Effectiveness of visual biofeedback-guided respiratory-correlated 4D-MRI for radiotherapy guidance on the MR-linac

被引:2
作者
Keijnemans, Katrinus [1 ,2 ]
Borman, Pim [1 ]
Raaymakers, Bas [1 ]
Fast, Martin [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Radiotherapy, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
基金
荷兰研究理事会;
关键词
4D-MRI; abdominothoracic cancer; MR-linac; radiotherapy; visual biofeedback; INTERNAL LUNG MOTION; AUDIOVISUAL BIOFEEDBACK; GATED RADIOTHERAPY; TUMOR MOTION; IMPACT; CT; MANAGEMENT;
D O I
10.1002/mrm.29857
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose:<bold> </bold>Respiratory-correlated 4D-MRI may provide motion characteristics for radiotherapy but is susceptible to irregular breathing. This study investigated the effectiveness of visual biofeedback (VBF) guidance for breathing regularization during 4D-MRI acquisitions on an MR-linac. Methods:<bold> </bold>A simultaneous multislice-accelerated 4D-MRI sequence was interleaved with a one-dimensional respiratory navigator (1D-RNAV) in 10 healthy volunteers on a 1.5T Unity MR-linac (Elekta AB, Stockholm, Sweden). Volunteer-specific breathing amplitudes and periods were derived from the 1D-RNAV signal obtained during unguided 4D-MRI acquisitions. These were used for the guidance waveform, while the 1D-RNAV positions were overlayed as VBF. VBF effectiveness was quantified by calculating the change in coefficient of variation (CVdiff) for the breathing amplitude and period, the position SD of end-exhale, end-inhale and midposition locations, and the agreement between the 1D-RNAV signals and guidance waveforms. The 4D-MRI quality was assessed by quantifying amounts of missing data. Results:<bold> </bold>VBF had an average latency of 520 +/- 2 ms. VBF reduced median breathing variations by 18% to 35% (amplitude) and 29% to 57% (period). Median position SD reductions ranged from -3% to 35% (end-exhale), 29% to 38% (end-inhale), and 25% to 37% (midposition). Average differences between guidance waveforms and 1D-RNAV signals were 0.0 s (period) and +1.7 mm (amplitude). VBF also decreased the median amount of missing data by 11% and 29%. Conclusion:<bold> </bold>A VBF system was successfully implemented, and all volunteers were able to adapt to the guidance waveform. VBF during 4D-MRI acquisitions drastically reduced breathing variability but had limited effect on missing data in respiratory-correlated 4D-MRI.
引用
收藏
页码:297 / 311
页数:15
相关论文
共 40 条
[1]   ReconSocket: a low-latency raw data streaming interface for real-time MRI-guided radiotherapy [J].
Borman, P. T. S. ;
Raaymakers, B. W. ;
Glitzner, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18)
[2]   Characterization of imaging latency for real-time MRI-guided radiotherapy [J].
Borman, P. T. S. ;
Tijssen, R. H. N. ;
Bos, C. ;
Moonen, C. T. W. ;
Raaymakers, B. W. ;
Glitzner, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15)
[3]   MR-guided Gated Stereotactic Radiation Therapy Delivery for Lung, Adrenal, and Pancreatic Tumors: A Geometric Analysis [J].
de Koste, John R. van Sornsen ;
Palacios, Miguel A. ;
Bruynzeel, Anna M. E. ;
Slotman, Ben J. ;
Senan, Suresh ;
Lagerwaard, Frank J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (04) :858-866
[4]   The long- and short-term variability of breathing induced tumor motion in lung and liver over the course of a radiotherapy treatment [J].
Dhont, Jennifer ;
Vandemeulebroucke, Jef ;
Burghelea, Manuela ;
Poels, Kenneth ;
Depuydt, Tom ;
Van den Begin, Robbe ;
Jaudet, Cyril ;
Collen, Christine ;
Engels, Benedikt ;
Reynders, Truus ;
Boussaer, Marlies ;
Gevaert, Thierry ;
De Ridder, Mark ;
Verellen, Dirk .
RADIOTHERAPY AND ONCOLOGY, 2018, 126 (02) :339-346
[5]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[6]   Delivery of magnetic resonance-guided single-fraction stereotactic lung radiotherapy [J].
Finazzi, Tobias ;
de Koste, John R. van Sornsen ;
Palacios, Miguel A. ;
Spoelstra, Femke O. B. ;
Slotman, Berend J. ;
Haasbeek, Cornelis J. A. ;
Senan, Suresh .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 14 :17-23
[7]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97
[8]   The application of the sinusoidal model to lung cancer patient respiratory motion [J].
George, R ;
Vedam, SS ;
Chung, TD ;
Ramakrishnan, V ;
Keall, PJ .
MEDICAL PHYSICS, 2005, 32 (09) :2850-2861
[9]   Audio-visual biofeedback for respiratory-gated radiotherapy: Impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy [J].
George, Rohini ;
Chung, Theodore D. ;
Vedam, Sastry S. ;
Ramakrishnan, Viswanathan ;
Mohan, Radhe ;
Weiss, Elisabeth ;
Keall, Paul J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (03) :924-933
[10]   SPATIAL LOCALIZATION IN 2 DIMENSIONS USING NMR DESIGNER PULSES [J].
HARDY, CJ ;
CLINE, HE .
JOURNAL OF MAGNETIC RESONANCE, 1989, 82 (03) :647-654