Count rate correction for pulse pileup in CdZnTe photon counting detectors

被引:0
|
作者
Kang, Yang [1 ,2 ]
Wu, Rui [1 ,2 ]
Li, Peizheng [1 ,2 ]
Li, Qingpei [1 ,2 ]
Yin, Ziang [1 ,2 ]
Wu, Sen [1 ,2 ]
Tan, Tingting [1 ,2 ]
Li, Yingrui [1 ,2 ,3 ]
Zha, Gangqiang [1 ,2 ,3 ]
机构
[1] Northwestern Polytech Univ, State Key Lab Solidificat Proc, Xian 710072, Peoples R China
[2] Northwestern Polytech Univ, MIIT Key Lab Radiat Detect Mat & Devices, Xian 710072, Peoples R China
[3] Northwestern Polytech Univ, MIIT Key Lab Radiat Detect Mat & Devices, Xian 710072, Peoples R China
关键词
Photon counting; Pulse pileup; CdZnTe detector; Count rate correction; X-RAY; CDTE;
D O I
10.1016/j.mssp.2024.108142
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the practical application of CdZnTe photon counting detectors, severe detector counting distortion can be caused by pulse pileup. A count rate correction method in this paper is proposed to solve this problem. In this method, the case where multi -photons are recorded by higher energy regions due to pulse pileup crossing the energy threshold is considered to calculate the true count rates under all energy bins. A verification method based on Poisson distribution is also proposed to evaluate the accuracy of the correction method. A 16 -pixel linear array CdZnTe photon counting detector was used for verification. Taking the dual -energy bin as an example, this method was introduced, and the true count rates of the high- and low -energy bins are successfully calculated. The result was highly consistent with the verification result, which proves the reliability of the proposed method.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Experimental study of photon-counting CT neural network material decomposition under conditions of pulse pileup
    Jenkins, Parker J. B.
    Schmidt, Taly Gilat
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (01)
  • [22] Improving pulse detection in multibin photon-counting detectors
    Hsieh, Scott S.
    Pelc, Norbert J.
    JOURNAL OF MEDICAL IMAGING, 2016, 3 (02)
  • [23] Modeling photon-counting detectors for x-ray CT: spectral response and pulse-pileup effects and evaluation using real data
    Cammin, J.
    Xu, J.
    Barber, W. C.
    Iwanczyk, J. S.
    Hartsough, N. E.
    Taguchi, K.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [24] A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT
    Cammin, Jochen
    Xu, Jennifer
    Barber, William C.
    Iwanczyk, Jan S.
    Hartsough, Neal E.
    Taguchi, Katsuyuki
    MEDICAL PHYSICS, 2014, 41 (04)
  • [25] Pulse Temporal Splitting in Photon Counting X-Ray Detectors
    Engel, Klaus Jurgen
    Steadman, Roger
    Herrmann, Christoph
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (04) : 1480 - 1490
  • [26] Exploration of the pulse pileup effects in a clinical CdTe-based photon-counting computed tomography
    Bhattarai, Mridul
    Bache, Steve
    Abadi, Ehsan
    Samei, Ehsan
    MEDICAL PHYSICS, 2023, 50 (11) : 6693 - 6703
  • [27] Non-uniformity correction for MARS photon-counting detectors
    Getzin, Matthew
    Li, Mengzhou
    Rundle, David S.
    Butler, Anthony P.
    Wang, Ge
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [28] Assessment of multi-energy inter-pixel coincidence counters for photon-counting detectors at the presence of charge sharing and pulse pileup: A simulation study
    Taguchi, Katsuyuki
    Iwanczyk, Jan S.
    MEDICAL PHYSICS, 2021, 48 (09) : 4909 - 4925
  • [29] Pulse detection logic for multibin photon counting detectors: beyond the simple comparator
    Hsieh, Scott S.
    Pelc, Norbert J.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [30] Dead-time correction for spectroscopic photon-counting pixel detectors
    Blaj, Gabriel