Experimental Study on Seismic Behavior of Lightweight Concrete-Filled Cold-Formed Steel Shear Walls Strengthened Using Horizontal Reinforcement

被引:2
作者
Xu, Zhifeng [1 ,2 ,5 ]
Chen, Zhongfan [1 ,3 ]
Dong, Xitong [2 ,4 ]
Zuo, Yining [2 ,4 ]
机构
[1] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Nanjing, Peoples R China
[2] Shandong Univ Sci & Technol, Coll Civil Engn & Architecture, Qingdao, Peoples R China
[3] Southeast Univ, Sch Civil Engn, Nanjing, Peoples R China
[4] Shandong Univ Sci & Technol, Shandong Key Lab Civil Engn Disaster Prevent & Mit, Qingdao, Peoples R China
[5] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Nanjing 211189, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel concrete shear wall; lightweight concrete; quasi-static test; seismic performance; calculation method; FOAMED CONCRETE; CYCLIC PERFORMANCE; MODEL;
D O I
10.1080/13632469.2022.2162630
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To improve the seismic behavior and thermal property of traditional cold-formed steel (CFS) walls for satisfying the requirements multistory structures, a new type of fiber-reinforced lightweight concrete (FLC)-filled CFS shear wall strengthened using horizontal reinforcement is proposed in this study. Four full-scale specimens were tested under reversed cyclic loading to investigate the seismic behavior, including failure mode, hysteresis curve, shear capacity, deformability, stiffness degradation, and energy-dissipating capacity. Test results indicated that the restrictive effect of FLC on the studs and its diagonal-bracing effect improved the wall's hysteretic behavior, making the wall exhibit the ductile shear failure. Increasing the wall thickness increased the shear strength, lateral stiffness, and energy-dissipating capacity, whereas installing the coupling-section interior studs enhanced the ductility. Finally, a simplified strut-and-tie model was proposed to evaluate the shear capability of FLC-filled walls, and the calculated values exhibited good agreement with the test results, but the further verification is required.
引用
收藏
页码:4126 / 4160
页数:35
相关论文
共 37 条
  • [1] ASTM E2126-2018,, 2018, STANDARD TEST METHOD
  • [2] Experimental Research on Properties of High-Strength Foamed Concrete
    Bing, Chen
    Zhen, Wu
    Ning, Liu
    [J]. JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2012, 24 (01) : 113 - 118
  • [3] Experimental Study on Shear Behavior of Meshwork Cold-formed Thin-wall Steel RC Shear Wall
    Chen Zhongfan
    Gao Wei
    [J]. SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 1291 - 1294
  • [4] FEMA. 356,, 2015, PRESTANDARD COMMENTA
  • [5] [冯鹏 Feng Peng], 2010, [建筑结构学报, Journal of Building Structures], V31, P83
  • [6] Experimental investigation of seismic behaviour of low dissipative CFS strap-braced stud walls
    Fiorino, Luigi
    Terracciano, Maria Teresa
    Landolfo, Raffaele
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 127 : 92 - 107
  • [7] GB/T 17657-2013, 2013, 176572013 GBT
  • [8] GB/T 228.1-2010,, 2010, 22812010 GBT
  • [9] Cold-formed steel structures: Research review 2013-2014
    Hancock, G. J.
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (03) : 393 - 408
  • [10] Strength prediction for discontinuity regions by softened strut-and-tie model
    Hwang, SJ
    Lee, HJ
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2002, 128 (12) : 1519 - 1526