摘要
Compared with the traditional grid-following photovoltaic grid-connected converter (GFL-PGC), the grid-forming photovoltaic grid-connected converter (GFM-PGC) can provide voltage and frequency support for power systems, which can effectively enhance the stability of power electronic power systems. Consequently, GFM-PGCs have attracted great attention in recent years. When an asymmetrical short-circuit fault occurs in the power grid, GFM-PGC systems may experience transient instability, which has been less studied so far. In this paper, a GFM-PGC system is investigated under asymmetrical short-circuit fault conditions. A novel Q-V droop control structure is proposed by improving the traditional droop control. The proposed control structure enables the system to accurately control the positive- and negative-sequence reactive current without switching the control strategy during the low-voltage ride-through (LVRT) period so that it can meet the requirements of the renewable energy grid code. In addition, a dual-loop control structure model of positive- and negative-sequence voltage and current is established for the GFM-PGC system under asymmetrical short-circuit fault conditions. Based on the symmetrical component method, the composite sequence network of the system is obtained under asymmetrical short-circuit fault conditions, and positive- and negative-sequence power-angle characteristic curves are analyzed. The influence law of system parameters on the transient synchronous stability of positive- and negative-sequence systems is quantitatively analyzed through the equal area criterion. Finally, the correctness of the theoretical analysis is verified by simulation and hardware-in-the-loop experiments.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Grid-Forming Inverters for Grid-Connected Microgrids
    Tuckey, Andrew
    Round, Simon
    IEEE ELECTRIFICATION MAGAZINE, 2022, 10 (01): : 39 - 51
  • [2] Transient Stability Analysis for Grid-Forming Inverters Transitioning from Islanded to Grid-Connected Mode
    Liu, Teng
    Wang, Xiongfei
    Liu, Fangcheng
    Xin, Kai
    Liu, Yunfeng
    IEEE OPEN JOURNAL OF POWER ELECTRONICS, 2022, 3 : 419 - 432
  • [3] Improving the performance of grid-connected inverters during asymmetrical faults and unbalanced grid voltages
    Shabani, Sepideh
    Gholipour, Mehdi
    Niroomand, Mehdi
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (19) : 3097 - 3107
  • [4] Transient Synchronization Stability Analysis of Grid-forming Grid-connected Inverter Considering Damping Characteristics
    Li M.
    Wu Z.
    Quan X.
    Zhu L.
    Li W.
    Huang R.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (15): : 198 - 207
  • [5] Stability Analysis of Grid-Connected Inverters during the Transient of Grid Voltage Fluctuations in Weak Grid Cases
    Xu, Jinming
    Bian, Shenyiyang
    Liu, Miao
    Zhang, Zhao
    Xie, Shaojun
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 5185 - 5190
  • [6] Stability Analysis of Parallel Grid-Forming Inverters in Asymmetrical Conditions
    Akhavan, Ali
    Vasquez, Juan C.
    Guerrero, Josep M.
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN INDUSTRIAL ELECTRONICS, 2024, 5 (03): : 1344 - 1348
  • [7] Stability Control for Grid-Connected Inverters Based on Hybrid-Mode of Grid-Following and Grid-Forming
    Han, Feng
    Zhang, Xing
    Li, Ming
    Li, Fei
    Zhao, Wei
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (09) : 10750 - 10760
  • [8] Collaborative Autonomous Grid-Connected Inverters Flexible grid-forming inverter control for the future grid
    Benzaquen, Joseph
    Miranbeigi, Mohammadreza
    Kandula, Prasad
    Divan, Deepak
    IEEE ELECTRIFICATION MAGAZINE, 2022, 10 (01): : 22 - 29
  • [9] Transient stability analysis of a grid-connected type-4 wind turbine with grid-forming control during the fault
    Gao, Zhen
    Du, Wenjuan
    Wang, H. F.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155
  • [10] Transient Stability of Grid-Forming Inverters in Microgrids: Nonlinear Analysis
    Eskandari, Mohsen
    Savkin, Andrey, V
    16TH IEEE INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION (ICARCV 2020), 2020, : 1156 - 1159