A New Low Switching Frequency Control of Regenerative CHB Drive With Low-Voltage Ride-Through Capability

被引:5
|
作者
Ni, Zhituo [1 ]
Abuelnaga, Ahmed H. [1 ]
Badawi, Sarah [2 ]
Yuan, Shaoyi [2 ]
Narimani, Mehdi [2 ]
Sayed-Ahmed, Ahmed [3 ]
Cheng, Zhongyuan [1 ]
Zargari, Navid R. [1 ]
机构
[1] Rockwell Automat Inc, Cambridge, ON N1R 5N9, Canada
[2] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON L8S 4L8, Canada
[3] Rockwell Automat Inc, Milwaukee, WI 53204 USA
基金
加拿大自然科学与工程研究理事会;
关键词
Harmonic analysis; Insulated gate bipolar transistors; Switching frequency; Switches; Control systems; Transformers; IEEE Standards; Low grid voltage ride-through; low-frequency modulation strategy; multilevel regenerative drives; POWER QUALITY; SPEED DRIVES;
D O I
10.1109/TPEL.2022.3216001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In conventional medium-voltage high-power cascaded H-bridge (CHB) drive, a three-phase rectifier is adopted in each power cell to provide isolated dc-bus voltage for the output H-bridge. This limits the application of the conventional CHB drive, where regeneration capability is desired. The regenerative CHB drive can be made possible by replacing the diode rectifier with a three-phase IGBT-based active-front-end (AFE) rectifier in each power cell. However, due to thermal constraints in the high-power medium-voltage drives, the first challenge of the regenerative CHB drive is to deal with the extra switching losses introduced by the IGBT devices. Another challenge of the grid-tied regenerative CHB drive is to handle the low-voltage sags in the power grid without triggering unnecessary downtime in transients. In this article, a novel low-switching frequency control strategy is proposed for the AFEs in the regenerative CHB drive with low-voltage ride-through (LVRT) capability. The main harmonic contents generated by the AFEs with the proposed control strategy can be eliminated by the existing phase-shifting transformer in the CHB drives. This allows meeting with IEEE STD 519-2014 requirement with a 60 Hz switching frequency to minimize the extra introduced switching losses in steady state. Moreover, LVRT capability is integrated into the proposed control scheme with reduced current sensor count. Accompanied with videos, the experiments on a seven-level regenerative CHB drive are implemented to validate the feasibility of the proposed control scheme, which can be extended to regenerative CHB drives with any voltage levels.
引用
收藏
页码:1973 / 1983
页数:11
相关论文
共 50 条
  • [21] A coordinated control and management strategy of a wind energy conversion system for a universal low-voltage ride-through capability
    Marmouh, Soufiane
    Boutoubat, Mohamed
    Mokrani, Lakhdar
    Machmoum, Mohamed
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (08):
  • [22] Low-voltage ride-through control strategy for flywheel energy storage system
    Zheng, Xuechen
    Wu, Zhenkui
    Song, Gengling
    Zhang, Jihong
    Yang, Peihong
    Zhang, Zilei
    Lu, Xingsheng
    ENERGY SCIENCE & ENGINEERING, 2024, 12 (04) : 1486 - 1502
  • [23] Improvement Low-Voltage Ride-Through Control of DFIG During Grid Faults
    Riouch, Tariq
    El-Bachtiri, Rachid
    2014 INTERNATIONAL CONFERENCE ON MULTIMEDIA COMPUTING AND SYSTEMS (ICMCS), 2014, : 1596 - 1601
  • [24] Low-Voltage Ride-Through Capability of a Single-Stage Single-Phase Photovoltaic System Connected to the Low-Voltage Grid
    Yang, Yongheng
    Blaabjerg, Frede
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2013, 2013
  • [25] A Cut-Out Strategy for Wind Turbines that Ensures Low-Voltage Ride-Through Capability
    Aiguo Tan
    Zhihan Tang
    Xianbo Sun
    Jianwei Zhong
    Honghua Liao
    Haibing Fang
    Journal of Electrical Engineering & Technology, 2020, 15 : 1567 - 1575
  • [26] A Cut-Out Strategy for Wind Turbines that Ensures Low-Voltage Ride-Through Capability
    Tan, Aiguo
    Tang, Zhihan
    Sun, Xianbo
    Zhong, Jianwei
    Liao, Honghua
    Fang, Haibing
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (04) : 1567 - 1575
  • [27] Analysis and Enhancement of Low-Voltage Ride-Through Capability of Brushless Doubly Fed Induction Generator
    Tohidi, Sajjad
    Oraee, Hashem
    Zolghadri, Mohammad Reza
    Shao, Shiyi
    Tavner, Peter
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (03) : 1146 - 1155
  • [28] Fault Ride-Through Capability with Mutual Inductance in Low-Voltage Single-Phase Microgrid
    Salem, Qusay
    Alzaareer, Khaled
    IETE JOURNAL OF RESEARCH, 2022, 68 (06) : 4610 - 4619
  • [29] Improvement of the Low-voltage Ride-through Capability of Doubly Fed Induction Generator Wind Turbines
    Ling, Yu
    Dou, Zhenlan
    Gao, Qiang
    Cai, Xu
    WIND ENGINEERING, 2012, 36 (05) : 535 - 551
  • [30] PV Power System With Multi-Mode Operation and Low-Voltage Ride-Through Capability
    Tang, Cheng-Yu
    Chen, Yao-Ting
    Chen, Yaow-Ming
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (12) : 7524 - 7533