Smart Mattress Based on Multipoint Fiber Bragg Gratings for Respiratory Rate Monitoring

被引:19
作者
De Tommasi, Francesca [1 ]
Lo Presti, Daniela [1 ]
Caponero, Michele Arturo [2 ]
Carassiti, Massimiliano [3 ]
Schena, Emiliano [1 ]
Massaroni, Carlo [1 ]
机构
[1] Univ Campus Biomed Roma, Dept Fac Engn, Unit Measurements & Biomed Instrumentat, I-00128 Rome, Italy
[2] ENEA Res Ctr Frascati, I-00044 Rome, Italy
[3] Univ Campus Biomed Roma, Sch Med, Unit Anesthesia Intens Care & Pain Management, I-00128 Rome, Italy
关键词
Fiber Bragg grating sensors (FBGs); multipoint monitoring; respiratory rate (RR); smart mattress; unobtrusive monitoring; VITAL SIGNS; BREATHING DISORDERS; SLEEP-APNEA; SYSTEM; HEART; TECHNOLOGY; MOVEMENTS; FBG;
D O I
10.1109/TIM.2022.3232615
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
monitoring of respiratory rate (RR) is of great importance in people suffering from sleep-related breathing disorders (SBDs). Instrumented mattresses are gaining the atten-tion of several research groups to monitor this vital sign. Among the existing sensing techniques, fiber Bragg grating sensors (FBGs) show promise in this arena. In this article, we presented a novel FBG-based smart mattress to monitor RR over time. The proposed measuring system consisted of 13 sensing elements (SEs) based on FBGs encapsulated in soft biocompatible rubber, totally embedded in multiple silicone layers. Compactness, robustness, and user comfort are the main advantages of our solution. The mattress size and the arrangement of the 13 SEs were chosen to allow monitoring subjects with different anthropometric parame-ters and taking up different sleeping postures. Before the overall system integration, each SE was subjected to static and dynamic metrological characterization, a process often overlooked in fiber-optic-based mattresses. Results showed a mean sensitivity to force equal to 14 pm middot N-1 and a mean percentage hysteresis error always lower than 18%. The feasibility assessment of the system in RR monitoring was carried out on five healthy volunteers taking up common sleeping postures (i.e., supine-S-, right side-RS-, left side-LS-, and prone-P-) under two breathing conditions (i.e., quiet breathing-QB-, and tachypnea-T-). RR esti-mation showed a mean absolute error (MAE) always lower than 0.65 breaths/min. The promising findings proved the capability of our smart mattress in monitoring RR over time, encouraging the investigation of its performance in real-world scenarios.
引用
收藏
页数:10
相关论文
共 58 条
  • [1] Obstructive sleep apnea and depression
    Baran, AS
    Richert, AC
    [J]. CNS SPECTRUMS, 2003, 8 (02) : 128 - 134
  • [2] Bekele A., 2018, PROC IEEE INT S MED, P1
  • [3] Ben-Ari J., 2010, Journal of Medical Engineering & Technology, V34, P393, DOI 10.3109/03091902.2010.503308
  • [4] Bloch K E, 1997, Technol Health Care, V5, P285
  • [5] Vital Signs Monitoring with Wearable Sensors in High-risk Surgical Patients A Clinical Validation Study
    Breteler, Martine J. M.
    KleinJan, Eline J.
    Dohmen, Daan A. J.
    Leenen, Luke P. H.
    van Hillegersberg, Richard
    Ruurda, Jelle P.
    van Loon, Kim
    Blokhuis, Taco J.
    Kalkman, Cor J.
    [J]. ANESTHESIOLOGY, 2020, 132 (03) : 424 - 439
  • [6] Contact-free measurement of heart rate, respiration rate, and body movements during sleep
    Brink, Mark
    Mueller, Christopher H.
    Schierz, Christoph
    [J]. BEHAVIOR RESEARCH METHODS, 2006, 38 (03) : 511 - 521
  • [7] Ambient and unobtrusive cardiorespiratory monitoring techniques
    Brüser, Christoph
    Antink, Christoph Hoog
    Wartzek, Tobias
    Walter, Marian
    Leonhardt, Steffen
    [J]. IEEE Reviews in Biomedical Engineering, 2015, 8 : 30 - 43
  • [8] Textile-Based Pressure Sensing Matrix for In-Bed Monitoring of Subject Sleeping Posture and Breathing Activity
    Carbonaro, Nicola
    Laurino, Marco
    Arcarisi, Lucia
    Menicucci, Danilo
    Gemignani, Angelo
    Tognetti, Alessandro
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (06):
  • [9] An Enhanced Sensing Application Based on a Flexible Projected Capacitive-Sensing Mattress
    Chang, Wen-Ying
    Chen, Chi-Chun
    Chang, Chih-Cheng
    Yang, Chin-Lung
    [J]. SENSORS, 2014, 14 (04) : 6922 - 6937
  • [10] Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements
    Chee, Y
    Han, J
    Youn, J
    Park, K
    [J]. PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) : 413 - 422