Performance of Cryptococcal Antigen Lateral Flow Assay in Bronchoalveolar Lavage Fluid in HIV-Negative Patients

被引:0
|
作者
Yang, Jing [1 ,3 ]
Chen, Lei [1 ]
Qiu, Feng [1 ]
Liu, Yanqing [2 ]
Hu, Liqing [2 ]
机构
[1] Ningbo Univ, Affiliated Hosp 1, Dept Resp & Crit Care Med, Ningbo, Zhejiang, Peoples R China
[2] Ningbo Univ, Affiliated Hosp 1, Dept Lab Med, Ningbo, Zhejiang, Peoples R China
[3] Ningbo Univ, Affiliated Hosp 1, Dept Resp & Crit Care Med, Liuting St 59, Ningbo 315010, Zhejiang, Peoples R China
来源
ANNALS OF CLINICAL AND LABORATORY SCIENCE | 2023年 / 53卷 / 05期
关键词
Pulmonary cryptococcosis; Cryptococcal antigen; Bronchial lavage fluid; lateral flow assay; PULMONARY CRYPTOCOCCOSIS; INFECTIONS; DISEASE;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective. We presented the performance of cryptococcal antigen lateral flow assay test using bronchoalveolar lavage fluid (BALF) samples in the HIV-negative Chinese population. Methods. From January 2019 to June 2022, cryptococcal antigen was detected in both serum and BALF samples from 113 patients with suspected pulmonary cryptococcosis. Results. 49 patients were finally diagnosed with pulmonary cryptococcosis. The sensitivity of cryptococcal antigen lateral flow assay test in serum and BALF specimens from confirmed cases was 90.0% and 96.0%, respectively, and the specificity was 87.3% and 95.5%, respectively. When the diameter of the lung lesion was less than 15 mm, the antigen positivity rate of BALF was higher than that of serum. Moreover, the result of the cryptococcal antigen test was associated with the lymphocytes count of BALF. Conclusion. Our data demonstrate that cryptococcal antigen Lateral Flow Assay for BALF specimens might contribute to the early diagnosis of pulmonary cryptococcosis.
引用
收藏
页码:765 / 770
页数:6
相关论文
共 50 条
  • [1] Examination of cryptococcal glucuronoxylomannan antigen in bronchoalveolar lavage fluid for diagnosing pulmonary cryptococcosis in HIV-negative patients
    Oshima, Kazuhiro
    Takazono, Takahiro
    Saijo, Tomomi
    Tashiro, Masato
    Kurihara, Shintaro
    Yamamoto, Kazuko
    Imamura, Yoshifumi
    Miyazaki, Taiga
    Tsukamoto, Misuzu
    Yanagihara, Katsunori
    Mukae, Hiroshi
    Kohno, Shigeru
    Izumikawa, Koichi
    MEDICAL MYCOLOGY, 2018, 56 (01) : 88 - 94
  • [2] Diagnostic performance of the IMMY cryptococcal antigen lateral flow assay on serum and cerebrospinal fluid for diagnosis of cryptococcosis in HIV-negative patients: a systematic review
    Macrae, Catriona
    Ellis, Jayne
    Keddie, Suzanne H.
    Falconer, Jane
    Bradley, John
    Keogh, Ruth
    Baerenbold, Oliver
    Hopkins, Heidi
    Jarvis, Joseph N.
    BMC INFECTIOUS DISEASES, 2023, 23 (01)
  • [3] Diagnostic performance of the IMMY cryptococcal antigen lateral flow assay on serum and cerebrospinal fluid for diagnosis of cryptococcosis in HIV-negative patients: a systematic review
    Catriona Macrae
    Jayne Ellis
    Suzanne H. Keddie
    Jane Falconer
    John Bradley
    Ruth Keogh
    Oliver Baerenbold
    Heidi Hopkins
    Joseph N. Jarvis
    BMC Infectious Diseases, 23
  • [4] Diagnostic value of bronchoalveolar lavage fluid cryptococcal antigen- lateral flow immunochromatographic assay for pulmonary cryptococcosis in non-HIV patients
    Zeng, Hui-Qing
    Zhang, Xiao-Bin
    Cai, Xue-Ying
    Yang, Dong-Yong
    Lin, Li
    Chen, Mei-Jun
    Guo, Wei-Feng
    Luo, Xiongbiao
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2021, 99 (03)
  • [5] Examination of a Chinese-made cryptococcal glucuronoxylomannan antigen test in serum and bronchoalveolar lavage fluid for diagnosing pulmonary cryptococcosis in HIV-negative patients
    Li, Zhengtu
    Wang, Mingdie
    Zeng, Peiying
    Chen, Zhaoming
    Zhan, Yangqing
    Li, Shaoqiang
    Lin, Ye
    Cheng, Jing
    Ye, Feng
    JOURNAL OF MICROBIOLOGY IMMUNOLOGY AND INFECTION, 2022, 55 (02) : 307 - 313
  • [6] Evaluation of low cryptococcal antigen titer as determined by the lateral flow assay in serum and cerebrospinal fluid among HIV-negative patients: a retrospective diagnostic accuracy study
    Wang, Xuan
    Cheng, Jia-Hui
    Zhou, Ling-Hong
    Zhu, Jun-Hao
    Wang, Rui-Ying
    Zhao, Hua-Zhen
    Jiang, Ying-Kui
    Huang, Li-Ping
    Yip, Ching-Wan
    Que, Chun-Xing
    Zhu, Min
    Zhu, Li-Ping
    IMA FUNGUS, 2020, 11 (01)
  • [7] Evaluation of low cryptococcal antigen titer as determined by the lateral flow assay in serum and cerebrospinal fluid among HIV-negative patients: a retrospective diagnostic accuracy study
    Xuan Wang
    Jia-Hui Cheng
    Ling-Hong Zhou
    Jun-Hao Zhu
    Rui-Ying Wang
    Hua-Zhen Zhao
    Ying-Kui Jiang
    Li-Ping Huang
    Ching-Wan Yip
    Chun-Xing Que
    Min Zhu
    Li-Ping Zhu
    IMA Fungus, 11
  • [8] Performance of the Lateral Flow Assay and the Latex Agglutination Serum Cryptococcal Antigen Test in Cryptococcal Disease in Patients with and without HIV
    Hevey, Matthew A.
    George, Ige A.
    Rauseo, Adriana M.
    Larson, Lindsey
    Powderly, William
    Spec, Andrej
    JOURNAL OF CLINICAL MICROBIOLOGY, 2020, 58 (11)
  • [9] Utility of routine testing of bronchoalveolar lavage fluid for cryptococcal antigen
    Kralovic, SM
    Rhodes, JC
    JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (10) : 3088 - 3089
  • [10] Performance of the Cryptococcal Antigen Lateral Flow Assay in Non-HIV-Related Cryptococcosis
    Jitmuang, Anupop
    Panackal, Anil A.
    Williamson, Peter R.
    Bennett, John E.
    Dekker, John P.
    Zelazny, Adrian M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (02) : 460 - 463