, as well in the assessment of the effect of pharmacological treatments.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Characteristics and Correlations of Wall Shear Stress and Flow Turbulence in the Carotid Bifurcation Evaluated Using an Ultrasound Vector Flow Imaging
    Liu, Mengmeng
    Song, Di
    Hong, Shaofu
    Dong, Yinghui
    Gao, Wenjing
    Du, Yigang
    Zhu, Lei
    Xu, Jinfeng
    Dong, Fajin
    JOURNAL OF VASCULAR RESEARCH, 2024, 61 (01) : 38 - 49
  • [22] Comparative study of magnetic resonance imaging and image-based computational fluid dynamics for quantification of pulsatile flow in a carotid bifurcation phantom
    Zhao, SZ
    Papathanasopoulou, P
    Long, Q
    Marshall, I
    Xu, XY
    ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (08) : 962 - 971
  • [23] Recent Advances in Blood Flow Vector Velocity Imaging
    Jensen, Jorgen Arendt
    Nikolov, Svetoslav Ivanov
    Udesen, Jesper
    Munk, Peter
    Hansen, Kristoffer Lindskov
    Pedersen, Mads Moller
    Hansen, Peter Moller
    Nielsen, Michael Bachmann
    Oddershede, Niels
    Kortbek, Jacob
    Pihl, Michael Johannes
    Li, Ye
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 262 - 271
  • [24] Comparative Study of Magnetic Resonance Imaging and Image-Based Computational Fluid Dynamics for Quantification of Pulsatile Flow in a Carotid Bifurcation Phantom
    S. Z. Zhao
    P. Papathanasopoulou
    Q. Long
    I. Marshall
    X. Y. Xu
    Annals of Biomedical Engineering, 2003, 31 : 962 - 971
  • [25] Comparison of Blood Flow Velocity Quantification by 4D Flow MR Imaging with Ultrasound at the Carotid Bifurcation
    Harloff, A.
    Zech, T.
    Wegent, F.
    Strecker, C.
    Weiller, C.
    Markl, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (07) : 1407 - 1413
  • [26] Velocity Measurement at Carotid Siphon: Quantitative Comparison of Phase Contrast MRI and Computational Fluid Dynamics
    Zhang, Chi
    Yang, Jinfeng
    Ding, Ning
    Chang, Feiyan
    Xie, Sheng
    Li, Deyu
    Hou, Xiaoxu
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 499 - 504
  • [27] NUMERICAL ALGORITHMS IN COMPUTATIONAL FLUID-DYNAMICS ON VECTOR COMPUTERS
    GENTZSCH, W
    PARALLEL COMPUTING, 1984, 1 (01) : 19 - 33
  • [28] NUMERICAL ALGORITHMS IN COMPUTATIONAL FLUID DYNAMICS ON VECTOR COMPUTERS.
    Gentzsch, Wolfgang
    1600, (01):
  • [29] Precise evaluation of blood flow patterns in human carotid bifurcation based on high-frame-rate vector flow imaging
    Hong, Shaofu
    Dong, Yinghui
    Song, Di
    Liu, Mengmeng
    Gao, Wenjing
    Li, Weiyue
    Wan, Yong
    Du, Yigang
    Xu, Jinfeng
    Dong, Fajin
    JOURNAL OF CLINICAL ULTRASOUND, 2023, 51 (06) : 1070 - 1077
  • [30] Flow Velocity Vector Fields by Ultrasound Particle Imaging Velocimetry In Vitro Comparison With Optical Flow Velocimetry
    Westerdale, John
    Belohlavek, Marek
    McMahon, Eileen M.
    Jiamsripong, Panupong
    Heys, Jeffrey J.
    Milano, Michele