Clinical magnetocardiography: the unshielded bet-past, present, and future

被引:22
作者
Brisinda, D. [1 ,2 ,3 ]
Fenici, P. [2 ,3 ]
Fenici, R. [3 ]
机构
[1] Fdn Policlin Univ Agostino Gemelli, Dipartimento Sci Invecchiamento Ortoped & Reumatol, IRCCS, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Sch Med & Surg, Rome, Italy
[3] Biomagnetism & Clin Physiol Int Ctr BACPIC, Rome, Italy
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2023年 / 10卷
关键词
magnetocardiography (MCG); electrophysiology arrhythmias mapping and ablation; source localization accuracy; inverse problem; electroanatomical imaging; magnetic sensors; gradiometer array; magnetically shielded room (MSR); CORONARY-ARTERY-DISEASE; S-T SEGMENT; MAGNETIC-FIELD; NONFLUOROSCOPIC LOCALIZATION; ATRIAL-FIBRILLATION; ELECTRICAL-ACTIVITY; QRS FRAGMENTATION; INVERSE PROBLEM; RESOLUTION MAGNETOCARDIOGRAPHY; VENTRICULAR DEPOLARIZATION;
D O I
10.3389/fcvm.2023.1232882
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetocardiography (MCG), which is nowadays 60 years old, has not yet been fully accepted as a clinical tool. Nevertheless, a large body of research and several clinical trials have demonstrated its reliability in providing additional diagnostic electrophysiological information if compared with conventional non-invasive electrocardiographic methods. Since the beginning, one major objective difficulty has been the need to clean the weak cardiac magnetic signals from the much higher environmental noise, especially that of urban and hospital environments. The obvious solution to record the magnetocardiogram in highly performant magnetically shielded rooms has provided the ideal setup for decades of research demonstrating the diagnostic potential of this technology. However, only a few clinical institutions have had the resources to install and run routinely such highly expensive and technically demanding systems. Therefore, increasing attempts have been made to develop cheaper alternatives to improve the magnetic signal-to-noise ratio allowing MCG in unshielded hospital environments. In this article, the most relevant milestones in the MCG's journey are reviewed, addressing the possible reasons beyond the currently long-lasting difficulty to reach a clinical breakthrough and leveraging the authors' personal experience since the early 1980s attempting to finally bring MCG to the patient's bedside for many years thus far. Their nearly four decades of foundational experimental and clinical research between shielded and unshielded solutions are summarized and referenced, following the original vision that MCG had to be intended as an unrivaled method for contactless assessment of the cardiac electrophysiology and as an advanced method for non-invasive electroanatomical imaging, through multimodal integration with other non-fluoroscopic imaging techniques. Whereas all the above accounts for the past, with the available innovative sensors and more affordable active shielding technologies, the present demonstrates that several novel systems have been developed and tested in multicenter clinical trials adopting both shielded and unshielded MCG built-in hospital environments. The future of MCG will mostly be dependent on the results from the ongoing progress in novel sensor technology, which is relatively soon foreseen to provide multiple alternatives for the construction of more compact, affordable, portable, and even wearable devices for unshielded MCG inside hospital environments and perhaps also for ambulatory patients.
引用
收藏
页数:24
相关论文
共 334 条
[1]   MAGNETOCARDIOGRAPHY - CLINICAL INVESTIGATIONS WITH A BIOMAGNETIC MULTICHANNEL SYSTEM [J].
ACHENBACH, S ;
MOSHAGE, W .
PHYSIOLOGICAL MEASUREMENT, 1993, 14 :A61-A68
[2]   Calibration of Room Temperature Magnetic Sensor Array for Biomagnetic Measurement [J].
Adachi, Yoshiaki ;
Oyama, Daisuke ;
Terazono, Yasushi ;
Hayashi, Tatsuya ;
Shibuya, Tomohiko ;
Kawabata, Shigenori .
IEEE TRANSACTIONS ON MAGNETICS, 2019, 55 (07)
[3]   Noninvasive Mapping of Premature Ventricular Contractions by Merging Magnetocardiography and Computed Tomography [J].
Aita, Satoshi ;
Ogata, Kuniomi ;
Yoshida, Kentaro ;
Inaba, Takeshi ;
Kosuge, Hisanori ;
Machino, Takeshi ;
Tsumagari, Yasuaki ;
Hattori, Ai ;
Ito, Yoko ;
Komatsu, Yuki ;
Sekihara, Kensuke ;
Horigome, Hitoshi ;
Aonuma, Kazutaka ;
Nogami, Akihiko ;
Kandori, Akihiko ;
Ieda, Masaki .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (10) :1144-1157
[4]   A CONSENSUS STATEMENT ON RELATIVE MERITS OF EEG AND MEG - EUROPEAN CONCERTED ACTION ON BIOMAGNETISM, LYON MEETING, NOVEMBER 26 AND 27, 1991 [J].
ANOGIANAKIS, G ;
BADIER, JM ;
BARRETT, G ;
ERNE, S ;
FENICI, R ;
FENWICK, P ;
GRANDORI, F ;
HARI, R ;
ILMONIEMI, R ;
MAUGUIERE, F ;
LEHMANN, D ;
PERRIN, F ;
PETERS, M ;
ROMANI, GL ;
ROSSINI, PM .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 82 (05) :317-319
[5]  
[Anonymous], 2007, INT C SER, DOI DOI 10.1016/J.ICS.2006.12.061
[6]  
[Anonymous], 2004, NEUROL CLIN NEUROPHY
[7]   Millimetre-scale magnetocardiography of living rats with thoracotomy [J].
Arai, Keigo ;
Kuwahata, Akihiro ;
Nishitank, Daisuke ;
Fujisaki, Ikuya ;
Matsuki, Ryoma ;
Nishio, Yuki ;
Xin, Zonghao ;
Cao, Xinyu ;
Hatancy, Yuji ;
Onoda, Shinobu ;
Shinei, Chikara ;
Miyakawa, Masashi ;
Taniguchi, Takashi ;
Yamazaki, Masatoshi ;
Teraji, Tokuyuki ;
Ohshima, Takeshi ;
Hatano, Mutsuko ;
Sekino, Masaki ;
Iwasaki, Takayuki .
COMMUNICATIONS PHYSICS, 2022, 5 (01)
[8]   Potential clinical relevance of the 'little brain' on the mammalian heart [J].
Armour, J. A. .
EXPERIMENTAL PHYSIOLOGY, 2008, 93 (02) :165-176
[9]  
Bakharev AA., 2003, United States Patent Office, Patent No. [2003/0141868A1, 20030141868]
[10]   Repolarization Heterogeneity of Magnetocardiography Predicts Long-Term Prognosis in Patients with Acute Myocardial Infarction [J].
Bang, Woo-Dae ;
Kim, Kiwoong ;
Lee, Yong-Ho ;
Kwon, Hyukchan ;
Park, Yongki ;
Pak, Hui-Nam ;
Ko, Young-Guk ;
Lee, Moonhyoung ;
Joung, Boyoung .
YONSEI MEDICAL JOURNAL, 2016, 57 (06) :1339-1346