Possibilities and limits of intraoperative 2D imaging in trauma surgery

被引:0
|
作者
Watrinet, Julius [1 ]
Wenzel, Lisa [1 ]
Fuermetz, Julian [1 ]
Augat, Peter [2 ,3 ]
Blum, Philipp [1 ]
Neidlein, Claas [4 ]
Bormann, Markus [4 ]
Stuby, Fabian [1 ]
von Rueden, Christian [2 ,5 ]
机构
[1] BG Unfallklin Murnau, Abt Unfallchirurg, Murnau, Germany
[2] Paracelsus Med Privatuniv, Univ Inst Biomech, Salzburg, Austria
[3] BG Unfallklin Murnau, Inst Biomech, Murnau, Germany
[4] Ludwig Maximilians Univ Munchen LMU, Muskuloskelettales Univ Zentrum Munchen, Munich, Germany
[5] Klinikum Weiden, Klin Unfallchirurg Orthopadie & Handchirurg, Weiden, Germany
来源
UNFALLCHIRURGIE | 2023年 / 26卷 / 12期
关键词
Fluoroscopy; Computed tomography; Image quality; Bone fractures; Fracture reduction; FRACTURES; ACCURACY; INJURY;
D O I
10.1007/s00113-023-01381-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The two-dimensional (2D) imaging represents an essential and cost-effective component of intraoperative position control in fracture stabilization, even in the era of new three-dimensional (3D) imaging capabilities. Objective: The aim of the present study, in addition to a current literature review, was to examine whether the intraoperative use of 2D images leads to a quality of fracture reduction comparable to postoperative computed tomographic (CT) analysis including 3D reconstructions. Material and methods: A comparative retrospective analysis of intraoperative 2D and postoperative 3D image data was performed on 21 acetabular fractures stabilized via a pararectus approach according to an established protocol using the Matta criteria. Results: The assessment of fracture reduction in intraoperative fluoroscopy compared with postoperative CT revealed a difference only in one case with respect to the categorization of the joint step reduction in the main loading zone. Conclusion: In the intraoperative use of 2D imaging for fracture treatment it is important to select the correct adjustment planes taking the anatomical conditions into account in order to achieve optimum assessability. In this way, the reduction result can be adequately displayed in fluoroscopy and is also comparable to the postoperative CT control. In addition, depending on the findings, optional intraoperative dynamic fluoroscopic assessment can have a direct influence on the further surgical procedure.
引用
收藏
页码:935 / 941
页数:7
相关论文
共 50 条
  • [1] Möglichkeiten und Grenzen der intraoperativen 2D-Bildgebung in der UnfallchirurgiePossibilities and limits of intraoperative 2D imaging in trauma surgery
    Julius Watrinet
    Lisa Wenzel
    Julian Fürmetz
    Peter Augat
    Philipp Blum
    Claas Neidlein
    Markus Bormann
    Fabian Stuby
    Christian von Rüden
    Die Unfallchirurgie, 2023, 126 (12) : 935 - 941
  • [2] Role of 3D intraoperative imaging in orthopedic and trauma surgery
    Tonetti, Jerome
    Boudissa, Mehdi
    Kerschbaumer, Gael
    Seurat, Olivier
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (01) : S19 - S25
  • [3] Intraoperative 3D-RX imaging of the extremities for trauma surgery
    Haverlag, R.
    Carelsen, B.
    Streekstra, G. J.
    van Kemenade, P.
    Goslings, J. C.
    PROCEEDINGS OF THE 7TH EUROPEAN TRAUMA CONGRESS, 2006, : 405 - +
  • [4] EVALUATING THE EFFECTIVENESS OF NONNAVIGATED 2D INTRAOPERATIVE ULTRASOUND IN GLIOMA SURGERY: RECONSIDERING THE PUSH FOR MORE COMPLEX INTRAOPERATIVE IMAGING
    Cepeda, Santiago
    Garcia-Garcia, Sergio
    Arrese, Ignacio
    Sarabia, Rosario
    NEURO-ONCOLOGY, 2023, 25
  • [5] Development of intraoperative C-arm imaging in trauma surgery
    Krettek, C.
    Gebhard, F.
    UNFALLCHIRURG, 2012, 115 (02): : 100 - 106
  • [6] POSSIBILITIES AND LIMITS OF PANCREATIC SURGERY
    NEHER, M
    MANGOLD, G
    RUCKERT, K
    KUMMERLE, F
    MEDIZINISCHE KLINIK, 1980, 75 (17) : 23 - 27
  • [7] Intraoperative 3D imaging in spinal surgery
    Gonschorek, O.
    Hauck, S.
    Buehren, V.
    UNFALLCHIRURG, 2016, 119 (10): : 817 - 824
  • [8] Limits and possibilities of 2D video analysis in valuating physiological and pathological support phases of the food in runners
    Grau, S
    Müller, O
    Bäurle, W
    Beck, M
    Krauss, I
    Maiwald, C
    Baur, H
    Mayer, F
    SPORTVERLETZUNG-SPORTSCHADEN, 2000, 14 (03) : 107 - 114
  • [10] QUALITY ASSURANCE IN SURGERY - POSSIBILITIES AND LIMITS
    PICHLMAIER, H
    GRUNDMANN, R
    ZENTRALBLATT FUR CHIRURGIE, 1987, 112 (17): : 1092 - 1098