Static couch non-coplanar arc selection optimization for lung SBRT treatment planning

被引:3
作者
Lincoln, John D. [1 ]
MacDonald, R. Lee [1 ,2 ,3 ]
Syme, Alasdair [1 ,2 ,3 ]
Thomas, Christopher G. [1 ,2 ,3 ,4 ]
机构
[1] Dalhousie Univ, Dept Phys & Atmospher Sci, Halifax, NS, Canada
[2] Dalhousie Univ, Dept Radiat Oncol, Halifax, NS, Canada
[3] Nova Scotia Hlth, Dept Med Phys, Halifax, NS, Canada
[4] Dalhousie Univ, Dept Radiol, Halifax, NS, Canada
关键词
non-coplanar; radiotherapy; optimization; SBRT; SABR; extra-cranial; stereotactic; INTENSITY-MODULATED RADIOTHERAPY; BODY RADIATION-THERAPY; IMRT; CANCER; CONFORMITY;
D O I
10.1088/1361-6560/ace23f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Non-coplanar arc geometry optimizations that take advantage of beam's eye view (BEV) geometric overlap information have been proven to reduce dose to healthy organs-at-risk (OARs). Recently, a metric called mean arc distance (MAD) has been developed that quantifies the arc geometry sampling of 4 & pi; space. The purpose of this research is to combine improved BEV overlap information with MAD to generate static couch lung stereotactic body radiotherapy (SBRT) treatment plans deliverable on a C-arm linear accelerator. Approach. An algorithm utilizing the Moller-Trumbore ray-triangle intersection method was employed to compute a cost surrogate for dose to overlapping OARs using distances interpolated onto a PDD. Cost was combined with MAD for 100 000 random combinations of arc trajectories. A pathfinding algorithm for arc selection was created, balancing the contributions of MAD and 4 & pi; cost for the final trajectory. This methodology was evaluated for 18 lung SBRT patients. Cases were also planned with arcs from a clinical treatment template protocol for dosimetric and plan quality comparison. Results were evaluated using dose constraints in the context of RTOG0915. Main results. Five of six OARs had maximum dose reductions when planned with the arc trajectory optimization algorithm. Significant maximum dose reductions were found for esophagus (7.41 & PLUSMN; 0.91 Gy, p = 0.00019), trachea (5.56 & PLUSMN; 1.55 Gy, p = 0.0025), spinal cord (2.87 & PLUSMN; 1.13 Gy, p = 0.039), large bronchus (3.47 & PLUSMN; 1.49 Gy, p = 0.0075), and aorta (3.13 & PLUSMN; 0.99 Gy, p = 0.012). Mean dose to contralateral lung was also significantly reduced (0.50 & PLUSMN; 0.06 Gy, p = 0.00019). There were two significant increases in OAR doses: mean dose to ipsilateral lung (0.40 & PLUSMN; 0.09, p = 0.00086) and V5(Gy) to ipsilateral lung (1.95 & PLUSMN; 0.70%, p = 0.011). Paddick conformity index increased by 0.03 & PLUSMN; 0.02 (p = 0.14), remaining below a limit of 1.2 for both techniques. Significance. Static couch non-coplanar optimization yielded maximum dose reductions to OARs while maintaining target conformity for lung SBRT.
引用
收藏
页数:16
相关论文
共 32 条
[1]   QUANTITATIVE ANALYSES OF NORMAL TISSUE EFFECTS IN THE CLINIC (QUANTEC): AN INTRODUCTION TO THE SCIENTIFIC ISSUES [J].
Bentzen, Soren M. ;
Constine, Louis S. ;
Deasy, Joseph O. ;
Eisbruch, Avi ;
Jackson, Andrew ;
Marks, Lawrence B. ;
Ten Haken, Randall K. ;
Yorke, Ellen D. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03) :S3-S9
[2]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[3]   Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations [J].
Bush, K. ;
Gagne, I. M. ;
Zavgorodni, S. ;
Ansbacher, W. ;
Beckham, W. .
MEDICAL PHYSICS, 2011, 38 (04) :2208-2221
[4]  
Cignoni P., 2008, Eurographics Italian chapter conference, P129, DOI DOI 10.2312/LOCALCHAPTEREVENTS/ITALCHAP/ITALIANCHAPCONF2008/129-136
[5]   4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung Tumors [J].
Dong, Peng ;
Lee, Percy ;
Ruan, Dan ;
Long, Troy ;
Romeijn, Edwin ;
Low, Daniel A. ;
Kupelian, Patrick ;
Abraham, John ;
Yang, Yingli ;
Sheng, Ke .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (03) :407-413
[6]   4π Non-Coplanar Liver SBRT: A Novel Delivery Technique [J].
Dong, Peng ;
Lee, Percy ;
Ruan, Dan ;
Long, Troy ;
Romeijn, Edwin ;
Yang, Yingli ;
Low, Daniel ;
Kupelian, Patrick ;
Sheng, Ke .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (05) :1360-1366
[7]   Part 1: Optimization and evaluation of dynamic trajectory radiotherapy [J].
Fix, Michael K. ;
Frei, Daniel ;
Volken, Werner ;
Terribilini, Dario ;
Mueller, Silvan ;
Elicin, Olgun ;
Hemmatazad, Hossein ;
Aebersold, Daniel M. ;
Manser, Peter .
MEDICAL PHYSICS, 2018, 45 (09) :4201-4212
[8]  
Guckenberger M, 2007, STRAHLENTHER ONKOL, V183, P57, DOI 10.1007/s00066-007-1631-3
[9]   Rectal dose reduction with IMRT for prostate radiotherapy [J].
Hardcastle, N. ;
Davies, A. ;
Foo, K. ;
Miller, A. ;
Metcalfe, P. E. .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2010, 54 (03) :235-248
[10]   Comparison of anatomically informed class solution template trajectories with patient-specific trajectories for stereotactic radiosurgery and radiotherapy [J].
Lincoln, John David ;
MacDonald, Robert Lee ;
Little, Brian ;
Syme, Alasdair ;
Thomas, Christopher Grant .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (11)