Incorporation of phase change materials in fire protective clothing considering the presence of water

被引:15
作者
Malaquias, Andre Fonseca [1 ,2 ,3 ]
Neves, S. F. [1 ,2 ]
Campos, J. B. L. M. [1 ,2 ]
机构
[1] Univ Porto, Fac Engn, Transport Phenomena Res Ctr, CEFT, Rua Dr, P-4200465 Porto, Portugal
[2] Univ Porto, Fac Engn, ALiCE Associate Lab Chem Engn, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
[3] Univ Porto, Fac Engn, Transport Phenomena Res Ctr, CEFT, Rua Dr, P-4200465 Porto, Portugal
关键词
Firefighting garment; Numerical simulation; Steam burns; Second-degree burns; Phase change materials; Initial water content; MOISTURE TRANSFER; STEAM FORMATION; HEAT-TRANSFER; HUMAN-BODY; PERFORMANCE; TEXTILES; FABRICS; MODEL;
D O I
10.1016/j.ijthermalsci.2022.107870
中图分类号
O414.1 [热力学];
学科分类号
摘要
When firefighters face a heat exposure, free water may be present in the fire protective clothing (FPC). Recently, the incorporation of Phase Change Materials (PCMs) into FPC has shown great promise to increase thermal performance when in the dry state. However, the presence of water in firefighting garments is expected and how this alters the thermal behavior of a PCM FPC assembly still remains to be discussed in the literature. Hence, this study concerns the effect of free water presence in the outer shell and/or thermal inner of a PCM FPC assembly consisting of 3 layers. A new mathematical model is proposed where the PCM is assumed to be incorporated in the thermal inner. A numerical analysis is performed where PCM textile latent heat, water distribution, and heat flux intensity are varied. Skin temperature, skin heat flux, and PCM liquid fraction profiles are obtained along with second-degree burn times to measure thermal performance. It is found that steam condensation at the skin reduces PCM liquid fraction at second-degree burn time, when compared to the dry case. This study tends to shine a light on the importance of considering moisture management in PCM FPC assemblies so as to promote maximum PCM efficiency.
引用
收藏
页数:14
相关论文
共 46 条
  • [1] Effects of moisture on the thermal protective performance of firefighter protective clothing in low-level radiant heat exposures
    Barker, RL
    Guerth-Schacher, C
    Grimes, RV
    Hamouda, H
    [J]. TEXTILE RESEARCH JOURNAL, 2006, 76 (01) : 27 - 31
  • [2] Bendkowska W, 2009, FIBRES TEXT EAST EUR, V17, P87
  • [3] A geometrically accurate 3 dimensional model of human thermoregulation for transient cold and hot environments
    Castellani, Michael P.
    Rioux, Timothy P.
    Castellani, John W.
    Potter, Adam W.
    Xu, Xiaojiang
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 138
  • [4] Chitrphiromsri P., 2004, MODELING THERMAL PER
  • [5] Evaluation of Functionality of Warning System in Smart Protective Clothing for Firefighters
    Dabrowska, Anna
    Bartkowiak, Grazyna
    Kotas, Rafal
    [J]. SENSORS, 2021, 21 (05) : 1 - 14
  • [6] Donnelly M.K., 2006, Natl. Inst. Stand. Technol. Spec. Publ, V1474, P41
  • [7] DuPont, 2001, Technical Guide for NOMEX Brand Fiber
  • [8] A transient three-dimensional heat transfer model of the human body
    Ferreira, M. S.
    Yanagihara, J. I.
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (07) : 718 - 724
  • [9] Thermal performance of a PCM firefighting suit considering transient periods of fire exposure, post - fire exposure and resting phases
    Fonseca, A.
    Neves, S. F.
    Campos, J. B. L. M.
    [J]. APPLIED THERMAL ENGINEERING, 2021, 182
  • [10] Guidelines for the specification of a PCM layer in firefighting protective clothing ensembles
    Fonseca, A.
    Mayor, T. S.
    Campos, J. B. L. M.
    [J]. APPLIED THERMAL ENGINEERING, 2018, 133 : 81 - 96