A multi-institutional assessment of eye lens dose in nuclear medicine clinics

被引:0
|
作者
Abuqbeitah, Mohammad [1 ]
Demir, Mustafa [1 ]
Isikci, Nazenin Ipek [2 ]
Kozanlilar, Burcu [3 ]
Kovan, Bilal [4 ]
Yeyin, Nami [1 ]
Cermik, Tevik Fikret [3 ]
Sanli, Yasemin [4 ]
Sonmezoglu, Kerim [1 ]
机构
[1] Istanbul Univ Cerrahpasa, Cerrahpasa Fac Med, Dept Nucl Med, TR-34098 Istanbul, Turkiye
[2] Nisantasi Univ, Fac Engn & Architecture, Dept Genet & Bioengn, Istanbul, Turkiye
[3] Istanbul Training & Res Hosp, Clin Nucl Med, Istanbul, Turkiye
[4] Istanbul Univ, Istanbul Fac Med, Dept Nucl Med, Istanbul, Turkiye
关键词
lens dose; nuclear medicine; optically stimulated luminescence (0; 3 cm); RADIATION; DOSIMETRY; RISKS;
D O I
10.1097/MNM.0000000000001727
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AimThe endeavor was to measure the lens dose of actively working staff in nuclear medicine departments. Material and methodsThis study was accomplished in three nuclear medicine sites. A total of 23 workers in nuclear medicine joined this work. Among them are 6 SPECT/ CT technologists, 6 PET/CT technologists, 3 PET/MRI technologists, 5 radiopharmacists, 2 physicists, and 1 physician. EXTDOSE Hp(3) OSL dosimeter with tissue equivalent beryllium-oxide crystal was used for lens dose measurement. All participants were asked to wear the lens dosimeter for 2 months as near to the eye level as possible. ResultsPooling the dose measures together yielded an average lens dose of 1.48 & PLUSMN; 0.77 mSv for the radiopharmacy team, 1.44 & PLUSMN; 0.26 for PET/ CT technologists, 0.86 & PLUSMN; 0.45 mSv for SPECT/ CT technologists, 0.38 mSv for the sole physician administered 177Lu, and 0.45 & PLUSMN; 0.02 mSv for the physicists conducting 131I therapy. Moreover, normalizing the lens dose to the labeled activity led to a lens dose of 2.2 & PLUSMN; 1.4 & mu;Sv/GBq for the radiopharmacy team. Likewise, per administered activity: 23.8 & PLUSMN; 7.3 & mu;Sv/GBq for PET/CT and PET/MRI technologists, 12.2 & PLUSMN; 10.5 & mu;Sv/GBq 99mTc for SPECT/CT technologists, 6.0 & PLUSMN; 0.81 & mu;Sv/GBq 131I for physicists, and 3.0 & mu;Sv/GBq 177Lu for the physician. ConclusionIt was deduced that the annual occupational lens dose of the nuclear medicine workers varied from 2.3 to 11.5 mSv/year; however, one radiopharmacist projected annual lens dose as close to the lens equivalent dose limit (20 mSv/year) as 17.9 mSv.
引用
收藏
页码:772 / 776
页数:5
相关论文
共 49 条
  • [31] Occupational radiation dose assessment of professionals working in a nuclear medicine and PET/CT centre
    Alkhybari, Essam M.
    Faqeeh, Jafar M.
    Albatly, Abdulrahman A.
    Altimyat, Salman
    Alruwaili, Turki
    Soliman, Khaled
    Alsheikh, Hanaa
    Al-Qahtani, Saeed Mueed
    Abualnaja, Asim
    Alrakaf, Waleed Suliman
    Alyami, Wadha
    Alahmari, Faisal
    Sulieman, Abdelmoneim
    Bradley, David A.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 232
  • [32] OLINDA/EXM 2-The Next-generation Personal Computer Software for Internal Dose Assessment in Nuclear Medicine
    Stabin, Michael G.
    HEALTH PHYSICS, 2023, 124 (05): : 397 - 406
  • [33] Dose escalated simultaneous integrated boost of gross nodal disease in gynecologic cancers: a multi-institutional retrospective analysis and review of the literature
    Jensen, Garrett Lee
    Mezera, Megan Ann
    Hasan, Salman
    Hammonds, Kendall Pye
    Swanson, Gregory Peter
    El-Ghamry, Moataz Nier
    RADIATION ONCOLOGY JOURNAL, 2021, 39 (03): : 219 - 230
  • [34] Assessment of scatter radiation dose and absorbed doses in eye lens and thyroid gland during digital breast tomosynthesis
    Chusin, Thunyarat
    Matsubara, Kosuke
    Takemura, Akihiro
    Okubo, Rena
    Ogawa, Yoshinori
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 340 - 347
  • [35] PATIENT RADIATION DOSE ASSESSMENT SYSTEM FOR DIAGNOSTIC NUCLEAR MEDICINE PROCEDURES: IMPLEMENTATION AND FIRST RESULTS
    Dundara Debeljuh, Dea
    Jurkovic, Slaven
    Pribanic, Ivan
    Girotto, Neva
    Grbac-Ivankovic, Svjetlana
    Bozanic, Ana
    Segota, Doris
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2020, 35 (04) : 380 - 385
  • [36] Gonad dose assessment in paediatric kidney nuclear medicine test using Monte Carlo simulation
    Lee, Dong-Yeon
    Kye, Yong-Uk
    Kim, Hyo-Jin
    Kim, Jeung-Kee
    Kang, Yeong-Rok
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (06) : 895 - 902
  • [37] Protocol for the measurement of the absorbed dose rate to water for a planar 32P beta emitting brachytherapy source: A multi-institutional validation
    Mulet, Liana
    Barreto, Izabella
    Cohen, Gil'ad N.
    Damato, Antonio L.
    Mauceri, Thomas
    Pursley, Jennifer
    Deufel, Christopher L.
    BRACHYTHERAPY, 2022, 21 (01) : 120 - 127
  • [38] A multi-institutional study of secondary check of treatment planning using Clarkson-based dose calculation for three-dimensional radiotherapy
    Takahashi, Ryo
    Kamima, Tatsuya
    Itano, Masanobu
    Yamazaki, Takeshi
    Ishibashi, Satoru
    Higuchi, Yoshihiro
    Shimizu, Hiroyuki
    Yamamoto, Toshijiro
    Yamashita, Mikiko
    Baba, Hiromi
    Sugawara, Yasuharu
    Sato, Aya
    Nishiyama, Shiro
    Kawai, Daisuke
    Miyaoka, Satoshi
    Tachibana, Hidenobu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 49 : 19 - 27
  • [39] Assessment of head CT protocol to reduce the radiation dose in eye lens in some selected hospital in Kaduna State, Nigeria
    Abdulhamid, Musa
    Ibrahim, Umar
    Zira, Joseph Dlama
    Yusuf, Samson D.
    Abdulhamid, Abdulqadir
    APPLIED RADIATION AND ISOTOPES, 2022, 190
  • [40] 131I INTERNAL CONTAMINATION AND COMMITTED DOSE ASSESSMENT AMONG NUCLEAR MEDICINE MEDICAL PERSONNEL
    Brudecki, K.
    Kluczewska-Galka, A.
    Mroz, T.
    Jarzab, B.
    Zagrodzki, P.
    Janowski, P.
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (03) : 275 - 281