Experimental results of reinforced concrete frames with masonry infills with and without openings under combined quasi-static in-plane and out-of-plane seismic loading

被引:7
作者
Milijas, Aleksa [1 ]
Marinkovic, Marko [2 ]
Butenweg, Christoph [3 ]
Klinkel, Sven [1 ]
机构
[1] Rhein Westfal TH Aachen, Chair Struct Anal & Dynam, Mies Van Der Rohe Str 1, D-52074 Aachen, Germany
[2] Univ Belgrade, Fac Civil Engn, Chair Engn Mech & Theory Struct, Bulevar kralja Aleksandra 73, Belgrade 11000, Serbia
[3] Rhein Westfal TH Aachen, Ctr Wind & Earthquake Engn, Mies Van Der Rohe Str 1, D-52074 Aachen, Germany
关键词
Masonry infill; Reinforced concrete frame; Openings; Interaction; Earthquake; BEHAVIOR; PERFORMANCE; STRENGTH; WALLS; EARTHQUAKE; BUILDINGS; MODEL; RATIO;
D O I
10.1007/s10518-023-01664-4
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Reinforced concrete (RC) frames with masonry infills can be encountered all over the world, especially in earthquake prone regions. Although masonry infills are usually not considered in the design process, in the case of seismic loading they are subjected to in-plane and out-of-plane forces that can act separately or simultaneously. In recent earthquakes it was observed that seismic loads can severely damage masonry infills or even cause their complete collapse, especially when the loads act simultaneously. Due to this, effects of interaction of in-plane and out-of-plane loads on seismic performance of masonry infills have received more attention recently. However, most of studies focus only on fully infilled frames, even though openings, such as windows and doors are essential parts of infills that substantially affect the seismic response of masonry infills. Therefore, this article presents the results of a comprehensive experimental study on nine full-scale traditional masonry RC frames infilled with modern hollow clay bricks for configurations with and without window and door openings under separate, sequential and combined in-plane and out-of-plane loading. Based on the results, a detailed comparison and interpretation for the different infill and loading configurations is presented. The test results clearly show the unfavourable influence of openings and combined loading conditions as well as the importance of the quality of execution of the circumferential mortar joint between infill and frame. The new findings can be used as a basis for the required development of innovative solutions to improve significantly the seismic performance of RC frames with masonry infills.
引用
收藏
页码:3537 / 3579
页数:43
相关论文
共 89 条
  • [61] Experimental evaluation of masonry-infilled RC frames
    Mehrabi, AB
    Shing, PB
    Schuller, MP
    Noland, JL
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (03): : 228 - 237
  • [62] Moghaddam HA, 1987, 872 ESEE
  • [63] Innovative solution for seismic-resistant masonry infills with sliding joints: in-plane experimental performance
    Morandi, P.
    Milanesi, R. R.
    Magenes, G.
    [J]. ENGINEERING STRUCTURES, 2018, 176 : 719 - 733
  • [64] Morandi P, 2013, P 15 ANIDIS ING SISM, P30
  • [65] Morandi P, 2017, APPENDIX GUKELINE PR
  • [66] Morandi P, 2022, P 3 EUR C EARTHQ ENG
  • [67] Performance-based interpretation of in-plane cyclic tests on RC frames with strong masonry infills
    Morandi, Paolo
    Hak, Sanja
    Magenes, Guido
    [J]. ENGINEERING STRUCTURES, 2018, 156 : 503 - 521
  • [68] Static response of infilled frames using quasi-static experimentation
    Mosalam, KM
    White, RN
    Gergely, P
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1997, 123 (11): : 1462 - 1469
  • [69] Nam PH, 2019, ARXIV, DOI DOI 10.48550/ARXIV.1907.10263