Investigative analysis of the impact of the climatic induced pollution upon the insulators in 500 kV HVDC transmission line

被引:3
|
作者
Wadie, Fady [1 ]
机构
[1] Egyptian Russian Univ, Fac Engn, Mechatron & Robot Engn Dept, Badr City, Egypt
关键词
LIGHTNING PROTECTION; VOLTAGE; FLASHOVER; BEHAVIOR; STROKES;
D O I
10.1016/j.epsr.2023.109244
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The increasing effect of climatic change has mandated the investigation of its negative impact upon electrical power systems. One of the most vulnerable parts of the power system to climatic conditions is the transmission line. Among transmission line technologies, high voltage direct current (HVDC) transmission systems are gaining attention in last decades for their various applications in long distance power transmission and asynchronized connections. In this paper, HVDC transmission system was simulated using ATP/EMTP software package. The insulators of the system were tested for different lightning types under clean and polluted conditions. To evaluate the amount of reduction in insulation performance, two factors were identified as risk of back flashover factor (RBF) and the degradation factor. The computation of RBF was dependent on the parameters of the strike leading to back flashover and the probability of its occurrence. The degradation factor was defined as the percentage of increase of RBF due to polluted conditions. The degradation factor was computed for negative, positive and indirect strikes to be 92%, 29.2% and 33.3% respectively. The results indicate that the climatic pollutive impact could lead to severe degradation that could double the RBF as in negative strikes.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Comparison between artificial pollution and nature pollution of 500 kV transmission line insulators in East China grid
    Qian, Zhi-Yin
    Xiao, Rong
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (03): : 705 - 710
  • [2] Measurement of Pollution Level of 66 kV Transmission Line Insulators
    Salam, M. A.
    Ang, S. P.
    Ong, B. T.
    Malik, Owais A.
    Voon, William
    Alinurrezan, M.
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 1124 - 1127
  • [3] Experimental study on lighting shielding performance of ±500 kV HVDC transmission line
    He, Heng-Xin
    He, Jun-Jia
    Jiang, Zheng-Long
    Wang, Cheng
    Ye, Hui-Sheng
    Wang, Xin-Xiu
    Bian, Kai
    Xie, Shi-Jun
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2009, 29 (07): : 20 - 26
  • [4] Analysis on lightning withstand performance of the Sanhu ±500 kV double circuit HVDC power transmission line
    Tan, Jin
    Zhang, Huan-Qing
    Liu, Yu-Jun
    Liang, Jian
    Tang, Cheng
    Liu, Gang
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (09): : 2173 - 2179
  • [5] Corona suppression of grading rings on suspension composite insulators on 500 kV compact transmission line
    Xie, Tian-Xi
    Mo, Juan
    Peng, Zong-Ren
    Li, Jing
    Fu, Xiao-Yong
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (07): : 1779 - 1784
  • [6] Design and Technical Analysis of 500-600 kV HVDC Transmission System for Turkey
    Font, Aytug
    Ilhan, Suat
    Ismailoglu, Hasbi
    Cortes, Fermin Espino
    Ozdemir, Aydogan
    2017 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2017, : 201 - 205
  • [7] Study of Switching Overvoltage for Metallic Return Line of ±500kV Flexible HVDC Transmission Project
    Li, Xiaolan
    Zhou, Peihong
    Cao, Zhaojun
    10TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC 2018), 2018, : 113 - 120
  • [8] The need of creating a new nominal creepage distance in accordance with heaviest pollution 500 kV overhead line insulators
    Arias Velasquez, Ricardo Manuel
    Mejia Lara, Jennifer Vanessa
    ENGINEERING FAILURE ANALYSIS, 2018, 86 : 21 - 32
  • [9] Research on induced current and induced voltage of 500 kV double circuit transmission line
    Ren Hongtao
    Zhang Ying
    ENERGY REPORTS, 2021, 7 : 216 - 223
  • [10] Fault analysis and modified measures of 500 kV compact transmission line
    Wang, Li-Ming
    Sun, Bao-Qiang
    Hou, Lei
    Fu, Guan-Jun
    Meng, Xiao-Bo
    Guan, Zhi-Cheng
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (09): : 2108 - 2113